• Title/Summary/Keyword: electrochemical measurements

Search Result 402, Processing Time 0.024 seconds

A Hybrid Electrochemical Capacitor Using Aqueous Electrolyte (수용성 전해액을 사용하는 하이브리드 전기화학 축전기)

  • Kim, Jong-Huy;Jin, Chang-Soo;Shin, Kyoung-Hee;Lee, Mi-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.6 no.2
    • /
    • pp.153-157
    • /
    • 2003
  • A hybrid electrochemical capacitor having both characteristics of electric double layer capacitance and pseudo-capacitance was studied throughout cell tests. Asymmetric electrodes with $Ni(OH)_2/activated$ carbon based positive electrode and activated carbon based negative electrode were used in preparing test cells of $5\times5cm^2$. Cyclic voltammetry measurements and impedance measurements were conducted to understand electrochemical behavior of each electrode. To find an optimal mass ratio of negative to positive electrode, charge-discharge cycle tests were also performed.

Stability and Electrochemical Characteristics of Polyaniline Salt Films in 1 N HCl Solution

  • 조정환;오응주;요철현
    • Bulletin of the Korean Chemical Society
    • /
    • v.17 no.8
    • /
    • pp.715-719
    • /
    • 1996
  • Thin films of polyaniline (PANI) salts were in situ deposited on a Pt plate during either chemical polymerization or electrochemical polymerization. The oxidation states of the salt films were controlled by the applied DC potential. AC impedance of the Pt/PANI electrode were measured in monomer-free 1 N HCl solution in order to investigate the electrodic properties of the films at the following applied DC potentials: 0, 0.45 and 0.75 V vs. SCE. Very small differences in film conductivity according to its oxidation state were observed by analysis of the impedance spectra, the reasons of which are complicated by enriched water content in the film and possible decrease in the film thickness during the measurements. The electrochemical activity of the film/solution interface varied with its oxidation state. Stability of the film in 1 N HCl solution was also evaluated by impedance and cyclic voltammetry measurements.

Lithium Ion Concentration Dependant Ionic Conductivity and Thermal Properties in Solid Poly(PEGMA-co-acrylonitrile) Electrolytes

  • Kim, Kyung-Chan;Roh, Sae-Weon;Ryu, Sang-Woog
    • Journal of Electrochemical Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.57-62
    • /
    • 2010
  • The lithium ion concentration dependant ionic conductivity and thermal properties of poly(ethylene glycol) methyl ether methacrylate (PEGMA)/acrylonitrile-based copolymer electrolytes with $LiClO_4$ have been studied by differential scanning calorimetry (DSC), linear sweep voltammetry (LSV) and AC complex impedance measurements. In systems with 11 wt% of acrylonitrile all liquid electrolytes were obtained regardless of lithium ion concentration. Complex impedance measurements with stainless steel electrodes give ambient ionic conductivities $8.1\times10^{-6}\sim1.4\times10^{-4}S cm^{-1}$. On the other hand, a hard and soft films at ambient temperature were obtained in copolymer electrolyte system consists of 15 wt% acrylonitrile with 6 : 1 and 3 : 1 of [EO] : [Li] ratio, respectively. DSC measurements indicate the crystalline melting temperature of poly(PEGMA) disappeared completely after addition of $LiClO_4$ in this system due to the complex formation between ethylene oxide (EO) unit and lithium salt. As a result, free standing film with room temperature ionic conductivity of $1.7\times10^{-4}S cm^{-1}$ and high electrochemical stability up to 5.5V was obtained by controlling of acrylonitrile and lithium salt concentration.

