• 제목/요약/키워드: energy change

검색결과 6,355건 처리시간 0.033초

거주자 참여형 에너지 절감 활동 효과 연구 -S대학 기숙사 거주 학생을 대상으로 한 에너지피드백 활동을 중심으로- (A Study on the Effects of Resident Participation in Energy Saving Activities)

  • 정혜진;송해
    • 한국기후변화학회지
    • /
    • 제9권3호
    • /
    • pp.253-261
    • /
    • 2018
  • As user-involved energy saving activities have become important in recent years, many forms of energy feedback experiments have been conducted. We conducted a study to determine if energy feedback activities affect energy saving for students living in dormitories at a university in Seoul. In particular, smart plugs were used for efficient research and quantitative performance measurements, and the extent of the impact of competition and rewards on participant energy saving behavior was further analyzed. The main findings of this study are as follows. First, the power usage of groups using smart plugs was lower than that of those without them. Second, energy feedback delivered to smart plug users did not have a significant impact on reduction of electric power consumption. Third, competition and compensation strategies had additional effects in reducing power usage for smart plug users. As a result, methods to deliver energy feedback more effectively as ICT technologies develop and efficient energy activities using IoT technologies can be expected to spread widely in the future.

상변화물질(PCM)을 이용한 열교환기용 동파방지밸브에 관한 실험적 연구 (An Experimental Study on the Freezing Protection Valve Using Phase Change Material(PCM) for the Heat Exchanger)

  • 윤재호;김종하;정순영;양윤섭;김성현;송덕용
    • 한국태양에너지학회 논문집
    • /
    • 제32권6호
    • /
    • pp.127-133
    • /
    • 2012
  • This paper is an experimental study on the freezing protection valve used for solar water heating, air-conditioning systems, and plumbing systems. When the phase change occurs from liquid to solid, most of the substances except water volumetrically shrink. And referred to as PCM(Phase Change Material) a substance with such properties, the phase change temperature varies depending on the material. To prevent the freezing of the plumbing system, such as air-conditioning system in the winter season, we developed a several types of freezing protection valve using PCM whose freezing temperature are $2-4^{\circ}C$. The working principle of the freezing protection valve is that the fluid inside the pipe is released to prevent the system-collapse when fluid temperature reaches the freezing temperature of the PCM. And then the valve is closed and returned to the original position automatically when the temperature of the operating fluid rises. In this paper, the operating temperatures, discharge flow rate and the response characteristics of the valve during the operation are tested and investigated. From the results of this research the freezing protection valves employing PCM are expected to be commercialized in the near future.

소형지주에 충돌하는 차량의 속도변화 산정방법과 영향인자 (Calculation Method and Influence Factor for Speed Change of a Vehicle Impacting Small Sign Post)

  • 고만기;김기동;전성민;성정곤
    • 한국방재학회 논문집
    • /
    • 제8권4호
    • /
    • pp.47-52
    • /
    • 2008
  • Breakaway 단부장치 설계에 중요한 요소가 충돌 차량의 속도변화이다. 이는 충돌실험이나 3차원 유한요소 해석을 통해서 구할 수 있으나 에너지와 운동량 보존의 법칙을 이용하여 비교적 간단하게 계산할 수도 있다. 본 논문에서는 에너지와 운동량 보존의 법칙에 기초한 지주와 소형차 충돌 시 속도변화를 계산하는 식을 유도하였다. 이를 이용한 민감도 분석을 통하여 지주 단부의 분리하중, 파괴에너지, 차량의 강도 와 충돌속도가 소형지주에 충돌하는 차량의 속도변화에 미치는 영향을 파악하였다. 지주 단부가 기초에 고정된 정도를 나타내는 분리력 및 분리파괴에너지(Breakaway Fracture Energy)가 클수록 속도변화가 크고 충돌속도의 크기가 작을수록 속도변화가 크게 나타났다.

비말 가림막과 휴대형 공기청정기 사용에 의한 대화 중 비말 및 공기전파 저감 효과 (Effectiveness of droplet protective screens and portable air purifiers against droplet and airborne transmission during conversation)

  • 허지은;신동호;조희주;박현설;조윤행
    • 한국입자에어로졸학회지
    • /
    • 제18권4호
    • /
    • pp.87-95
    • /
    • 2022
  • Currently, droplet protective screens (DPSs) are used to prevent the spread of respiratory diseases. As virus particles can maintain their infective in indoor environments, recent studies have investigated the risk of airborne transmission. However, the ability of DPSs to block airborne transmission has not been verified yet. In this study, the preventive ability of DPSs against droplet and airborne transmission was evaluated. Moreover, the effectiveness of a Portable air purifier (PAP) was investigated. According to results, in a simulated room where an infectious person spoke, the DPS blocked more than 90% of the micron-sized droplets (with a diameter larger than 1 ㎛) transmitted to the front of the infectious person. However, sub-micron droplets (with a diameter smaller than 1 ㎛) passed through the DPS and spread in a room. However, the PAP reduced the amount of both micron and sub-micron droplets transmitted to the front of the infectious person. When the PAP airflow direction was set from the DPS surface to the free space near the infectious person, improved prevention against droplet and airborne transmission was recorded. However, airborne transmission was accelerated when the PAP airflow direction was set from the free space to the DPS surface.

