• Title/Summary/Keyword: electrodialyzer

Search Result 5, Processing Time 0.019 seconds

A computer simulation of ion exchange membrane electrodialysis for concentration of seawater

  • Tanaka, Yoshinobu
    • Membrane and Water Treatment
    • /
    • v.1 no.1
    • /
    • pp.13-37
    • /
    • 2010
  • The performance of an electrodialyzer for concentrating seawater is predicted by means of a computer simulation, which includes the following five steps; Step 1 mass transport; Step 2 current density distribution; Step 3 cell voltage; Step 4 NaCl concentration in a concentrated solution and energy consumption; Step 5 limiting current density. The program is developed on the basis of the following assumption; (1) Solution leakage and electric current leakage in an electrodialyzer are negligible. (2) Direct current electric resistance of a membrane includes the electric resistance of a boundary layer formed on the desalting surface of the membrane due to concentration polarization. (3) Frequency distribution of solution velocity ratio in desalting cells is equated by the normal distribution. (4) Current density i at x distant from the inlets of desalting cells is approximated by the quadratic equation. (5) Voltage difference between the electrodes at the entrance of desalting cells is equal to the value at the exits. (6) Limiting current density of an electrodialyzer is defined as average current density applied to an electrodialyzer when current density reaches the limit of an ion exchange membrane at the outlet of a desalting cell in which linear velocity and electrolyte concentration are the least. (7) Concentrated solutions are extracted from concentrating cells to the outside of the process. The validity of the computer simulation model is demonstrated by comparing the computed results with the performance of electrodialyzers operating in salt-manufacturing plants. The model makes it possible to discuss optimum specifications and operating conditions of a practical-scale electrodialyzer.

Chemical Changes During Desalting of Fish Sauces Using Electrodialyzer (전기투석기를 이용한 액젓의 탈염중 화학적 변화)

  • Oh, Se-Wook;Nam, Eun-Jung;Jo, Jin-Ho;Kim, Eun-Mi;Kim, Young-Myoung
    • Korean Journal of Food Science and Technology
    • /
    • v.29 no.5
    • /
    • pp.992-998
    • /
    • 1997
  • For the development of kimchi seasoning, fish sauces were desalted using electrodialyzer and some chemical components were analyzed. The salt content of fish sauce was adjusted to 20%, 15%, 10%, 5%, 2% and pH, total nitrogen (TN) content, amino nitrogen (AN) content and $NH_3$ content was determined. During desalting process pH was increased and TN, AN content also increased. But $NH_3$ content was decreased. It was surposed that $NH_3$ was eliminated with $Na^+$ because similar charge characteristic. In conclusion, using electrodialyzer fish sauce could be desalted to less than 2% and salt and moisture was co-eliminated.

  • PDF

Characterization of Desalination on the Boiled Extract of Baby Neck Clam(Tapes variegata) by Electrodialysis (전기투석기를 이용한 바지락 자숙액의 탈염 특성)

  • 박표잠;이상훈;김세권
    • Membrane Journal
    • /
    • v.10 no.2
    • /
    • pp.92-101
    • /
    • 2000
  • For selective elimination of salt in the boiled extract of baby neck clam (Tapes variegata, BEBNC), electrodialyzer was used and the desalination conditions of BEBNC were determined at various concentrations, pH's and volumes of BEBNC. The ion-exchange membrane with a molecular weight cut off 100 Da was used for desalting of BEBNC. The desalination times on BEBNC concentrations of 0.5% and 4% were 100 min and 170 min and the final desalting ratio was above 90%. 1'he desalination of BEBNC at pH 4.0 was 12% higher than that at pH 9.0 for 60 min. The electrodialysis process could remove above 90% of the initial salt content in 2% BEBNC of 1 L for 80 min. The results obtained prove that electrodialysis is a practical solution to the problem of selective elimination of salt from BEBNC.

  • PDF

Desalination of Traditional Soy Sauce Using Electrodialysis (전기투석에 의한 재래식 간장의 저염화)

  • Chung, Jae-Ho;Mok, Chul-Kyoon;Lim, Sang-Bin;Woo, Gun-Jo;Baek, Hyung-Hee;Park, Young-Seo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.811-817
    • /
    • 2002
  • Korean traditional soy sauce was desalted using electrodialyzer, and their physicochemical properties were analyzed. The salt content of soy sauce significantly decreased from initial 18.9 (w/v) to 0.47% (w/v) and the volume also decreased to 330 mL when 1,000 mL of soy sauce was desalted for 450 min at a current of 2 A. During the desalting process, the numbers of viable cells of total bacteria, yeasts, and molds increased due to the concentration effect of the electrodialysis. Turbidity increased from 3.1 to 8.5, and total nitrogen, total sugar, and reducing sugar contents also increased. The pH, and amino nitrogen and volatile base nitrogen contents slightly decreased, with ammonia content significantly decreasing from 19.4 to $1.3\;{\mu}mol/mL$. Free amino acids content increased twofold after electrodialysis. Gas chromatograms of soy sauce showed that profiles of the flavoring compounds did not change when electrodialyzed for 360 min, but most were removed after 540 min.

Desalination of Boiled Oyster Extract by Electrodialysis (전기투석에 의한 굴자숙액의 탈염 특성)

  • 박표잠;이상훈;김세권
    • KSBB Journal
    • /
    • v.15 no.2
    • /
    • pp.167-173
    • /
    • 2000
  • For selective elimination of salt from boiled oyster extract (BOE), electrodialyzer was used and the desalination conditions of B BOE were investigated. The ion-exchange membrane with a molecular weight cut off 100 Da was used for desalting of B BOE. The desalination efficiency at pH 4.0 was 13% higher than that at pH 9.0 when BOE was desalted for 90min. The e electrodialysis pro$\infty$ss could remove above 90% of the initial salt content when 5% BOE was desalted at pH 5.62 for 1 100min. The initial volume and concentration of permeation solution did not have significant effects on desalination time and r ratio. The important factors for the desalination of BOE were found to be pH and concentration of BOE. The results obtained prove that electrodialysis is a practical solution to the problem of selective elimination of salt from BOE.

  • PDF