• 제목/요약/키워드: electrocardiography (ECG)

검색결과 78건 처리시간 0.04초

MEMS 기술과 유연인쇄회로기판 기술을 이용한 단일지점 검침 심전도 센서 (One point detection electrocardiography sensor using MEMS and flexible printed circuit technology)

  • 김홍래;이충일;이충근;이명호;김현준;최의중;김용준
    • 센서학회지
    • /
    • 제18권5호
    • /
    • pp.359-364
    • /
    • 2009
  • This paper presents flexible electrocardiography(ECG) sensors using micro electro mechanical systems(MEMS) and flexible printed circuit(FPC) technology. By using FPC technology, ECG sensors which consisted of an outer hook-shaped electrode and an inner circular-shaped electrode were fabricated on the polyimide substrate. Thereafter, the bipolar ECG sensor was miniaturized using MEMS technology. The ECG measurement capability was examined by attaching the sensor to the human chest and wrist. Performance of the proposed sensors was then compared with ECG measured by commercial Ag/AgCl electrodes. It was verified that ECG could be measured using proposed sensors at only single body.

상호연동성을 지원하는 XML기반의 심전도 데이터 관리를 위한 메타데이터 시스템 (Metadata System for XML-based ECG Management Supporting Interoperability)

  • 구흥서
    • 한국지능시스템학회논문지
    • /
    • 제16권6호
    • /
    • pp.704-709
    • /
    • 2006
  • 본 연구에서는 의료정보시스템 간에 상호연동성을 지원한 수 있는 XML 기반의 심전도(electrocardiography, 이하 ECG) 데이터의 효율적인 저장구조 및 관리방법을 제시하고, 웹기반으로 ECG 정보서비스를 제공할 수 있는 ECG 메타데이터 시스템을 구현한다. ECG 메타데이터 시스템은 ECG 데이터와 메타데이터의 저장, 검색, 그리고 pdf 파일형식의 리포팅 서비스 기능을 포함한다. ECG 데이터의 저장구조는 심전도 데이터의 특성과 액세스 특성을 분석하여 비분할 저장방식을 사용하였고, 효율적인 검색기능을 제공하기 위해 HL7 aECG 데이터로부터 메타데이터를 추출하여 인덱스로 활용하였다. ECG 리포팅 서비스를 제공하기 위해 템플릿 메커니즘을 이용하여 텍스트 XML 형태의 데이터를 여러 데이터 포맷으로 변환한다.

지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발 (Zigbee based 1-ch ECG device with activity monitoring function)

  • 홍주현;김남진;차은종;이태수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF

귀 주변에서 측정한 유사 심전도 기반 개인 인증 시스템 개발 가능성 (Feasibility of Using Similar Electrocardiography Measured around the Ears to Develop a Personal Authentication System)

  • 최가영;박종윤;김다영;김연우;임지헌;황한정
    • 대한의용생체공학회:의공학회지
    • /
    • 제41권1호
    • /
    • pp.42-47
    • /
    • 2020
  • A personal authentication system based on biosignals has received increasing attention due to its relatively high security as compared to traditional authentication systems based on a key and password. Electrocardiography (ECG) measured from the chest or wrist is one of the widely used biosignals to develop a personal authentication system. In this study, we investigated the feasibility of using similar ECG measured behind the ears to develop a personal authentication system. To this end, similar ECGs were measured from thirty subjects using a pair of three electrodes attached behind each of the ears during resting state during which the standard Lead-I ECG was also simultaneously measured from both wrists as baseline ECG. The three ECG components, Q, R, and S, were extracted for each subject as classification features, and authentication accuracy was estimated using support vector machine (SVM) based on a 5×5-fold cross-validation. The mean authentication accuracies of Lead I-ECG and similar ECG were 90.41 ± 8.26% and 81.15 ± 7.54%, respectively. Considering a chance level of 3.33% (=1/30), the mean authentication performance of similar ECG could demonstrate the feasibility of using similar ECG measured behind the ears on the development of a personal authentication system.

