• 제목/요약/키워드: electrode impedance

검색결과 687건 처리시간 0.03초

다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사 (Probing of Steel Bar Location inside Concrete using Multi-electrode Array)

  • 이형우;임홍철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF

A.C. 임피던스 측정에 의한 아연의 전착기구에 관한 고찰 (Studies on Electrodeposition Mechanism of Zinc By A.C. Impedance Measurement)

  • 안덕수;예길촌
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2007년도 추계학술대회 논문집
    • /
    • pp.26-26
    • /
    • 2007
  • To attest zinc electrodeposition mechanism, electric circuit models for zinc electro reaction on Pt electrode are analyzed from the a.c. impedance data. Electrochemical reactions of zinc deposition are composed of the three electrochemical reactions on the cathode layer and of the induced electrode layers.

  • PDF

바이오센서를 위한 PC 기반의 휴대용 고속 임피던스 분석기 개발 (Development of PC-based and portable high speed impedance analyzer for biosensor)

  • 김기련;김광년;허승덕;이승훈;최병철;김철한;전계록;정동근
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.33-41
    • /
    • 2005
  • For more convenient electrode-electrolyte interface impedance analysis in biosensor, a stand-alone impedance measurement system is required. In our study, we developed a PC-based portable system to analyze impedance of the electrochemical cell using microprocessor. The devised system consists of signal generator, programmable amplifiers, A/D converter, low pass filter, potentiostat, I/V converter, microprocessor, and PC interface. As a microprocessor, PIC16F877 which has the processing speed of 5 MIPS was used. For data acquisition, the sampling rate at 40 k samples/sec, resolution of 12 bit is used. RS-232 with 115.2 kbps speed is used for the PC communication. The square wave was used as stimuli signal for impedance analysis and voltage-controlled current measurement method of three-electrode-method were adopted. Acquired voltage and current data are calculated to multifrequency impedance signal after Fourier transform. To evaluate the implemented system, we set up the dummy cell as equivalent circuit of which was composed of resistor, parallel circuit of capacitor and resistor connected in parallel and measured the impedance of the dummy cell; the result showed that there exist accuracy within 5 % errors and reproduction within 1 % errors compared to output of Hioki LCR tester and HP impedance analyzer as a standard product. These results imply that it is possible to analyze electrode-electrolyte interface impedance quantitatively in biosensor and to implement the more portable high speed impedance analysis system compared to existing systems.

말초 신경 신호 기록의 효율성 개선을 위한 전도성 폴리머가 적용된 생체삽입형 커프형 신경전극 (Implantable Nerve Cuff Electrode with Conductive Polymer for Improving Recording Signal Quality at Peripheral Nerve)

  • 박성진;이이재;윤광석;강지윤;이수현
    • 센서학회지
    • /
    • 제24권1호
    • /
    • pp.22-28
    • /
    • 2015
  • This study demonstrates a polyimide nerve cuff electrode with a conductive polymer for improving recording signal quality at peripheral nerve. The nerve cuff electrodes with platinum (Pt), iridium oxide (IrOx), and poly(3,4-ethylenedioxythiophene): p-toluene sulfonate (PEDOT:pTS) were fabricated and investigated their electrical characteristics for improving recorded nerve signal quality. The fabricated nerve cuff electrodes with Pt, IrOx, and PEDOT:pTS were characterized their impedance and CDC by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry. The impedance of PEDOT:pTS measured at 1 kHz was $257{\Omega}$, which was extremely lower than the value of the nerve cuff electrodes with IrOx ($15897{\Omega}$) and Pt ($952{\Omega}$), respectively. Furthermore, the charge delivery capacity (CDC) of the nerve cuff electrode with PEDOT:pTS was dramatically increased to 62 times than the nerve cuff electrode with IrOx. In ex-vivo test using extracted sciatic nerve of spaque-dawley rat (SD rat), the PEDOT:pTS group exhibited higher signal-to-interference ratio than IrOx group. These results indicated that the nerve cuff electrode with PEDOT:pTS is promising for effective implantable nerve signal recording.

포도당 산화효소를 고정화한 Polypyrrole 나노튜뷸 효소전극의 포도당 용액 및 당뇨병 혈청에 대한 감응특성 (A Sensing of Glucose Solution and Diabetic Serum using Polypyrrole Nanotubules Enzyme Electrode Immobilized Glucose Oxidase)

  • 김현철;구할본
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 센서 박막재료
    • /
    • pp.6-10
    • /
    • 2001
  • We synthesized polypyrrole (PPy) nanotubules by oxidative polymerization of the pyrrole monomer on the pore of a polycarbonate membrane. The electrochemical behavior was investigated using cyclic voltammetry and AC impedance. The redox potential was about -0.5 V vs. Ag/AgCl reference electrode, while the potential was about 0 V for electro-synthesized PPy film. It is considered as the backbone grows according to the pore wall. Therefore, it is possible to be arranged regularly. That leads to improvement in the electron hopping. The AC impedance plot gave a hint of betterment of mass transport. PPy nanotubules have improved in mass transport, or diffusion. That is because the diffusion occurs through a thin pore wall of PPy nanotubules. The kinetic parameter of PPy nanotubules enzyme electrode with glucose solution was evaluated. The formal Michaelis constant and maximum current calculated by computer were about 23.8 mmol $dm^{-3}$ and $440\;{\mu}A$ respectively. Obviously, an affinity for the substrate and current response of the PPy nanotubules enzyme electrode are rather good, comparing with that of PPy film. What is more, the enzyme electrode is sensitive to blood sugar of a diabetic serum despite an obstruction of ascorbic acid, oxygen, some protein and/or hormone.

