• Title/Summary/Keyword: electrochemical sensor

Search Result 361, Processing Time 0.029 seconds

Development of HRP-modified Carbon Composite Biosensor and Electrochemical Analysis of H2O2 (Horseradish peroxidase가 변성된 탄소복합 바이오센서 개발 및 전기화학적 H2O2분석)

  • Park, Deog-Su
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.5
    • /
    • pp.571-576
    • /
    • 2012
  • A sol-gel derived carbon composite electrodes (CCEs) were fabricated by mixing horseradish peroxidase (HRP), sol of tetraethoxysilane (TESO), and graphite powder. The HRP solution was added to the sol solution of TEOS, and then graphite powder was added to this mixture. The resulting carbon ceramic network effectively encapsulated HRP and shows a catalytic reduction starting at -0.2 V for $H_2O_2$. The optimum conditions for $H_2O_2$determination have been characterized with respect to the enzyme loading ratio and pH. The linear range and detection limit of $H_2O_2$ detection were from 0.2 mM to 2.2 mM and 0.035 mM, respectively. The common electroactive interferences such as ascorbic acid, acetaminophene, and uric acid were not affected upon the response to $H_2O_2$ at the HRP biosensor due to low detection potential.

In situ analysis of the dynamic characteristics of electro-chemically Polymerized Polypyrrole film using Quartz Crystal Analyzer (Q.C.A.). (Q.C.A. 에 의한 폴리피롤 전기중합막의 동특성 분석)

  • Chang, Sang-Mok;Kim, Jong-Min;Chang, Yong-Keun;Muramatsu, Hiroshi;Ataka, Tatsuaki
    • Journal of Sensor Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.71-79
    • /
    • 1996
  • The mechanism of electrochemical polymerization of polypyrrole was analyzed using Q.C.A. via measuring the resonant frequency and resonant resistance of AT-cut quartz crystal, whose electrodes were fabricated with indium tin oxide by sputtering method. The quantity of polymerized polypyrrole was able to be calculated from the resonant frequency and the viscoelasticity of polypyrrole film from resonant resistance. We found that the elastic film is formed at the first stage of the polymerization, but transformed to viscoelastic film later and that this transition repeated at some point. From these results, it was confirmed that the rheological characteristics of electrochemically polymerized polypyrrole thin film can be analyzed using Q.C.A.

  • PDF

Fabrication and Electrochemical Analysis of Back-gate FET Based on Graphene for O2 Gas Sensor

  • Kim, Jin-Hwan;Choe, Hyeon-Gwang;Kim, Jong-Yeol;Im, Gi-Hong;Jeon, Min-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.271-271
    • /
    • 2014
  • 본 연구에서는 최근 다양한 전자 소자로써의 연구가 진행되고 있는 그라핀을 SiO2/Si 기판 위에 전자빔 식각(Electron-Beam Lithography)을 이용하여 후면 게이트 전극 구조의 그라핀 채널을 갖는 삼단자 소자를 형성하고 가스 유입이 가능한 진공 Probe Measurement System을 이용하여 금속 전극과 그라핀 간의 접촉저항 (Rc) 및 길이가 다른 채널저항(Rch)를 구하고, 채널 길이, 가스 유량, 온도, 게이트 전압에 따른 I-V 변화를 측정함으로써, 후면 게이트 전극 구조의 그라핀 채널을 갖는 삼단자 소자의 가스 센서로서의 가능성을 연구하였다. 후면 게이트 전극 구조의 그라핀 채널을 갖는 삼단자 소자는 전자빔 식각(Electron-Beam Lithography)에 의해 패턴을 제작하고 Evaporator를 이용하여 전극을 증착 하였다. 소자의 소스 (Source)와 드레인 (Drain)은 TLM (Transfer Length Method)패턴을 이용하여 인접한 두 개의 전극간 범위를 변화시키는 형태로 제작함으로써 소스-드레인간 채널 길이가 다르게 하였다. 이 때 전극의 크기는 가로, 세로 각각 $20{\mu}m$, $40{\mu}m$이며 전극간 간격은 $20/30/40/50/60{\mu}m$로 서로 다르게 배열 하였다. 제작된 그라핀 소자는 진공 Probe Measurement System 내에서 게이트 전압(VG)를 변화시킴으로써 VG 변화에 따른 소자의 특성을 평가하였는데, mTorr 상태의 챔버 내로 O2 가스를 주입하여 그라핀의 Dangling bond 및 Defect site에 결합 된 가스로 인한 전기적 특성의 변화를 측정하고, 이 때 가스의 유량을 50 sccm에서 500 sccm 까지 변화시킴으로써 전기적 특성 변화를 측정하여 센서 소자의 민감도를 평가하였다. 또한, 서로 다르게 배열한 소스-드레인 간의 채널 길이로 인하여 채널과의 접촉 면적에 따른 센서 소자의 민감도 또한 평가할 수 있었다. 그리고 챔버 내 온도를 77 K에서 400 K까지 변화시킴으로써 온도에 따른 소자의 작동 범위를 확인하고 소자의 온도의존성을 평가하였다.

