• Title/Summary/Keyword: electronic floor

Search Result 77, Processing Time 0.022 seconds

Wi-Fi-Based Low-Complexity Floor Number Determination Method Based for Multistory Buildings (다층 건물을 위한 Wi-Fi 기반의 저 복잡도 층간 위치 측위 기법)

  • Shi, Jian;Li, Xiang;Jung, Honggyu;Kim, Jinoh;Shin, Yoan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.2
    • /
    • pp.149-156
    • /
    • 2014
  • Floor number determination has attracted considerable attention because many applications require accurate floor number information for providing better localization services in multistory buildings. This paper describes a Wi-Fi-based, low-complexity floor number determination method for multistory buildings. In our scheme, with the exception of floor ID and received signal strength of each WAP, detailed information on the wireless access point (WAP) coordinates is not needed. The multi-wall-floor model is used for the simulation and analysis. The simulation results show that the floor determination accuracy is nearly 100 given an adequate deployment density of WAPs on each floor. The results also show that the proposed method provides a good estimate of floor number even when only a few WAPs are implemented on each floor. Specifically, the proposed method can work under extreme conditions, i.e., where there are no WAPs on a floor.

Study on Optimal Welding Condition for Shipbuilding Steel Materials (조선강재의 최적 용접조건에 관한 연구)

  • Kim, Ok-Hwan
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.128-133
    • /
    • 2011
  • In this study, the steel material for shipbuilding(LR-A class) was used, and FCAW was taken advantage of 3G attitude and they are welded by different welding ways. As a result of analyzing wave with welding monitoring system, the stable values are obtained which are the first floor(electronic current 164~182 A, voltage 24 V), the second floor(electronic current 174~190 A, voltage 22~25 V), the third floor(electronic current 158~188 A, voltage 22~25 V), and fourth floor(electronic current 172~184 A, voltage 22~25 V), at this time, the stable wave standard deviation and changing coefficient could be obtained. When the welding testing through nondestructive inspection was analyzed know defect of welding, there was no defect of welding in A, D, E, but some porosities in B, and slag conclusion near the surface in C, because the length of arc was not accurate, and the electronic current and voltage was not stable. After observing the change of heat affect zone through micro testing, each organization of floor formed as Grain Refinement, so welding part was fine, the distance of heat affect zone is getting wider up to change the values of the electronic current and voltage. As a result of degree of hardness testing, the hardness orders were the heat affect zone(HAZ), Welding Zone(WZ), and Base Metal(BM). When the distribution of degree of hardness is observed. B is the highest degree of hardness The reason why heat effect zone is higher than welding zone and base metal, welding zone is boiled over melting point($1539^{\circ}C$) and it starts to melt after the result of analysis through metal microscope, so we can know that delicate tissue is created at the welding zone. Therefore, in order to get the optimal conditions of the welding, the proper current of the welding and voltage is needed. Furthermore the precise work of welding is required.

Prediction of the Exciting Force of Machine and the Vibration Response of Floor Using Transfer Function Method (전달함수법을 이용한 장비가진력과 바닥진동응답의 예측)

  • 김석홍;김준호;이홍기
    • Journal of KSNVE
    • /
    • v.2 no.4
    • /
    • pp.273-280
    • /
    • 1992
  • The prediction of vibration response of floor is necessary in order to check whether the floor vibration level will satisfy the allowable vibration standard of precise machinery such as electronic microscopes in semiconductor manufacturing plant before the installation of various neighboring equipment facility. In conventional vibration isolation, we were mainly interested in minimization of vibration transmissibility and stabilization of vibration isolation system. But in order to predict vibration response of floor, it is necessary to know exciting force of equipment installed on the floor and the mobility of the floor. We measured the exciting force of the dropped mass assumed as equipment and the mobility of some practical building floor using large impact hammer. And from this we predicted the vibration response of floor on which the mass dropped. This predicted vibration response of floor is compared with measured vibration response. Through upper procedure, we examined the possibility of predicting vibration response of floor from the information of exciting force of equipment and the mobility of floor.

  • PDF

A Study on the Improvement of Easy Elevator Equipment (간이용 엘리베이터 장치 개선에 관한 연구)

  • Wee, Sung-Dong;Gu, Hal-Bon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.09a
    • /
    • pp.82-88
    • /
    • 2001
  • Manufactured easy elevator can drives from the first floor to fifth floor as sequence control circuit in cause opening than existing equipment of experiment and practice, the structure of in the first implementation process are hand-worked control component with push-button, L/S and relay, it is structured a lamp to express that the door open and moving of cage by mechanical action of For/Rev motor-braker of which load. The second structure of implement process to control from the first floor to the fifth floor with the PLC elevator program can control by the sensor of hand-operated function of L/Sl~L/S5 in time that the S/Wl~S/W5 of PLC control panel operates to the For/Rev. The function of two kind process that an elevator is driven by PLC program and the sequence control relay circuit is a mechanical relay sequence control field and it is equipment apparatus of it to get appropriately the technology of For/Rev in that mechanical operating cause of a load using the PLC program. Also the wring circuit using a plug, dissembly. the circuit and the principle of component, and PLC program with the function test can be used the implementation field to the total technology theory about FA.