압축비에 의한 엔진 출력 변화 특성 (The Compression Ratio Change Characteristics of Engine Horse Power Characteristics)

  • 양현수;임주헌
    • 대한안전경영과학회지
    • /
    • 제10권2호
    • /
    • pp.85-94
    • /
    • 2008
  • The object of this study is to investigate the penetration characteristics according to the change of stacking sequences and curvature radius in the composite laminated shell. They are staked to [02/902]S and [0/902/0]s, their interlaminar number are two and four. We are manufactured to composite laminated shells with various curvature radius. Curvature radius of composite shell is 100, 150, 200mm and ${\infty}$(it's meaning flat-plate). In general, kinetic energy after impact-kinetic energy before impact increased linearly in all specimens. Absorbed energy increased linearly as the curvature increased, and absorbed energy of [02/902]S specimen, which is small interlaminar number, was higher than [0/902/0]s specimen.

Stroke 변화가 Four-Valve SI 기관 실린더내 난류 운동에너지에 미치는 영향 (Effects of Stroke Change on Turbulent Kinetic Energy for the In-Cylinder Flow of a Four-Valve SI Engine)

  • 유성출
    • 한국가시화정보학회지
    • /
    • 제9권4호
    • /
    • pp.16-21
    • /
    • 2011
  • The effects of stroke change on turbulent kinetic energy for the in-cylinder flow of a four-valve SI engine were studied. For this study, the same intake manifold, head, cylinder, and the piston were used to examine turbulence characteristics in two different strokes. In-cylinder flow measurements were conducted using three dimensional LDV system. The measurement method, which simultaneously collects 3-D velocity data, allowed a evaluation of turbulent kinetic energy inside a cylinder. High levels of turbulent kinetic energy were found in regions of high shear flow, attributed to the collisions of intake flows. These specific results support the more general conclusion that the inlet conditions play the dominant role in the generation of the turbulence fields during the intake stroke. However, in the absence of two counter rotating vortices, this intake generated turbulent kinetic energy continues to decrease but at a much faster rate.

Reduction of Energy and Food Security in DPRK due to Deforestation

  • SHIN, Eunsoo Justin;Ahn, Ji Whan
    • 에너지공학
    • /
    • 제27권3호
    • /
    • pp.63-67
    • /
    • 2018
  • The Democratic People's Republic of Korea, or the DPRK, is one of the poorest country in world facing chronic economic, energy and food security issues. Prolonged improper management of economic and natural resources has led to extreme poverty, malnutrition and critically vulnerability to nature's forces. Presistent deforestation and forest degradation in the DPRK has national and global consequences which has attracted attention from international community, whose offering financial and technical assistance for targeted interventions. Through REDD+ programs, the DPRK has the opportunity to establish its credentials as a responsible nation while improving the quality of life of its population. This study offers an enabling context under which suitable climate change action related to forestry can be identified and implemented in the DPRK.

탄소세 부과에 따른 국내 에너지-경제-환경(3E) 변화 분석 및 예측을 위한 시스템다이내믹스 모델 개발 (System Dynamics Model for Analyzing and Forecasting the National Energy-Economy-Environment(3E) Changes under Levying of Carbon Tax)

  • 송재호;정석재;김경섭;박진원
    • 한국시스템다이내믹스연구
    • /
    • 제7권2호
    • /
    • pp.149-170
    • /
    • 2006
  • In this paper, an energy-economy-environment dynamic simulation model was developed to using system dynamics methodology. It describes current energy-economy-environment systems and forecasts changes caused by levying of carbon tax. The model is composed of three modules: an energy module, an economic module and an environmental module. Variables are interrelated in each module, and three modules are linked by several linkage variables. Setting up the linkage variables is an important factor for the composition of the model. The simulation result shows a change of the national GDP, usage of energy, and $CO_2$ emissions under levying and reinvestment of carbon tax considering various scenarios for the charging cost.

  • PDF

차체구조용 박육부재의 단면형상변화에 따른 에너지흡수 특성 (Energy Absorbing Characteristics of Thin-Walled Members for Vehicles Having Various Section Shapes)

  • 차천석;정진오;이길성;백경윤;양인영
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.177-182
    • /
    • 2003
  • The front-end side members of automobiles absorb most of the energy in a case of front-end collision. The front-end side members are required to have a high stiffness together with easiness to collapse sequentially to absorb more impact energy. The axial static collapse test (5mm/min) was conducted by using UTM for form different types of members which have different cross section shapes; single hat, single cap, double cap, and double hat. The single hat shaped section member has the typical standard section, which the double hat shape section has a symmetry in the center to have more stiffness. As a result of the test, the energy absorbing characteristic was analyzed for different section shapes. It turned out that the change of section shape influence the absorbing energy, the mean collapse load and the maximum collapse load, and the relation between the change of section shape and the collapse mode.

수치해석과 실험을 통한 Can type container 내부 상변화 물질의 열유체적 특성분석 (Numerical analysis of the thermal fluid characteristics of phase change material in can type container)

  • 허승민;현수웅;정희준;신동호
    • 한국가시화정보학회지
    • /
    • 제21권2호
    • /
    • pp.63-71
    • /
    • 2023
  • Energy storage and distribution technologies are emerging as important factors as research on renewable energy continues. Analyzing the thermal flow of phase change material inside a latent heat storage device and to predict the phase change time is an important part for improvement of thermal performance. However, most of the current research is based on the trial-and-error experimental investigation to measure the phase change time. Therefore, in this study, a can-type phase change material container was designed, and the numerical method for analyzing the thermal flow of phase change material was established and validated. The error rate of the phase change time between the numerical and experimental results was within 5%, which proves its reliability. As a result, the phase change finishing times were found to be 78 minutes with inlet fluid temperature of 80℃ during charging process, and 126 minutes with inlet fluid temperature of 9℃ during discharging process.