  • PDF

An Aptamer-Based Electrochemical Sensor That Can Distinguish Influenza Virus Subtype H1 from H5

  • Lee, Jin-Moo;Kim, JunWon;Ryu, Ilhwan;Woo, Hye-Min;Lee, Tae Gyun;Jung, Woong;Yim, Sanggyu;Jeong, Yong-Joo
    • Journal of Microbiology and Biotechnology
    • /
    • v.27 no.11
    • /
    • pp.2037-2043
    • /
    • 2017
  • The surface protein hemagglutinin (HA) mediates the attachment of influenza virus to host cells containing sialic acid and thus facilitates viral infection. Therefore, HA is considered as a good target for the development of diagnostic tools for influenza virus. Previously, we reported the isolation of single-stranded aptamers that can distinguish influenza subtype H1 from H5. In this study, we describe a method for the selective electrical detection of H1 using the isolated aptamer as a molecular probe. After immobilization of the aptamer on Si wafer, enzyme-linked immunosorbent assay (ELISA) and field emission scanning electron microscopy (FE-SEM) showed that the immobilized aptamer bound specifically to the H1 subtype but not to the H5 subtype. Assessment by cyclic voltammetry (CV) also demonstrated that the immobilized aptamer on the indium thin oxide-coated surface was specifically bound to the H1 subtype only, which was consistent with the ELISA and FE-SEM results. Further measurement of CV using various amounts of H1 subtype provided the detection limit of the immobilized aptamer, which showed that a nanomolar scale of target protein was sufficient to produce the signal. These results indicated that the selected aptamer can be an effective probe for distinguishing the subtypes of influenza viruses by monitoring current changes.

Implantable Nerve Cuff Electrode with Conductive Polymer for Improving Recording Signal Quality at Peripheral Nerve (말초 신경 신호 기록의 효율성 개선을 위한 전도성 폴리머가 적용된 생체삽입형 커프형 신경전극)

  • Park, Sung Jin;Lee, Yi Jae;Yun, Kwang-Seok;Kang, Ji Yoon;Lee, Soo Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.22-28
    • /
    • 2015
  • This study demonstrates a polyimide nerve cuff electrode with a conductive polymer for improving recording signal quality at peripheral nerve. The nerve cuff electrodes with platinum (Pt), iridium oxide (IrOx), and poly(3,4-ethylenedioxythiophene): p-toluene sulfonate (PEDOT:pTS) were fabricated and investigated their electrical characteristics for improving recorded nerve signal quality. The fabricated nerve cuff electrodes with Pt, IrOx, and PEDOT:pTS were characterized their impedance and CDC by using electrochemical impedance spectroscopy (EIS) and cyclic voltammetry. The impedance of PEDOT:pTS measured at 1 kHz was $257{\Omega}$, which was extremely lower than the value of the nerve cuff electrodes with IrOx ($15897{\Omega}$) and Pt ($952{\Omega}$), respectively. Furthermore, the charge delivery capacity (CDC) of the nerve cuff electrode with PEDOT:pTS was dramatically increased to 62 times than the nerve cuff electrode with IrOx. In ex-vivo test using extracted sciatic nerve of spaque-dawley rat (SD rat), the PEDOT:pTS group exhibited higher signal-to-interference ratio than IrOx group. These results indicated that the nerve cuff electrode with PEDOT:pTS is promising for effective implantable nerve signal recording.