Electrical Impedance Spectroscopy(EIS) Measurements to Evaluate Corrosion of Steel/Concrete System (교류 임피던스기법을 이용한 철근부식 측정에 관한 실험적 연구)

  • Jung, Si-Young;Kim, Byoung-Kook;Choi, Oan-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.659-662
    • /
    • 2005
  • Electrochemical impedance spectroscopy (EIS) has been extensively used to try to evaluate the corrosion state of the steel/concrete system. This technique is attractive because, in theory, used in a wide range of frequencies, it can give detailed information about the mechanisms and kinetics of the electrochemical reactions. Impedance measurements were performed using potential control and measuring the corresponding current response. One-year-old southern exposure test. specimens were used in the current study. The effectiveness of corrosion inhibiting additives was evaluated. The corrosion current densities estimated by impedance measurements were confirmed by those determined using linear polarization techniques. The purpose of this study was to evaluate the long-term-performance potential of the corrosion inhibitors in chloride contaminated reinforce concrete.

  • PDF

Resolution of a Multi-Step Electron Transfer Reaction by Time Resolved Impedance Measurements: Sulfur Reduction in Nonaqueous Media

  • Park, Jin-Bum;Chang, Byoung-Yong;Yoo, Jung-Suk;Hong, Sung-Young;Park, Su-Moon
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.9
    • /
    • pp.1523-1530
    • /
    • 2007
  • The first reduction peak of the cyclic voltammogram (CV) for sulfur reduction in dimethyl sulfoxide has been studied using time resolved Fourier transform electrochemical impedance spectroscopic (FTEIS) analysis of small potential step chronoamperometric currents. The FTEIS analysis results reveal that the impedance signals obtained during short potential steps can be resolved into electron transfer reactions of two different time constants in a high frequency region. The FTEIS method provides snap shots of impedance profiles during an earlier phase of the reaction, leading to time resolved EIS measurements. Our results obtained by the FTEIS analysis are consistent with a series of electron transfer and chemical equilibrium steps of a complex reaction, making up an ECE (electrochemical-chemical-electrochemical) mechanism postulated from the results of computer simulation.

Electrochemical Determination of Glucose Concentration Contained in Salt Solution (소금용액에 포함된 글루코오스 농도의 전기화학적 측정)

  • 김영한
    • Journal of Korean Port Research
    • /
    • v.14 no.4
    • /
    • pp.475-479
    • /
    • 2000
  • A possibility of the implementation of a quartz crystal sensor to the determination of chemical oxygen demand is examined by checking the electrochemical behavior of the sensor in a glucose solution. Since the surface of a quartz crystal has to be oxidized, a relatively active metal is coated on the surface of a usual 9 MHz AT-cut crystal. The electrochemical behavior is investigated by measuring the changes of current, resonant frequency and resonant resistance while a constant potential is applied. The crystal is installed in a specially designed container, and a quartz crystal analyzer is utilized to measure the frequency and resistance simultaneously. The variations of the measurements are examined at different concentrations of glucose solution, and a proper relation between the concentrations of glucose solution, and a proper relation between the concentration and the measurements is analyzed. As a result, it is found that a linear relation between the concentration of less than 900 ppm and the peak current when a constant potential of -180 mV (SSCE) is applied. The relation can be utilized for the determination of glucose concentration in sea water, and considering a direct relation between gluose concentration and chemical oxygen demand tells a possibility of the measurement of chemical oxygen demand using quartz crystal oscillators.

  • PDF

Evaluation of the Inhibitive Performance of Cyperus Conglomeratus Leaves Extract as a Green Corrosion Inhibitor on Mild Steel XC70 in Acid Medium

