• 제목/요약/키워드: electronic needle

검색결과 172건 처리시간 0.05초

Acupuncture for Symptomatic Rotator Cuff Disease: A Systematic Review and Meta-Analysis

  • Choi, Seoyoung;Lee, Jisun;Lee, Seunghoon;Yang, Gi Young;Kim, Kun Hyung
    • Journal of Acupuncture Research
    • /
    • 제38권1호
    • /
    • pp.20-31
    • /
    • 2021
  • The objective was to evaluate the effectiveness and safety of acupuncture for patients with rotator cuff diseases. There were 12 electronic databases and 3 trial registries searched up to November 30th, 2019. All randomized trials were eligible, regardless of language, date of publication, or settings. The primary outcomes were pain, shoulder function, and proportion of improved participants assessed within 12 weeks of randomization of the trial. The Cochrane risk of bias for the studies was assessed. Effects sizes were presented as a risk ratio, mean difference, or standardized mean difference with a 95% confidence intervals. Grading of Recommendations Assessment, Development and Evaluation approach was adopted to rate certainty of evidence. Of the 3,686 records screened, 28 randomized trials (2,216 participants) were included in this review. The types of acupuncture included manual acupuncture, dry needling, electroacupuncture, acupotomy, warm needle acupuncture, and fire needle acupuncture. All of the studies had an unclear or high risk of bias related to more than 1 domain. Significant benefits of acupuncture in terms of pain and shoulder function were observed in all comparisons, however, the proportion of improved participants was not described in 2 comparisons. There was substantial heterogeneity among meta-analyzed trials. No serious harm was observed. For primary outcomes, the overall certainty of evidence was very low. There was very low certainty of evidence for the benefits of acupuncture for patients with rotator cuff diseases. The safety of acupuncture remains unclear due to the incompleteness of reporting. Future well-designed randomized trials with transparent reporting are required.

Adverse effects following dental local anesthesia: a literature review

  • Ho, Jean-Pierre T.F.;van Riet, Tom C.T.;Afrian, Youssef;Chin Jen Sem, Kevin T.H.;Spijker, Rene;de Lange, Jan;Lindeboom, Jerome A.
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제21권6호
    • /
    • pp.507-525
    • /
    • 2021
  • Local anesthesia is indispensable in dentistry. Worldwide, millions of local anesthetic injections are administered annually, and are generally considered safe invasive procedures. However, adverse effects are possible, of which dentists should be aware of. This scoping review aimed to provide an extensive overview of the reported literature on the adverse effects of dental local anesthesia. The types of papers, what is reported, and how they are reported were reviewed. Additionally, the incidence and duration of adverse effects and factors influencing their occurrence were also reviewed. An electronic search for relevant articles was performed in PubMed and Embase databases from inception to January 2, 2020. The titles and abstracts were independently screened by two reviewers. The analysis was narrative, and no meta-analysis was performed. This study included 78 articles. Ocular and neurological adverse effects, allergies, hematomas, needle breakage, tissue necrosis, blanching, jaw ankylosis, osteomyelitis, and isolated atrial fibrillation have been described. Multiple adverse effects of dental local anesthesia have been reported in the literature. The results were heterogeneous, and detailed descriptions of the related procedures were lacking. Vital information concerning adverse effects, such as the dosage or type of anesthetic solution, or the type of needle used, was frequently missing. Therefore, high-quality research on this topic is needed. Finally, the adverse effects that are rarely encountered in real-world general practice are overrepresented in the literature.

erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구 (erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus)

  • 장한솔;정우령;문정현;최성경;성원석;황민섭;이승덕;김경호;윤종화;김은정
    • 대한한의학회지
    • /
    • 제44권1호
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

MOCVD 방법에 의한 Si 기판위 GaN 나노선의 성장 (GaN Nanowire Growth on Si Substrate by Utilizing MOCVD Methods)

  • 우시관;신대근;오병성;이형규
    • 한국전기전자재료학회논문지
    • /
    • 제23권11호
    • /
    • pp.848-853
    • /
    • 2010
  • We have grown GaN nanowires by the low pressure MOCVD method on Ni deposited oxidized Si surface and have established optimum conditions by observing surface microstructure and its photoluminescence. Optimum growth temperature of $880^{\circ}C$, growth time of 30 min, TMG source flow rate of 10 sccm have resulted in dense nanowires on the surface, however further increase of growth time or TMG flow rate has not increased the length of nanowire but has formed nanocrystals. On the contrary, the increase of ammonia flow has increased the length of nanowires and the coverage of nanowire over the surface. The shape of nanowire is needle-like with a Ni droplet at its tip; the length is tens of micron with more than 40 nm in diameter. Low temperature photoluminescence obtained from the sample at optimum growth condition has revealed several peaks related to exciton decay near band-edge, but does not show any characteristic originated from one dimensional quantum confinement. Strong and broad luminescence at 2.2 eV is observed from dense nanowire samples and this suggests that the broad band is related to e-h recombination at the surface state in a nanowire. The current result is implemented to the nanowire device fabrication by nanowire bridging between micro-patterned neighboring Ni catalysis islands.