A glucose biosensor based on deposition of glucose oxidase onto Au nanoparticles poly(maleic anhydride)-grafted multiwalled carbon nanotube electrode (금 나노입자/폴리(maleic anhydride) 그래프트 탄소나노튜브에 글루코스 옥시다아제 담지를 기반으로 한 글루코스 바이오센서)

  • Piao, Ming-Hua;Son, Pyeong-Soo;Chang, Choo-Hwan;Choi, Seong-Ho
    • Analytical Science and Technology
    • /
    • v.23 no.2
    • /
    • pp.165-171
    • /
    • 2010
  • Glucose oxidase ($GOD_{ox}$) immobilized biosensor was fabricated by two methods. In one of the methods, gold nanoparticles (Au-NPs) prepared by ${\gamma}$-irradiation were loaded into the poly(maleic anhydride)-grafted multi-walled carbon nanotube, PMAn-g-MWCNT electrode via physical entrapment. In the other method, the Au-NPs were prepared by electrochemical reduction of Au ions on the surface of PMAn-g-MWCNT electrode and then GODox was immobilized into the Au-NPs. The $GOD_{ox}$ immobilized biosensors were tested for electrocatalytic activities to sense glucose. The sensing range of the biosensor based on the Au-NPs physically modified PMAn-g-MWCNT electrode was from $30\;{\mu}M$ to $100\;{\mu}M$ for the glucose concentration, and the detection limit was $15\;{\mu}M$. Interferences of ascorbic acid and uric acid were below 7.6%. The physically Au deposited PMAn-g-MWCNT paste electrodes appear to be good sensor in detecting glucose.

Analysis Methods for Measurement of Ammonia Concentration (가스상 암모니아 측정을 위한 분석방법별 특성 연구)

  • Sa, Jae-Hwan;Yoon, Seok-Kyung;Roh, Gi-Hwan;Jeon, Eui-Chan
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.43-54
    • /
    • 2008
  • Management and control of ammonia at the sources and ambient largely depend on sampling and measurement techniques. Good sampling and measurement techniques provide high quality data. The main purpose of the study is compare the analytical characteristics of the Indolphenol method which is one of the standard method in Korea with automatic analyzers for continued measuring gaseous ammonia. For comparison with other analytical methods, the verification test was designed to evaluate performance parameters; linearity, absorption efficiency, reproducibility and repeatability test, accuracy, and response time test. $R^2$ of calibration curve using IPM and CLM was very high (value is 1.000), but for EcSM $R^2$ value was estimated to be lower than IPM and CLM (as 0.991). The RSD of the CLM ranged from 0.1 to 2.3% over the nine concentration levels measured, %Ds was 0.1 to 10.7%, and average RA over all the measurements was 3.3%. The RSD of IPM and EcSM was ranged from 1.0 to 8.1, 3.9 to 14.0 respectively, and average RA were 8.71, 4.9% respectively. Rise in response times of EcSM was estimated to be 1 minute. It is found to be more sensitive than response time (which ranged from 2 to 9 minute) of CLM. For ammonia concentration measured using the IPM and the CLM from the same ammonia source, linear regression of IPM versus CLM show a slope of 0.805, an intercept of 637 ppb, and $R^2$ of 0.868.

