• 제목/요약/키워드: electricity saving methods

검색결과 17건 처리시간 0.03초

전기절약방법의 효과에 대한 소비자인식과 실천행동에 관한 연구 (Consumer Perceptions on the Effects of Electricity Saving Methods and Electricity Saving Behavior)

  • 이성림;박명희;이은영
    • 가정과삶의질연구
    • /
    • 제26권4호
    • /
    • pp.1-11
    • /
    • 2008
  • This study investigated consumers' energy saving behavior and perceptions concerning the effectiveness of their energy saving behavior. A nation wide survey was conducted involving 2000 households in urban areas and the data from 1767 households were used for the analysis. excluding cases with incomplete responses. Descriptive analysis, factor analysis, and regression analysis were applied. The results were as follows. First, electricity saving behavior was classified into three categories: Thrift (reducing energy consumption), Purchase (buying energy saving appliances), and Control (checking the energy consumption). Second, consumers rated Thrift as the best way to save energy. Third, education, age, and household income were significantly related to energy saving behavior and perceptions on the effectiveness of energy saving behavior. Consumers using above average levels of electricity tended not to practice energy saving behavior and not to positively evaluate effectiveness of the energy saving behavior. Lastly, the implications for public policies to promote energy saving behavior are suggested.

공동주택 건축계획요소에 따른 전기 에너지 소비특성 분석 - 서울지역의 40평형(132~165㎡)의 단위세대 전기에너지 사용량을 중심으로 - (Analysis on Electricity Consumption Characteristics of Apartments based on Architectural Planning Factors - foused on Households with a total area of 132~165㎡ in Seoul-)

  • 박소윤;이윤재;이현수
    • KIEAE Journal
    • /
    • 제11권5호
    • /
    • pp.107-117
    • /
    • 2011
  • This paper aims to analyze architectural planning factors that could contribute to reductions in electricity consumption in the household of apartments, to apply energy saving methods at the design phase. These six architectural planning factors were orientation, building type (flat, tower block), standard floor access type (corridor access type, stair case type, EV hall access type), household location (floor), household opening type (one side opening, right angle opening, two sides opening or three sides opening), and bay on the facade (one bay, two bays, three bays, four bays), and these were derived from literature review. Household electricity consumption data were gathered from 2168 households with a total area of 135~150$m^2$ of 6 apartment complexes over 1000 households in Seoul. The annual characteristics of electricity consumption according to architectural planning factors were analyzed. And, variances between groups with respect to the mean of summer, winter, and annual electricity consumption according to each architectural planning factors were analyzed using ANOVA and t-test. The results showed that an annual electric energy saving of over 1000kWh was facilitated by these planning factors. In addition, high energy efficiency architectural planning factors based on the analysis were as follows: southwest orientation, flat type, corridor access type and staircase type, household loation below the 20th floor, two sides opening and three sides opening, and 2 bays and 3 bays.

Planning ESS Managemt Pattern Algorithm for Saving Energy Through Predicting the Amount of Photovoltaic Generation

  • Shin, Seung-Uk;Park, Jeong-Min;Moon, Eun-A
    • 통합자연과학논문집
    • /
    • 제12권1호
    • /
    • pp.20-23
    • /
    • 2019
  • Demand response is usually operated through using the power rates and incentives. Demand management based on power charges is the most rational and efficient demand management method, and such methods include rolling base charges with peak time, sliding scaling charges depending on time, sliding scaling charges depending on seasons, and nighttime power charges. Search for other methods to stimulate resources on demand by actively deriving the demand reaction of loads to increase the energy efficiency of loads. In this paper, ESS algorithm for saving energy based on predicting the amount of solar power generation that can be used for buildings with small loads not under electrical grid.

Simultaneous water and energy saving of wet cooling towers, modeling for a sample building

  • Ataei, Abtin;Choi, Jun-Ki;Hamidzadeh, Zeinab;Bagheri, Navid
    • Advances in environmental research
    • /
    • 제4권3호
    • /
    • pp.173-181
    • /
    • 2015
  • This article outlines a case study of water and energy savings in a typical building through a modelling process and analysis of simultaneous water-energy saving measures. Wet cooling towers are one of the most important equipments in buildings with a considerable amount of water and energy consumption. A variety of methods are provided to reduce water and energy consumption in these facilities. In this paper, thorough the modeling of a typical building, water and energy consumption are measured. Then, After application of modern methods known to be effective in saving water and energy, including the ozone treatment for cooling towers and shade installation for windows, i.e. fins and overhangs, the amount of water and energy saving are compared with the base case using the Simergy model. The annual water consumption of the building, by more than 50% reduction, has been reached to 500 cubic meters from 1024 cubic meters. The annual electric energy consumption has been decreased from 405,178 kWh to 340,944 kWh, which is about 16%. After modeling, monthly peak of electrical energy consumption of 49,428 has dropped to 40,562 kWh. The reduction of 18% in the monthly peak can largely reduce the expenses of electricity consumption at peak.

