Thermal and Mechanical Properties of Electro-Slag Cast Steel for Hot Working Tools

  • Moon Young Hoon;Kang Boo Hyun;Van Tyne Chester J.
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.496-504
    • /
    • 2005
  • The thermal and mechanical properties of an electro-slag cast steel of a similar chemical composition with an AISI-6F2 steel are investigated and compared with a forged AISI-6F2 steel. AISI-6F2 is a hot-working tool steel. Electro-slag casting (ESC) is a method of producing ingots in a water-cooled metal mold by the heat generated in an electrically conductive slag when current passes through a consumable electrode. The ESC method provides the possibility of producing material for the high quality hot-working tools and ingots directly into a desirable shape. In the present study, the thermal and mechanical properties of yield strength, tensile strength, hardness, impact toughness, wear resistance, thermal fatigue resistance, and thermal shock resistance for electro-slag cast and forged steel are experimentally measured for both annealed and quenched and tempered heat treatment conditions. It has been found that the electro-slag cast steel has comparable thermal and mechanical properties to the forged steel.

Effect of pre-magneto-electro-mechanical loads and initial curvature on the free vibration characteristics of size-dependent beam

  • Arefi, M.
    • Structural Engineering and Mechanics
    • /
    • v.71 no.1
    • /
    • pp.37-43
    • /
    • 2019
  • This paper studies application of modified couple stress theory and first order shear deformation theory to magneto-electro-mechanical vibration analysis of three-layered size-dependent curved beam. The curved beam is resting on Pasternak's foundation and is subjected to mechanical, magnetic and electrical loads. Size dependency is accounted by employing a small scale parameter based on modified couple stress theory. The magneto-electro-mechanical preloads are accounted in governing equations to obtain natural frequencies in terms of initial magneto-electro-mechanical loads. The analytical approach is applied to investigate the effect of some important parameters such as opening angle, initial electric and magnetic potentials, small scale parameter, and some geometric dimensionless parameters and direct and shear parameters of elastic foundation on the magneto-electro-elastic vibration responses.

Development of Regenerative Inverter for Electric Railway Using Space Vector PWM (SVPWM을 이용한 전기철도용 회생 인버터 개발)

  • Jung M.G.;Baek B.S.;Kim T.W.;Ryu S.P.;Kim N.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.15-18
    • /
    • 2003
  • The electric power, regenerated while railway vehicles braking or running downhill, makes U line voltage rise and the feeding system may not be secure. In order to keep away from these kind of insecurity, the regenerative energy should be consumed by loads or transmitted to the AC side via certain devices such as DC/AC converters. This paper introduces the developed regenerative inverter for electric railway.

  • PDF

A New Velocity Measurement Method using Linear Type Hall-effect Sensor for Electro-mechanical Fin Actuator (선형홀센서를 이용한 전기식 구동장치의 속도 신호 구현)

  • Gu, Jeong-Hoi;Song, Chi-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.1
    • /
    • pp.70-75
    • /
    • 2010
  • The objective of this paper is to propose a new velocity measurement method for an electro-mechanical fin actuator. The model of the electro-mechanical fin actuator includes uncertainties such as unknown disturbances and parameter variations in flight condition. So, an electro-mechanical fin actuator system needs robust control algorithm which requires not only position information but also velocity information. Usually, analog tachometers have been used for velocity feedback in an electro-mechanical fin actuator. However, using these types of sensors have problems such as the cost, space, and malfunction. These problems lead to propose a new velocity measurement method using linear type Hall-effect sensor. In order to verify the proposed method, several experiments are performed using Model Following Sliding Mode Controller(MFSMC). It is shown that the MFSMC with a new velocity measurement method using linear type Hall-effect sensor can satisfy the requirements without using of velocity sensor.

3D Electric Field Analysis for the Standardization of the Insulation Design of GIS (초고압차단기 절연설계 표준화를 위한 3차원 전계해석)

  • Kim, J.S.;Choi, M.J.;Choi, Y.C.;Kim, I.M.;Kim, J.G.;Park, I.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.687-689
    • /
    • 2001
  • In this study, BIEM(Boundary Integral Equation Method) using Green's function is applied in order to analyze 3D electric field precisely. The algorithm is developed with equivalent electric surface charge as a variable, which promises less unknown variables and higher accuracy of electric field analysis. The validity of the developed program is varified by applying it to a coaxial cylinder mode and 3-phase GIS model.

