• 제목/요약/키워드: end bearing

검색결과 426건 처리시간 0.025초

보 단부 부착시험체에 의한 높은마디 철근의 부착성능 (Evaluate Bond strength of high Relative Rib Area Bars Using Beam-end test specimens)

  • 서동민;양승열;홍기섭;최완철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.112-115
    • /
    • 2004
  • Bond between reinforcing bar and surrounding concrete is supposed to transfer load safely in the process of design of reinforced concrete structures. Bond failure of reinforcing bar generally take place by splitting of the concrete cover as bond force between concrete and reinforcing bars exceeds the confinement of the concrete cover and reinforcement. However, the confinement force has a limitation. Thus, the only variable is the bearing angle corresponding to the change of bond force. Higher rib height bars possessing higher shearing resistance can maintain higher bearing angle and higher splitting resistance when bars are highly confined, and consequently higher bond strength, than lower rib higher bars. In this study, from the evaluate bond strength of high Relative Rib Area Bars Using beam-end test specimens are compared with the current provisions for development of reinforcement, and the improved design method of bond strength is proposed.

  • PDF

Behavior of polymer columns in soft clayey soil: A preliminary study

  • Arasan, Seracettin;Akbulut, Rahim Kagan;Isik, Fatih;Bagherinia, Majid;Zaimoglu, Ahmet Sahin
    • Geomechanics and Engineering
    • /
    • 제10권1호
    • /
    • pp.95-107
    • /
    • 2016
  • Deep soil mixing with cement and cement-lime mixtures has been widely used for decades to improve the strength of soils. In this study, small-scale laboratory model tests of polymer columns in soft clayey soil were conducted to evaluate the feasibility of using various polymeric compounds as binders in deep soil mixing. Floating and end bearing polymer columns were used to examine the load-settlement relationship of improved soft clayey soils for various area replacement ratios. The results indicate that polymer columns show good promise for use in deep mixing applications.

Investigations on critical speed suppressing by using electromagnetic actuators

  • Mahfoud, Jarir;Der Hagopian, Johan
    • Smart Structures and Systems
    • /
    • 제9권4호
    • /
    • pp.303-311
    • /
    • 2012
  • The possibility of suppressing critical speeds by using electromagnetic actuators (EMAs) is assessed experimentally in this paper. The system studied is composed of a horizontal flexible shaft supported by two ball bearings at one end and one roller bearing that is located in a squirrel cage at the other end. Four identical EMAs supplied with constant current are utilized. The EMAs associated to the squirrel cage constitutes the hybrid bearing. Results obtained, show that the constant current, when applied to the EMAs, produces a shift of the first critical speed toward lower values. Moreover, the application of constant current for a speed interval around the critical speed enables a smooth run-up or run-down without crossing any resonance.

가변선단재하판을 이용한 양방향말뚝재하시험의 모형실험 (Model Test of O-Cell Pile Load Test with Variable End Plate)

  • 주용선;김낙경;김성규;김웅진;박종식
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.476-481
    • /
    • 2009
  • Bi-directional load test is one of O-cell tests. The O-cell test is a system which may be used for performing static load tests on cast in situ reinforced concrete bored piles. The technique was devised and developed by Osterberg of Northwestern University(USA) and has been in use around the world. The principle of the method is that an O-cell is installed in a cast in situ bored pile base. Once the pile concrete reaches its design strength the cell is connected to an hydraulic pump and pressured. Pressurization causes the cell to expand, developing an upward force on the section of pile above the cell loads, pile movements and strains within the pile then enable the capacity of the pile and its load settlement curves to be ascertained. The O-cell pile load test with variable end plate is operated on second steps - the first step is to confirming end bearing capacity with variable end plate and the second step is similar to the conventional O-cell test. In the study, To calculate ultimate capacity of bi-directional load test using model with the pile with variable end plate O-cell.

  • PDF

Coupled testing-modeling approach to ultimate state computation of steel structure with connections for statics and dynamics

  • Imamovic, Ismar;Ibrahimbegovic, Adnan;Mesic, Esad
    • Coupled systems mechanics
    • /
    • 제7권5호
    • /
    • pp.555-581
    • /
    • 2018
  • The moment-resistant steel frames are frequently used as a load-bearing structure of buildings. Global response of a moment-resistant frame structure strongly depends on connections behavior, which can significantly influence the response and load-bearing capacity of a steel frame structure. The analysis of a steel frame with included joints behavior is the main focus of this work. In particular, we analyze the behavior of two connection types through experimental tests, and we propose numerical beam model capable of representing connection behavior. The six experimental tests, under monotonic and cyclic loading, are performed for two different types of structural connections: end plate connection with an extended plate and end plate connection. The proposed damage-plasticity model of Reissner beam is able to capture both hardening and softening response under monotonic and cyclic loading. This model has 18 constitutive parameters, whose identification requires an elaborate procedure, which we illustrate in this work. We also present appropriate loading program and arrangement of measuring equipment, which is crucial for successful identification of constitutive parameters. Finally, throughout several practical examples, we illustrate that the steel structure connections are very important for correct prediction of the global steel frame structure response.