전기에너지주택의 유동적인 실험환경을 고려한 가전기기 제어 시뮬레이션 방안에 관한 연구 (A Study on the Control Simulation Method of Home Appliances Considering the Flexible Experimental Condition of All-Electrified Houses)

  • 황성욱;김강식;나환선;조병옥
    • 한국기계기술학회지
    • /
    • 제13권1호
    • /
    • pp.57-64
    • /
    • 2011
  • Recently, all-electrified houses have constructed and some tasks are being carried out to monitor energy consumption patterns. The energy monitoring includes various elements such as temperature, pressure, water flow, $CO_2$, and electricity. In this monitoring, electricity consumption is one of the essential factors because the performance and energy saving levels are described by this physical quantity. This quantity depends on materials, structure, operation of the house, which operation means consumer's life style and usage patterns of home appliances furthermore. Firstly, this paper shows a control simulation method which were developed a few years ago. And some different methods are proposed considering flexible experimental condition.

중앙난방시스템의 유량제어방식에 따른 제어특성 연구 (Control Characteristics with Flow Rate Control Methods in Central Heating System)

  • 송재엽;안병천
    • 한국지열·수열에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.32-37
    • /
    • 2011
  • In this study, control characteristics and energy performance with flow rate control methods were reviewed with the simulation. The heating system is classified such as fan coil unit and HVAC system currently used in buildings with valve control and pump inverter control. The simulation analysis program is made by TRNSYS ver. 15 with the actual data. As a result of this study, the central heating system with pump inverter control decreases electricity energy and reduces gas consumption. Inverter control method shows better performance in comparison with valve control one for energy saving.

OA기기의 대기전력 측정을 통한 절전 평가 제안 (The Recommendation on Power Saving through the Measuring of the Standby Power of OA Equipments)

  • 김만건;최돈묵
    • 대한안전경영과학회지
    • /
    • 제15권1호
    • /
    • pp.161-167
    • /
    • 2013
  • The purpose of this study was to assess power loss in the computer and office automation equipment and identified a way to save power consumptions through field measurement. In this study, the meaning of standby power was to consume power while waiting for the use of any electronic equipment. This standby consumption was about 11% of total power consumption even though we did not seriously realize it. Therefore, it was very important to measure accurate power consumption at the standby status of electronic equipment. In addition, it also helped to reduce potential risks of electricity associated disasters. This study proposed the way to reduce power losses through automatic turn off switches for power outlets and switches. Finally, this study can evaluate power consumption patterns that can reduce power consumptions and potential risks of power related disasters. This also can achieve the goals of sustainability that can reduce environmental impacts by lowering energy consumptions and greenhouse gas emissions.

교육기관 지능형 수배전반의 구성방식과 현황분석 (Construction form and status analysis of intelligent type switching board of educational institution)

  • 최인호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.393-396
    • /
    • 2007
  • Recently one level higher intelligent switching board than established one by the application of intelligent building and digital system are being constructed. Therefore facility's high efficiency, high degree satisfaction, miniaturaization, standardization through application of communication technology and monitoring and controlling by computer system utilized by web-basis power control system and electric IT are practiced. Especially network must be constructed through unified IBS server that monitors every educational institute's switching boards in real time control system. And I intend to create methods to save energy and raise electricity quality by power demand prediction and remote-controled management and operation. In this thesis I intend to suggest measures of forming unified system through researching educational institute's ways of constructing switching board and status analysis and overcoming technical difficulties in user's side and saving and maintenance expense.

  • PDF

Demand Response Impact on Market Operator's Revenue and Load Profile of a Grid Connected with Wind Power Plants

  • Tahmasebi, Mehrdad;Pasupuleti, Jagadeesh
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.46-52
    • /
    • 2013
  • Economic properties of an integrated wind power plant (WPP) and the demand response (DR) programs in the sample electricity market are studied. Time of use (TOU) and direct load control (DLC) are two of the DR programs that are applied in the system. The influences of these methods and the incentive payments by market operator's (MOs) with variable elasticity are studied. It is observed that DR with TOU and DLC programs together yields better revenue and energy saving for MOs.

급속충전방식 무가선 전동차 시스템을 이용한 전기요금 절감 방안 연구 (Study of Electric Charge Saving Plan Using High-speed Charging Wireless Railway System)

  • 고효상;조인호;류준형;김길동
    • 한국철도학회논문집
    • /
    • 제20권1호
    • /
    • pp.31-42
    • /
    • 2017
  • 철도 시스템의 전력 소비를 줄이기 위한 많은 연구가 진행되고 있다. 그 중에서 급속충전방식 무가선 전동차 시스템은 철도 분야에서 매우 효율적인 에너지 절감 기술로 주목 받고 있다. 본 논문에서는 ESS를 이용한 급속충전 무가선 전동차 시스템을 소개하고 현재의 도시철도 전기요금 산정방식에 대하여 분석하였다. 이러한 분석을 바탕으로 급속 충전 무가선 전동차 시스템 적용 가능한 두 가지 전기요금 저감 방안(기본요금을 저감하는 방식(Case 1)과 전력량요금을 저감시키는 방식(Case 2))을 제안하였다. 제한하는 방식의 타당성 확인을 위해 현재 운영 중인 전동차 시스템(도시철도 2호선)의 전기요금과 비교하여 비용 경제성을 평가하였다.