Wireless Three-Pad ECG System: Challenges, Design, and Evaluations

  • Cao, Huasong;Li, Haoming;Stocco, Leo;Leung, Victor C.M.
    • Journal of Communications and Networks
    • /
    • 제13권2호
    • /
    • pp.113-124
    • /
    • 2011
  • Electrocardiography (ECG) is a widely accepted approach for monitoring of cardiac activity and clinical diagnosis of heart diseases. Since cardiologists have been well-trained to accept 12-lead ECG information, a huge number of ECG systems are using such number of electrodes and placement configuration to facilitate fast interpretation. Our goal is to design a wireless ECG system which renders conventional 12-lead ECG information.We propose the three-pad ECG system (W3ECG). W3ECG furthers the pad design idea of the single-pad approach. Signals obtained from these three pads, plus their placement information, make it possible to synthesize conventional 12-lead ECG signals.We provide one example of pad placement and evaluate its performance by examining ECG data of four patients available from online database. Feasibility test of our selected pad placement positions show comparable results with respect to the EASI lead system. Experimental results also exhibit high correlations between synthesized and directly observed 12-lead signals (9 out of 12 cross-correlation coefficients higher than 0.75).

Image Quality and Radiation Dose of High-Pitch Dual-Source Spiral Cardiothoracic Computed Tomography in Young Children with Congenital Heart Disease: Comparison of Non-Electrocardiography Synchronization and Prospective Electrocardiography Triggering

  • Goo, Hyun Woo
    • Korean Journal of Radiology
    • /
    • 제19권6호
    • /
    • pp.1031-1041
    • /
    • 2018
  • Objective: To compare image quality and radiation dose of high-pitch dual-source spiral cardiothoracic computed tomography (CT) between non-electrocardiography (ECG)-synchronized and prospectively ECG-triggered data acquisitions in young children with congenital heart disease. Materials and Methods: Eighty-six children (${\leq}3$ years) with congenital heart disease who underwent high-pitch dual-source spiral cardiothoracic CT were included in this retrospective study. They were divided into two groups (n = 43 for each; group 1 with non-ECG-synchronization and group 2 with prospective ECG triggering). Patient-related parameters, radiation dose, and image quality were compared between the two groups. Results: There were no significant differences in patient-related parameters including age, cross-sectional area, body density, and water-equivalent area between the two groups (p > 0.05). Regarding radiation dose parameters, only volume CT dose index values were significantly different between group 1 ($1.13{\pm}0.09mGy$) and group 2 ($1.07{\pm}0.12mGy$, p < 0.02). Among image quality parameters, significantly higher image noise ($3.8{\pm}0.7$ Hounsfield units [HU] vs. $3.3{\pm}0.6HU$, p < 0.001), significantly lower signal-to-noise ratio ($105.0{\pm}28.9$ vs. $134.1{\pm}44.4$, p = 0.001) and contrast-to-noise ratio ($84.5{\pm}27.2$ vs. $110.1{\pm}43.2$, p = 0.002), and significantly less diaphragm motion artifacts ($3.8{\pm}0.5$ vs. $3.7{\pm}0.4$, p < 0.04) were found in group 1 compared with group 2. Image quality grades of cardiac structures, coronary arteries, ascending aorta, pulmonary trunk, lung markings, and chest wall showed no significant difference between groups (p > 0.05). Conclusion: In high-pitch dual-source spiral pediatric cardiothoracic CT, additional ECG triggering does not substantially reduce motion artifacts in young children with congenital heart disease.

The Characteristics of Electrocardiography Findings in Left Ventricular Remodeling Patterns of Hypertensive Patients

  • Choi, Sun Young
    • 대한의생명과학회지
    • /
    • 제21권4호
    • /
    • pp.208-217
    • /
    • 2015
  • The exact diagnosis of left ventricular hypertrophy (LVH) is very important in the treatment of hypertension. The purpose of our study is to determine the relationship between left ventricular remodeling patterns and electrocardiography (ECG) findings in hypertensive patients. We divided 137 patients into four groups according to left ventricular mass index (LVMI) and the relative wall thickness: normal, concentric remodeling, concentric hypertrophy, eccentric hypertrophy. LVH on the ECG was defined by three ECG criteria: Sokolow-Lyon voltage criteria, Cornell voltage criteria and Romhilt-Estes point score. LVH on the echocardiography was defined by LVMI. The prevalence of ECG LVH was increased in concentric hypertrophy and eccentric hypertrophy group. The QRS voltages by Sokolow-Lyon voltage criteria (r = 0.494, P = 0.002) and Cornell voltage criteria (r = 0.628, P < 0.001), and Romhilt-Estes point score (r = 0.689, P < 0.001) were positively correlated with LVMI. Also, the QRS voltages and point scores were significantly increased in the concentric hypertrophy and eccentric hypertrophy group with increased LVMI. The QRS voltage and Romhilt-Estes point scores were positively correlated with LVMI. The QRS voltages and Romhilt-Estes point scores were also increased in the left ventricular remodeling groups with increased LVMI.