  • PDF

슈퍼커패시터용 그래핀볼 - 그래핀옥사이드 복합전극의 전기화학적 특성 (Electrochemical Property of the Composite Electrode with Graphene Balls and Graphene Oxide for Supercapacitor)

  • 정우준;오예찬;김상호
    • 한국표면공학회지
    • /
    • 제53권5호
    • /
    • pp.213-218
    • /
    • 2020
  • Composite material of the graphene ball (GB) inserted graphene oxide (GO) sheet for a supercapacitor electrode was studied. Chemical vapor deposition (CVD) process used to make GBs on the silicon oxide nanoparticles. The GBs mixed into the GO sheets to make GOGB and reduced it to create a reduced GOGB(RGOGB) composite. The RGOGB composite electrode had a large surface area and improved electrochemical properties. Specific capacitance of the RGBGO composite electrode was higher over 20 times than a pure GO and GOGB electrode in cyclic voltammetry(CV) tests, and the Z' and Z" impedance measured by an electrochemical impedance spectrometry(EIS) also low. So, the RGBGO composite electrode would use effectively to expand a performance of supercapacitor.

마멸 전극 기법과 교류 임피던스법으로 연구한 스테인리스강의 합금원소(Cr, Mo, N)가 재부동태 특성에 미치는 영향 (Effects of Alloying Elements(Cr, Mo, N) on Repassivation Characteristics of Stainless Steels Studied by the Abrading Electrode Technique and A.C Impedance Spectroscopy)

  • 함동호;김석원;이재봉
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.211-218
    • /
    • 2000
  • 마멸전극기법과 교류 임피던스법으로 스테인리스강의 합금원소, Cr, Mo, N가 합금의 재부동태 특성에 미치는 영향을 조사하였다. Fe-Cr, Fe-Cr-Mo, 304, 304LN, 316, 316LN등의 스테인리스강을 시편으로 사용하였으며 각 합금의 부동태 피막의 전기화학적 특성은 in-situ시험 기법인 d.c와 a.c전기화학적 기법을 각각 이용하였다 스테인리스강이 국부부식에 대하여 강한 저항성을 가지려면 부식 환경에서도 치밀한 부동태 피막을 유지해야 하고 피막의 파괴가 발생하더라도 재부동태 속도가 빨라야 하기 때문에 합금원소가 시간에 따른 재부동태 전류밀도와 재부동태 속도에 미치는 영향을 마멸 전극 시험법과 교류 임피던스 시험법으로 알아보았다. 부동태 피막의 안정성, 재부동태 속도 그리고 합금원소 사이의 관계를 규명하기 위하여 실험결과를 분석하였다.

최대 전압 12 kV, 커패시턴스 50~500 pF 가변 진공커패시터 개발 (Development of Variable Vacuum Capacitor with Maximum Voltage of 12 kV and Capacitance of 50 to 500 pF)

  • 차영광;이일회;전기범;장지훈;주흥진;최승길
    • 한국전기전자재료학회논문지
    • /
    • 제35권3호
    • /
    • pp.232-240
    • /
    • 2022
  • A variable vacuum capacitor (VVC), which is a variable element, is used to match impedance in plasma that changes with various impedance values, and its use is expanding with the rapid growth of the semiconductor business. Since VVCs have to secure insulation performance and vary capacitance within a compact size, electrode design and manufacturing are very important; thus, various technologies such as part design and manufacturing technology and vacuum brazing technology are required. In this study, based on the model of an advanced foreign company that is widely used for impedance matching in the manufacture of semiconductors and displays, a VVC that can realize the same performance was developed. The electrode part was designed, the consistency was confirmed through analysis, and the precision of capacitance was improved by designing a cup-type electrode to secure the concentricity of the electrode. As a result of the evaluation, all requirements was satisfied. We believe that self-development will be possible if satisfactory responses are received through evaluation by VVC consumers in the future.

가변주파수 인버터를 이용한 접지임피던스 측정 (Measurement of Impedance of the Grounding Grid using Variable Frequency Inverter)

  • 이복희;엄주홍;김교운
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.303-306
    • /
    • 2002
  • This paper presents a novel method for measuring the ground impedance in grounding systems. A square wave current was injected to the main grounding grid through auxiliary electrode, and the test current and ground potential rise(GPR) were measured using the band-pass filter. Ground impedance was calculated from the sinusoidal waveforms of the test current and GPR in frequency range of 20~2100Hz. Also the resistance and reactance component of ground impedance were analyzed.

  • PDF

임피던스를 이용한 흑연재료의 전극특성에 관한 연구 (A study on the characterization of electrode at graphite materials by impedance spectroscopy)

  • 오한준;김인기;이종호;이영훈
    • 한국결정성장학회지
    • /
    • 제6권4호
    • /
    • pp.571-583
    • /
    • 1996
  • 1 mM의 $[Fe(CN)_{6}]^{3-}/[Fe(CN)_{6}]^{4-}$ 이온이 첨가된 0.5 M $K_{2}SO_{4}$용액에서 Impedance spectroscopy를 통하여 비교적 porous한 표면조직을 갖는 흑연재료인 electrographite와 graphite foil의 계면의 전기화학적 거동을 조사하였다. 이들 두 흑연재료의 변전위 전류 전압곡선의 경우 전극표면의 구조로 인하여 비교적 높은 전류가 나타났으며, graphite foil의 경우 높은 이중층 용량이 나타났다. 또한 두 재료 모두 field transport의 작용에 의해 분극증가에 따른 임피던스 스펙트럼의 변화와 Faraday-임피던스의 변화가 크게 나타나지 않았다. 특히 electrographite의 경우 전극계면에서 흡착현상이 나타났으며, 양극분극의 증가에 의해 흡착현상은 현저하게 증가하였다.

  • PDF