Highly sensitive and selective enzymatic detection for hydrogen peroxide using a non-destructively assembled single-walled carbon nanotube film (탄소나노튜브 대면적 어셈블리를 통한 고감도-고선택성 과산화수소 센서 개발)

  • Lee, Dongwook;Ahn, Heeho;Seo, Byeong-Gwuan;Lee, Seung-Woo
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.229-235
    • /
    • 2021
  • This study presents a simple approach for the assembly of a free-standing conductive electronic nanofilm of single-walled carbon nanotubes (SWNTs) suitable for enzymatic electrochemical biosensors. A large-scale SWNT electronic film was successfully produced by the dialysis of p-Terphenyl-4,4''-dithiol (TPDT)-treated SWNTs. Furthermore, Horseradish peroxidase (HRP) was immobilized on the TPDT-SWNT electronic film, and the enzymatic detection of hydrogen peroxide (H2O2) was demonstrated without mediators. The detection of H2O2 in the negative potential range (-0.4 V vs. Ag/AgCl) was achieved by direct electron transfer of heme-based enzymes that were immobilized on the TPDT-SWNT electronic film. The SWNT-based biosensor exhibited a wide detection range of H2O2 from 10 µM to 10 mM. The HRP-doped SWNT electronic film achieved a high sensitivity of 342 ㎛A/mM·cm2 and excellent selectivity against a variety of redox-active interfering substances, such as ascorbic acid, uric acid, and acetaminophen.

Self-diagnosis Algorithm for Water Quality Sensors Based on Water Quality Monitoring Data (수질 모니터링 데이터 기반의 수질센서 자가진단 알고리즘)

  • HongJoong Kim;Jong-Min Kim;Tae-Hyung Kang;Gab-Sang Ryu
    • Journal of Internet of Things and Convergence
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2023
  • Today, due to the increase in global population growth, the international community is discussing solving the food problem. The aquaculture industry is emerging as an alternative to solving the food problem. For the innovative growth of the aquaculture industry, smart fish farms that combine the fourth industrial technology are recently being distributed, and full-cycle digitalization is being promoted. Water quality sensors, which are important in the aquaculture industry, are electrochemical portable sensors that check water quality individually and intermittently, making it impossible to analyze and manage water quality in real time. Recently, optically-based monitoring sensors have been developed and applied, but the reliability of monitoring data cannot be guaranteed because the state information of the water quality sensor is unknown. Therefore, this paper proposes an algorithm representing self-diagnosis status such as Failure, Out of Specification, Maintenance Required, and Check Function based on monitoring data collected by water quality sensors to ensure data reliability.

Effects of Chloride and Sulfate Ions on Corrosion Behaviors of Structural Materials Based on Design of Experiment (실험계획에 기반한 수돗물 성분(Chloride and Sulfate Ions)의 구조재료 부식 영향성 고찰)

  • Dong-In Lim;Heng-Su Noh;Hyeok-Jun Kwon;Sung-Ryul Park;Man-Sik Jo;Doo-Youl Lee
    • Corrosion Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.201-213
    • /
    • 2023
  • Corrosion management of an aircraft and its engine relies on rinsing and cleaning using tap water. Few studies have reported effects of tap water species on corrosion behaviors of structural materials. In this study, a series of experiments were conducted based on the design of experiment. Solutions with different levels of chloride and sulfate ions were prepared using a full factorial design. Two structural materials (aluminum alloy and steel) were used for an alternate immersion test. Weight loss was then measured. In addition, a silver specimen was utilized as a sensor for chloride deposition measurement. The silver specimen was examined using the electrochemical reduction method, XPS, and SEM-EDS. Surface analysis revealed that levels of chloride and sulfate ions were sufficient for the formation of silver chloride and silver surface. Statistical analysis of weight loss and chloride deposition rate showed significant differences in measured values. Concentration of chloride ions greatly affected corrosion behaviors of structural materials. Sulfate ion hindered the adsorption reaction. These results emphasize the importance of controlling ion concentration of tap water used for cleaning and rinsing an aircraft.