Tilting 상태인 테이퍼 로울러의 탄성유체윤활 해석 (Elastohydrodynamic Lubrication Analysis of a Tilted Tapered Roller)

  • 박태조
    • Tribology and Lubricants
    • /
    • 제31권4호
    • /
    • pp.177-182
    • /
    • 2015
  • Tapered roller bearings are widely used in equipment where high combined thrust and radial loads are experienced. A certain amount of tilting between the tapered rollers and the races always occurs because of bending moment load conditions and shaft deflection. It is now well understood that a coherent elastohydrodynamic lubrication (EHL) film separates the rollers and races. In spite of extensive study on EHL problems for over half a century, relatively few studies have focused on the finite line contacts problem. This study presents a complete numerical analysis of the effects of roller tilting on the EHL characteristics in a tapered roller bearing. We systematically analyze this highly nonlinear problem using finite differences with fully non-uniform grids and the Newton-Raphson method. Detailed EHL pressure distributions and film shapes are presented under moderate loads and material parameters. A very small roller tilting significantly affects the pressure distributions and film shapes near both ends of the roller. Moreover, the effect of tilting on the EHL characteristics at the small end is much greater than that at the large end. Therefore, in designing optimum profiles for tapered roller bearings, the profile radius should be larger at the small end.

크레인 거더의 피로균열에 관한 실험적 연구(I) -피로균열의 발생과 진전- (Experimental Study on Fatigue Crack in Welded Crane Runway Girders(I) -Initiation and Propagation of Fatigue Crack-)

  • 임성우;김진호;장인화
    • 한국강구조학회 논문집
    • /
    • 제9권2호통권31호
    • /
    • pp.237-248
    • /
    • 1997
  • 크레인 주행거더에서 빈번히 발생되는3 종류의 균열을 재현하기 위해서 거더 길이 640 mm, 높이 600 mm, 폭 300 mm의 시험체 2기를 제작하여 피로실험을 수행하였다. 시험체의 균열은 재하점 부근과 가세트 단부 및 하부플랜지와 웨브의 모살용접부에서 발생하였다. 재하점 근방의 균열은 수직보강재가 위치한 상부플랜지와 웨브 사이의 모살용접부에서 발생해서 웨브의 대각선 방향으로 진전하였다. 또한 하부플랜지 종비드에서 발생된 균열은 주행거더방향에 수직으로 성장하였다. 크레인 주행거더의 각 부위의 피로등급은 JSSC 피로설계지침의 피로등급과 비교해 보면, 재하점 근방의 모살용접부는 E 등급, 가세트 단부는 G 또는 H 등급, 하부플랜지 종비드 부위는 D 등급 정도로 나타났다. 가세트 단부와 종비드 부위는 피로설계지침과 잘 일치하고 있음을 알 수 있다.

  • PDF

DCPT를 이용한 풍화대 소켓 현장타설말뚝의 설계도표 개발에 관한 연구 (A Study on the Development of Design Chart for Drilled Shaft Socketed into Weathered Zone Using DCPT (Driving Cone Penetrometer Test))

  • 정성민;권오성;이종성;이민희;최용규
    • 한국지반공학회논문집
    • /
    • 제26권5호
    • /
    • pp.5-13
    • /
    • 2010
  • 국내 풍화대 지반에 적용가능한 설계도표를 작성하기 위하여 2개소 현장에서 총 6개의 양방향고유양말뚝재하시험 및 하중전이시험을 수행하였으며, 또한 각각 위치에서는 한국형타격콘관입시험 (DCPT)을 수행하였다. 말뚝재하시혐의 결과로부터 심도별 최대단위선단지지력올 분석하였으며 DCPT 결과를 이용하여 이들의 상관성을 분석하였다. 토사(사질토, 점토)지반에서는 최대단위주변마찰력과 DCPT의 상관성이 매우 낮게 나타났으나 풍화대지반에서는 최대단위주변마찰력 / 최대단위선단지지력과 DCPT의 관계에서는 상관계수가 0.70이상으로 높게 나타났다.

현장타설말뚝의 정재하시험에 의한 지지력과 이론식에 의한 지지력과의 비교 (The Bearing Capacity Comparison of Drilled Shaft by the Static Load Test and the Suggested Bearing Capacity Formulas)

  • 천병식;김원철;최용규;서덕동
    • 한국지반공학회논문집
    • /
    • 제19권2호
    • /
    • pp.237-246
    • /
    • 2003
  • 항타말뚝은 진동과 소음같은 환경적인 문제점이 있다. 특히 대상 토질이 자갈, 호박돌, 풍화암으로 구성되어있다면 항타말뚝의 적용은 불가능하기 때문에 우리나라에서는 현장말뚝의 적용이 증가하고 있는 추세이다. 일반적으로 이론적인 공식에 의한 현장타설말뚝의 지지력은 과소하게 산정되는 것으로 알려져 있다. 본 연구에서는 기존에 제안된 국내외 지지력 산정식과 현장시험을 통한 실측데이터를 비교하기위해 광안대로와 수영 3호교의 암반에 근입된 현장 타설말뚝에 대한 정재하시험을 수행하였으며, 현장타설말뚝의 주변마찰력을 측정하기 위하여 변위계를 설치하였다. 현장시험을 통한 현장타설말뚝의 거동은 반복하중 재하시 완전한 탄성거동을 보였으므로 이는 실제말뚝의 극한지지력에 도달하지 못하였음을 입증한다. 이때 측정된 말뚝의 지지력이 이론식에 의하여 산정된 지지력보다 크게 산정되었다. 또한 실험에서 측정된 결과에 의하면 현장타설말뚝의 주된 지지력이 선단지지력이 아닌 주변마찰저항에 의한 것이라는 것을 보였다. 그리고 이와같은 결과에 의거하여 현장타설말뚝의 설계에 대한 몇가지 제안들을 도출하였다.