  • PDF

An Effective Decoding Algorithm of LDPC Codes with Lowering Error Floors (낮은 에러 플로어(error floor)를 사용한 효과적인 LDPC 복호 알고리듬)

  • Wang, Shuo-Chen;Suh, Hee-Jong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.10
    • /
    • pp.1111-1116
    • /
    • 2014
  • In this paper, in order to improve performance of LDPC codes, we propose an effective algorithm with lowering error floor of LDPC codes. This method is done by breaking trapping sets, mostly caused by an undesirable structure. This algorithm is not need to observe all the errors, only need to break the trapping sets, to effect the effectiveness. Simulation results show that its performance can be significantly improved with this decoding algorithm.

Performance Evaluation for Application of Large Capacity LPB Pack Equipped to Series Hybrid Articulated Vehicle (직렬형 하이브리드 굴절차량용 대용량 LPB 팩의 적용 및 성능 평가)

  • Lee, Kang-Won;Mok, Jai-Kyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.930-937
    • /
    • 2012
  • Newly developed Series hybrid low-floor articulated vehicle which can meet both road and railway running conditions. It has the rated driving speed of 80 km/h and three driving modes with hybrid(engine+battery) driving mode, engine driving mode, battery driving mode. The battery driving mode requires the several 10 km running without additional charging operation. The vehicle has been equipped with LPB (lithium polymer battery) pack for the series hybrid propulsion system. LPB pack consists of 168 cells (3.7 V in a cell, 80 Ah) in series, DC Circuit breaker, mechanical rack, BMS (battery management system). This paper has shown the design process of LPB pack and application to the vehicle. Driving results in the road was successful to be satisfied with the requirement of the series hybrid vehicle.

Development of an Automated Indoor Floor Finish Robot Platform (건축 내부 바닥 미장 자동화 로봇 플랫폼 개발)

  • Ji-Youn Moon;Dong-Ju Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.5
    • /
    • pp.853-858
    • /
    • 2023
  • Various types of robots are being utilized in the construction industry. Particularly, there is high interest in robots that can be applied to plastering automation, which can ensure consistent work quality. In this paper, we propose a robot platform based on wheels for plastering automation. Through experiments, we measured the surface pressure according to the air pressure of the wheel using the designed robot. As a result, we were able to confirm that the designed robot could perform plastering work on soft mortar with uniformly low pressure per wheel.

An Inter-floor Noise Prevention System using an Open-source Controller (오픈소스 컨트롤러를 사용한 층간 소음 방지 시스템)

  • Kim, Tae-Hoon;Jang, Hyuk-Jae;Lee, Won-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.5
    • /
    • pp.899-906
    • /
    • 2017
  • This paper proposes an inter-floor noise prevention system using an open-source controller. In the proposed system, Arduino which is a widely used open source controller analyzes sound signals and vibration signals with fast fourier transform. When the magnitude of the band-passed signal excesses the noise reference considering transmission loss of a panel or a wall, the system displays warning messages on an LCD module and a mobile device for users to be aware of the noise condition. In the experiment, the system has succeeded extracting and processing the band-passed signals between 130 Hz ~ 1040 Hz. When the magnitude of the extracted signal that is subtracted from the transmission loss exceeds 45 dB, the system has displayed the warning message on an LCD module and a mobile devicefor noise reduction.

The Effects of Housing Design on the Feeding Behaviors of Group Housed Pregnant Sow with Electronic Sow Feeder (돈방의 구조가 자동급이기를 활용한 임신돈의 섭식행동에 미치는 영향)

  • Song, Jun-Ik;Kim, Ji-Hyang;Jeon, Jung-Hwan;Lee, Jun-Yeob
    • Journal of Animal Environmental Science
    • /
    • v.20 no.4
    • /
    • pp.167-172
    • /
    • 2014
  • This study was conducted to evaluate the housing design on the feeding behaviors of group housed pregnant sows. A total of 65 sows (Landrace ${\times}$ Yorkshire) were employed into 2 experimental sow housing with different housing design. Lying area of one of sow housing was designed with concrete fence to give the shelter for weak sows. The other was floor type without any obstacles. Group housed sows were fed using electronic sow feeder (ESF) during gestation. Daily feeding pattern of sows was automatically recorded in ESF feeder program. Most sows ate all feed during night. Daily visiting frequency to ESF of sows in pig pen with the shelter was significantly lowered than sows in floor type pen. This study showed that the housing design of group housed sow pen could fairly impact ESF utilization of sow.