  • PDF

Application of the RC Filter for Suppressing the Output Overvoltage of the High-voltage Large-capacity Inverter (고압 대용량 인버터의 출력 과전압 억제를 위한 RC filter의 현장적용 시험에 관한 연구)

  • Woo, Myung-Ho;Park, Young-Min;Lee, Se-Hyun;Min, Byung-Duk;Seo, Kwang-Duk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.962-964
    • /
    • 2001
  • In this paper, the RC filter for mitigating the output overvoltage of the 3-level 3300V 4MW inverter is described. The descriptions on power circuit and overvoltage phenomena are presented. The output transformer which may be used to obtain the higher output voltage, makes the filter design difficult because the parameter measurements are not easy and the accuracy may be poor. So, this paper presents several preliminary results on the output overvoltage with or without transformer to investigate the overall system characteristics. Some experimental results are also provided when the designed filter is applied.

  • PDF

A Study on the Optimal Design for DC traction system of Light Rail Transit (경전철 급전시스템의 최적설계에 관한 연구)

  • Jeon, Yong-Joo;Cho, Sung-Joon;Baek, Byung-San;Kim, Kuk-Jin;Kim, Jong-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1251-1253
    • /
    • 2001
  • This paper presents on capacity design of DC-fed-traction system. The system is introduced including a characteristics of train, feeding network configuration, and design method of substation arrangements. Optimal design procedures is described, and program for capacity computation of the system is presented using the nodal equation, K.C.L, K.V.L, Ohm's law and superposition theory. For the proof of the proposed algorithm, we accomplished the simulation of DC traction system for HA-Nam LRT. By considering whole component in DC traction system the conclusion will be much precise.

  • PDF

Estimation of Bubble Behavior and PD Initiation Voltage in the Simulated Electrode System of High Temperature Superconducting Coils (고온초전도코일 모의전극계에서 기포거동 및 부분방전개시전압의 추정)

  • Seok, Bok-Yeol;Choi, Myung-Joon;Kim, Yong-Han;Kim, Jin-Soo;Kim, Jong-Koo
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1771-1773
    • /
    • 2001
  • This paper deals with the numerical estimation of the bubble behavior and the partial discharge(PD) initiation voltage basis of electric field calculation with the coaxial coil layer-to-cylindrical electrode system for the simulation of high temperature superconducting coils. The theoretical results of bubble behavior and the PD initiation voltages showed fairly good agreements with the experimental results.

  • PDF

A Design of DVR's Control Algorithm (DVR제어알고리즘 개발)

  • Lee, S.D.;Lee, S.J.;Kim, M.C.;Lee, H.W.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.283-286
    • /
    • 2001
  • 본 논문은 전력 품질개선장치인 DVR(Dynamic Voltage Restorer)시스템의 제어알고리즘 개발에 관한 것이다. DVR은 배전전계통에 직렬변압기를 통해 설치되어 전원의 순간전압강하(Voltage sag)를 보상하는 장치이며 전력변환장치 직렬변압기 에너지저장장치, 충전장치, 보호장치등으로 구성된다. 지락사고, 비선형부하의 순간투입, 뇌서지등 여러 요인에 의해 3상전원에서 발생하는 다양한 형태의 전압sag 보상이 가능한 제어알고리즘 모델을 제시하고 컴퓨터시뮬레이션을 통해 기본성능을 확인한 후 소형 DVR을 제작해 시험하였으며 이시험결과를 실 용량 DVR시제품의 설계에 이용하였다.

  • PDF

The Development of Remote Management System for GIS Preventive Diagnosis System (GIS 예방진단 시스템용 원격관리시스템 개발)

  • Min, B.W.;Myoung, H.C.;Choi, H.W.;Lee, B.H.;Kim, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2065-2066
    • /
    • 2008
  • GIS 예방진단 시스템을 현장에 적용할 경우 예상치 못한 노이즈와 전기외란으로 예측 일치율에 저하가 발생한다. 본 논문에서는 각 현장에 설치된 온라인 GIS예방진단 시스템의 기록정보를 받아들여 새롭게 학습을 시킴으로써 현장 적응형 진단을 구축할 수 있는 방안을 제시한다. 또한 현장의 각종 노이즈 패턴도 학습시킴으로써 진단엔진의 성능향상을 도모한다.

  • PDF