  • Belkis, Guessoum;Abdelkader, Hadj Seyd;Oumelkheir, Rahim
    • Corrosion Science and Technology
    • /
    • v.21 no.3
    • /
    • pp.171-183
    • /
    • 2022
  • The performance and inhibitory action of the aqueous extract of Cyperus Conglomeratus's leaves against corrosion of XC70 steel in a 1M HCl acid medium are studied by the determination of the weight loss, the potentiodynamic polarization curves analysis, and electrochemical impedance measurements (electrochemical techniques). The corrosion inhibitory efficiency of XC70 steel increases with the increasing concentration of the green inhibitor, however, the corrosion rate of the steel decreases. Weight loss measurements show that the maximum percentage corrosion inhibition efficiency is approximately 61.86%, while the analysis of the mixed character polarization curves shows that the inhibitor could achieve an inhibition efficiency of 86.96%. The electrochemical impedance study confirmed that the value of the charge transfer resistance (Rct) increases and the value of the double layer capacity (Cdl) decreases with increasing concentration of the aqueous extract of Cyperus Conglomeratus's leaves, thus increasing the inhibition efficiency. The study showed that this aqueous extract acts by adsorption on the metal surface; this adsorption follows the Langmuir isotherm. This research work showed that Cyperus Conglomeratus leaves extract acts as an effective and eco-friendly inhibitor on mild steel in an acid medium.

Singular Point of Voltammetric Impedance Data and its Application in Analyzing Voltammetry Data

  • Chang, Byoung-Yong
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.149-156
    • /
    • 2018
  • In this technical note, I report the analysis of electrochemical impedance data measured with potential sweeping. Even though the instruments for voltammetric impedance measurements have been developed for decades using different approaches, their applications are limited due to the lack of well-established protocols to easily analyze voltammetry data. To fill this gap, the singular point of the specific potential is considered that is only determined by the standard/formal potential and the transfer coefficient and is independent of the kinetics and experimental parameters (including revertability) of faradaic reactions. Taking the advantage of its inertness, I suggest an approach employing the singular point as a reference to obtain general electrochemical information. As all the concepts and methods are verified with numerical simulations, this technique is expected to be applied for complex reactions involving electrochemical and chemical reaction mechanisms.

Electrodeposition of GMR Ni/Cu Multilayers in a Recirculating Electrochemical Flow Reactor

  • Rheem, Young-Woo
    • Korean Journal of Materials Research
    • /
    • v.20 no.2
    • /
    • pp.90-96
    • /
    • 2010
  • The recirculating electrochemical flow reactor developed at UCLA has been employed to fabricate nanostructured GMR multilayers. For comparison, Ni/Cu multilayers have been electrodeposited from a single bath, from dual baths and from the recirculating electrochemical flow reactor. For a magnetic field of 1.5 kOe, higher GMR (Max. -5%) Ni/Cu multilayers with low electrical resistivity (< $10\;{\mu}{\Omega}{\cdot}cm$) were achieved by the electrochemical flow reactor system than by the dual bath (Max. GMR = -4.2% and < $20\;{\mu}{\Omega}{\cdot}cm$) or the single bath (Max. GMR = -2.1% and < $90\;{\mu}{\Omega}{\cdot}cm$) techniques. Higher GMR effects have been obtained by producing smoother, contiguous layers at lower current densities and by the elimination of oxide film formation by conducting deposition under an inert gas environment. Our preliminary GMR measurements of Ni/Cu multilayers from the electrochemical flow reactor obtained at low magnetic field of 0.15 T, which may approach or exceed the highest reported results (-7% GMR) at magnetic fields > 5 kOe.

Electrochemical Biosensors for Biomedical and Clinical Applications: A Review

  • Rahman Md. Aminur;Park Deog-Su;Shim Yoon-Bo
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.271-282
    • /
    • 2005
  • There are strong demands for accurate, fast, and inexpensive devices in the medical diagnostic laboratories, such as biosensors and chemical sensors. Biosensors can provide the reliable and accurate informations on the desired biochemical parameters, which is an essential prerequisite for a patient before going for a treatment. They can be used for continuous measurements of metabolites, blood cations, gases, etc. Of these, electrochemical biosensors play an important role in the improvement of public health, because rapid detection, high sensitivity, small size, and specificity are achievable for clinical diagnostics. In this paper, the clinical applications with electrochemical biosensors are reviewed. An attempt is also made to highlight some of the trends that govern the research and developments of the important biosensors that are associated to clinical diagnosis.