Abstract
This paper presents flexible electrocardiography(ECG) sensors using micro electro mechanical systems(MEMS) and flexible printed circuit(FPC) technology. By using FPC technology, ECG sensors which consisted of an outer hook-shaped electrode and an inner circular-shaped electrode were fabricated on the polyimide substrate. Thereafter, the bipolar ECG sensor was miniaturized using MEMS technology. The ECG measurement capability was examined by attaching the sensor to the human chest and wrist. Performance of the proposed sensors was then compared with ECG measured by commercial Ag/AgCl electrodes. It was verified that ECG could be measured using proposed sensors at only single body.
Keywords
electrocardiography sensor; flexible printed circuit; polyimide substrate; MEMS;
Citations & Related Records
연도 인용수 순위
  • Reference
1 W. Besio and T. Chen, 'Tripolar laplacian electrocardiogram and moment of activation isochronal mapping', Physiological Measurement, vol. 28, no. 5, pp. 515-529, 2007   DOI   ScienceOn
2 E-S Hwang, Y-J Kim, and B-K Ju, 'Flexible polysilicon sensor array modules using ‘etch-release’ packaging scheme', Sensors and Actuators A, vol. 111, issue 1, pp. 135-141, 2004   DOI   ScienceOn
3 J-Y Baek, J-H An, J-M Chio, K-S Park, and S-H Lee, 'Flexible polymeric dry electrodes for the long-term monitoring of ECG', Sensors and Actuators A, vol. 143, issue 2, pp. 423-429, 2008   DOI   ScienceOn
4 W-Y Chang, T-H Fang, and Y-C Lin, 'Characterization and fabrication of wireless flexible physiological monitor sensor', Sensors and Actuators A, vol. 143, issue 2, pp. 196-203, 2008   DOI   ScienceOn
5 김용호, 김용준, '유연인쇄회로기판 기술을 이용한 이전극형 심전도 센서', 한국정밀공학회 2007년도 춘계학술대회논문집, pp. 699-700, 제주, 한국, 2007
6 B. H. and R. J. Cohen, 'Body surface laplacian ECG mapping', IEEE Transactions on Biomedical Engineering, vol. 39, no. 11, pp. 1179-1191, 1992   DOI   ScienceOn
7 C-C Lu and P. P. Tarjan, 'Pasteless, active, concentric ring sensors for directly obtained laplacian cardiac electrograms', J. of Medical and Biological Engineering, vol. 22, no. 4, pp. 199-202, 2002
8 T. F. Oostendorp and A. van Oosterom, 'The surface laplacian of the potential : theory and application', IEEE Transactions on Biomedical Engineering, vol. 43, no. 4, pp. 394-405, 1996   DOI   ScienceOn