심전도신호의 R-R 간격을 이용한 부정맥 구간 검출 알고리즘 (Detection Algorithm of Cardiac Arrhythmia in ECG Signal using R-R Interval)

  • 김경호;이상운;김진영
    • 한국위성정보통신학회논문지
    • /
    • 제9권1호
    • /
    • pp.85-89
    • /
    • 2014
  • 심전도(electrocardiography, ECG)는 심장박동을 할 때, 발생하는 탈분극과 재분극으로 심장의 전위변화를 시간의 흐름에 따라 파형으로 표현한 것이다. 의료기관에서는 심전도신호를 이용하여 환자의 심장질환을 진단한다. 일반적으로 사람의 정상적인 심장박동수는 1분에 60-100회 이다. 만약 정상적인 심장박동 수보다 느리거나 빠르다면 부정맥이라고 한다. 본 논문에서는 심전도신호에서 R-peak를 검출하여, R-R 간격을 구하고 부정맥 중에 서맥(bradycardia)과 빈맥(tachycardia) 구간을 검출하는 알고리즘을 제안하고 모의실험을 하였다.

액티브 러닝 학습방법을 활용한 심전도 개론 및 실습 교과과정의 학습효과와 만족도 조사 (Outcomes of active learning methods in an electrocardiography course; identifying the effects of flipped, case-based, and team-based learning)

  • 김철태;김정선
    • 한국응급구조학회지
    • /
    • 제23권2호
    • /
    • pp.61-73
    • /
    • 2019
  • Purpose: This study aimed to introduce active learning methods, including flipped, case-based, and team-based learning in an electrocardiography (ECG) course and to investigate outcomes and satisfaction with these methods. Methods: To identify the learning effect of active learning, pre-and post-academic self-efficacy was compared between the experimental and control groups. In the experimental group, pre-and post-knowledge and clinical performance regarding ECG were also assessed. In addition, class satisfaction was investigated after application of active learning methods in the experimental group. Data were collected from 84 paramedic students and analyzed using SPSS 22.0 (IBM, Armonk, NY, USA). Results: The experimental group showed significant improvement in post-academic self-efficacy and knowledge. The experimental group also showed high clinical performance (9.83 out of 10 in ECG checking ability and 9.63 out of 10 in ECG reading ability). The mean satisfaction score was 4.23 out of 5 (responses based on a Likert scale) in the experimental group. Conclusion: Active learning in an ECG course was found to be highly effective and satisfactory. Furthermore, paramedic students can enhance their accountability and judgement with team-based learning through free engagement in discussion.

Electrocardiography as an early cardiac screening test in children with mitochondrial disease

  • Baik, Ran;Chae, Jung-Hyun;Lee, Young-Mock;Kang, Hoon-Chul;Lee, Joon-Soo;Kim, Heung-Dong
    • Clinical and Experimental Pediatrics
    • /
    • 제53권5호
    • /
    • pp.644-647
    • /
    • 2010
  • Purpose: To evaluate myocardial conductivity to understand cardiac involvement in patients with mitochondrial disease. Methods: We performed retrospective study on fifty-seven nonspecific mitochondrial encephalopathy patients with no clinical cardiac manifestations. The patients were diagnosed with mitochondrial respiratory chain complex defects through biochemical enzyme assays of muscle tissue. We performed standard 12-lead electrocardiography (ECG) on all patients. Results: ECG abnormalities were observed in 30 patients (52.6%). Prolongation of the QTc interval (>440 ms) was seen in 19 patients (33.3%), widening of the corrected QRS interval in 15 (26.3%), and bundle branch block in four (7.0%). Atrioventricular block, premature atrial contraction and premature ventricular contraction were seen in two patients each (3.5%) and Wolff-Parkinson-White syndrome in one patient (1.8%). Conclusion: Given this finding, we recommend active screening with ECG in patients with mitochondrial disease even in patients without obvious cardiac manifestation.