고온초전도변압기 절연설계를 위한 격벽효과와 수명특성 (V-t and Barrier Characteristics for HTS Transformer Insulation Design)

  • 정종만;백승명;김영석;곽동순;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마연구회
    • /
    • pp.61-64
    • /
    • 2003
  • In the response to an increasing demand for electrical energy, much effort aimed to develop and commercialise HTS power equipments is going on around the world. For the development, it is necessary to establish the dielectric technology in $LN_2$. Hence many types of dielectric tests should be carried out to understand the dielectric phenomena at cryogenic temperature and to gather various dielectric data. Among the many types dielectric tests, the barrier effect were conducted with the simulated electrode after analysing the insulating configuration of the pancake coil type HTS transformer. The influence of a barrier on the dielectric strength was measured according to the size and the position of the barrier. It was shown that the effectiveness, the ratio of the breakdown voltage in presence of barrier to the voltage without barrier, is highest when the barrier is placed at the needle electrode side. And the barrier effect was not depend on the electrode array. The life time to breakdown with decreasing the applied voltage was increased remarkably having wide error band but the shape parameter in Weibull distribution was almost constant.

  • PDF

코로나와 직렬아크 방전에 의해 발생한 음향신호의 분석 (Analysis of Acoustic Signals Produced by Corona and Series-arc Discharges)

  • 조향은;진창환;박대원;길경석;안창환
    • 한국전기전자재료학회논문지
    • /
    • 제25권2호
    • /
    • pp.147-152
    • /
    • 2012
  • This paper dealt with the frequency component analysis of acoustic signals produced by corona and series-arc discharges as a diagnostic technique for closed-switchboards. Corona and series-arc discharge were simulated by a needle-plane electrode and an arc generator specified in UL1699, respectively. Acoustic signal was detected by a wideband acoustic sensor with a frequency bandwidth of 4 Hz~100 kHz (-3 dB). We analyzed frequency spectrums of the acoustic signals detected in various discharge conditions. The results showed that acoustic signals mainly exist in ranges from 30 kHz to 60 kHz. From the experimental results, an acoustic detection system which consists of a constant current power supply (CCP), a low noise amplifier (LNA) and a band pass filter was designed and fabricated. The CCP separates the signal component from the DC source of acoustic sensor, and the LNA has a gain of 40 dB in ranges of 280 Hz~320 kHz. The high and the low cut-off frequency are 30 kHz and 60 kHz, respectively. We could detect corona and series-arc discharges without any interference by the acoustic detection system, and the best frequency is considered in ranges of 30 kHz~60 kHz.

Sn-3Ag-0.5Cu Solder에 대한 무전해 Ni-P층의 P함량에 따른 특성 연구 (A Study of Properties of Sn-3Ag-0.5Cu Solder Based on Phosphorous Content of Electroless Ni-P Layer)

  • 신안섭;옥대율;정기호;김민주;박창식;공진호;허철호
    • 한국전기전자재료학회논문지
    • /
    • 제23권6호
    • /
    • pp.481-486
    • /
    • 2010
  • ENIG (electroless Ni immersion gold) is one of surface finishing which has been most widely used in fine pitch SMT (surface mount technology) and BGA (ball grid array) packaging process. The reliability for package bondability is mainly affected by interfacial reaction between solder and surface finishing. Since the behavior of IMC (intermetallic compound), or the interfacial reaction between Ni and solder, affects to some product reliabilities such as solderability and bondability, understanding behavior of IMC should be important issue. Thus, we studied the properties of ENIG with P contents (9 wt% and 13 wt%), where the P contents is one of main factors in formation of IMC layer. The effect of P content was discussed using the results obtained from FE-SEM(field-emission scanning electron microscope), EPMA(electron probe micro analyzer), EDS(energy dispersive spectroscopy) and Dual-FIB(focused ion beam). Especially, we observed needle type irregular IMC layer with decreasing Ni contents under high P contents (13 wt%). Also, we found how IMC layer affects to bondability with forming continuous Kirkendall voids and thick P-rich layer.

Ag-Pd 후막도체와 솔더범프 사이의 접합특성 및 계면반응 (Characteristics of Joint Between Ag-Pd Thick Film Conductor and Solder Bump and Interfacial Reaction)

  • 김경섭;한완옥;이종남;양택진
    • 마이크로전자및패키징학회지
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2004
  • 자동차 전장품의 시험환경 조건이 엄격해짐에 따라, 전장품 개발 기술자들은 이에 부합하는 성능, 신뢰성, 비용 등을 고려한 보다 효과적인 제품 설계를 위해 노력하고 있다. 본 논문에서는 ECM 알루미나 기판의 플라즈마 세척 영향과 리플로우 후 Sn-37wt%Pb 솔더와 패드 접합부 계면에서 형성되는 금속간 화합물을 관찰하였다. 기판의 플라즈마 세척은 계면 접착력을 저해하였던 C에 의한 유기 잔류물 층이 제거되어 계면 접착력을 향상시키는 효과가 있다. 또한 AFM 분석 결과 도체 패드의 표면 거칠기는 304 nm에서 330 m로 증가하였다. 리플로우 과정에서 솔더와 TiWN/Cu 패드 계면에서 형성된 $Cu_6/Sn_5$는 리플로우 횟수가 증가할 수록 결정립의 크기도 조대화되었다. 솔더와 Ag-Pd 도체패드 계면에서는 세포질 형태의 $Ag_3Sn$화합물이 관찰되었다. $Ag_3Sn$은 지름이 약 0.1∼0.6 $\mu\textrm{m}$이며, 솔더 내부에서는 침상 모양도 관찰되었다.

  • PDF

인공 경수를 이용한 미네랄 파울링 저감에 물리적 수처리 기기들의 효과에 관한 연구 (A Study of Efficacy of Physical Water Treatment Devices for Mineral Fouling Mitigation Using Artificial Hard Water)

  • 박복춘;김선도;백병준;이동환
    • 대한기계학회논문집B
    • /
    • 제29권11호
    • /
    • pp.1229-1238
    • /
    • 2005
  • The objective of the present study was to investigate the efficacy of physical water treatment (PWT) technologies using different catalytic materials and an electronic anti-fouling device in the mitigation of mineral fouling in a once-through flow system with mini-channel heat exchanger. Effects of flow velocity and water hardness on the effectiveness of PWT technologies were experimentally studied. The artificial water hardness varied from 5.0 to 10 mo1/m$^{3}$ as CaCO$_{3}$. For 10 mo1/m$^{3}$ solution, fouling resistance reduced by 13-40$\%$ depending on flow velocity and types of PWT devices. On the other hand, fouling resistance reduced by 21-29$\%$ depending on the PWT devices for 5 mo11m3 solutions. The PWT device using alloy of Cu and Zn as catalyst (CM2) was slightly more effective than the others. SEM photographs of scale produced from the 10 mol/m$^{3}$ solution at 1.0 m/s indicated that calcium carbonate scales without PWT devices were needle-shaped aragonite, which is sticky, dense and difficult to remove. Scales with the PWT devices showed a cluster of spherical or elliptic shape crystals. Both the heat transfer test results and SEM photographs strongly support the efficacy of PWT technologies using catalytic materials and an electronic anti-fouling device in the mitigation of mineral fouling.

몰드변압기에서 용량성 프로브에 의한 부분방전 검출 기술 (Detection Technique of Partial Discharge by a Capacitive Probe in Cast-resin Transformers)

  • 정광석;박대원;차현규;차상욱;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제24권4호
    • /
    • pp.319-324
    • /
    • 2011
  • This paper dealt with a partial discharge (PD) detection method for insulation diagnosis in cast-resin transformers. To detect PD pulse, a planar-capacitive probe was designed and fabricated. The probe has no insulation problem and can be installed on cast-resin transformers even in operation since it does not connect with high voltage conductor. The PD measurement system consists of the capacitive probe, a coupling network of 100 [kHz] low-cutoff frequency, and an amplifier with a gain of 40 [dB] and a frequency bandwidth of 500 [Hz]~45 [MHz]. A plane-needle and a plane-plane electrode system were fabricated to simulate insulation defects in a cast-resin transformer. Sensitivity of the PD measurement system, which is evaluated by a standard calibrator was 0.35 [mV/pC] for positive and 0.45 [mV/pC] for negative, respectively. The PD detection by the capacitive probe was less sensitive than that by a coupling capacitor according to IEC 60270, but we could analyze the magnitude and the phase distribution of PD pulse.