• Title/Summary/Keyword: electrical wires

Search Result 432, Processing Time 0.027 seconds

Applicability of Messenger Wire for Purpose of Lightning Protection

  • Seo, Hun Chul;Han, Joon;Choi, Sun Kyu;Lee, Byung Sung;Rhee, Sang Bong;Kim, Chul Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.167-174
    • /
    • 2016
  • The Korean distribution line currently consists of overhead ground wires (OHGW), overhead distribution lines, neutral wires (NW), and messenger wires (MW). The MW is installed under the NW. The lightning protection system in Korea is focused on OHGW and lightning arrester and the MW are not considered. Therefore, this paper proposes the applicability of MW for purpose of lightning protection. For this, we analyzed the effects of lightning overvoltage according to the existence of OHGW and MW and the grounding conditions of the MW in the Korean distribution system. The grounding conditions of the MW that we took into consideration were the common or separate grounding of the MW and NW. The analysis based on the equivalent circuit of the distribution pole at each condition was performed. The distribution lines and lightning were modeled using the Electromagnetic Transients Program (EMTP). For each of the installation conditions of the OHGW and MW, the various lightning conditions were simulated and analyzed for both direct and indirect lightning. The simulation results showed that, if the OHGW was not installed in the Korean distribution system, the lightning overvoltage could be reduced by the common grounding of the MW and NW.

Analysis of Thermal Characteristic for Wiring at Heater Connector of Semiconductor Chiller Equipment (반도체 공정 칠러 장비의 히터 접속부 전기배선에 대한 열적 특성 분석)

  • Gyu Bin Kim;Doo-Hyun Kim;Sung-Chul Kim
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.3
    • /
    • pp.27-34
    • /
    • 2023
  • With the technological development of the semiconductor industry, the roles of electrical and thermal energy supply and control of semiconductor equipment in ultrafine processes have become very important. However, instances of electrical fires in the chiller heater, which is used for cooling in the semiconductor manufacturing process, are increasing. A fire occurs in combustibles due to high heat at the connection part of the chiller heater, that is, when the number of electrical wires in the connection part is reduced or when the wires are completely disconnected. In this study, the temperature characteristics were compared and analyzed through experiments and 3D simulations. The number of electrical wires, which is the connection part of the chiller heater, was reduced by 90%, 50%, 30%, 10%, and 5%, and the wires were completely disconnected. When the number of electrical wires was reduced by 5%, heat of up to 80℃ was generated, which is a relatively high temperature but insufficient to cause a fire in combustibles. Complete disconnection occurred due to the vibration of the motor and other components, and sparks and arcs were generated, resulting in a rapid increase in temperature to up to 680℃. When completely disconnected, the temperature increase was sufficient to cause a fire in the combustibles covering the terminal block. Therefore, in this study, the causes of electrical fires in chiller heaters were investigated and preventive measures were proposed by analyzing abnormal signals and thermal characteristics caused by the electrical wiring being reduced and completely disconnected.

Performance of the Squirrel Cage Induction Motor with High Temperature Superconducting Rotor Bars at Stable Operating Region (고온초전도단락봉을 사용한 농형유도전동기의 안정영역 특성)

  • 심정욱;차귀수;이지광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.9
    • /
    • pp.442-447
    • /
    • 2003
  • Motors with HTS wires or bulks have been developing recently. Those are large synchronous motor with HTS wires at the field winding in the rotor, hysteresis and reluctance motors with HTS bulk in the rotor. This paper presents the fabrication and test results of an HTS induction motor. Conventional end rings and short bars were replaced with HTS wires in the motor. Stator of the conventional induction motor was used as the stator of the HTS motor. Rated capacity and rpm at full rotor of the conventional motor were 0.75[kW] and 1,710[rpm]. Two, HTS wires are used in parallel to make the end rings and bars. The critical current of the BSCCO-2223 HTS wire which was used in the bars and end rings were 115[A]. Electrodynamometer was coupled directly to the shaft of the rotor with HTS wires.

Magnetic Field Properties About Core Change (코어 변화에 대한 자계 특성)

  • Kim, Ki-Joon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.2
    • /
    • pp.159-164
    • /
    • 2012
  • In this paper, it tried to develop the core sensor for detection of micro magnetic field in electric wires. The sensor is non contact type and is consisted of ferrite core for low price. To investigate their properties for variations of current, it changed the number of winding and the length of sample core, it examined, to check the live wire situation in built-in wires, electrical characteristics due to difference between electric wires and core sensor. As the results, it verified live wire situation at the number of winding(5,000) and within length of 6[cm]. Also, it obtained magnetic field magnitude decreased inverse proportion ratio to a square about difference between electric wires and core sensor.

Characteristics of AC loss of Hybrid Multi-Stacking with HTS Wires in External Magnetic Field (고온초전도 혼합적층선재의 외부자장 변화에 따른 손실 특설)

  • Lim, Hyoung-Woo;Lee, Dong-Min;Yun, Ki-Hyun;Cha, Guee-Soo;Lee, Hee-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.71-73
    • /
    • 2006
  • AC loss on variation of external magnetic field is a very important factor in development of power applications. In this paper, we measured and compared AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires and uniform-multi-stacked wire made of one type of wires, 1G wires or 2G wires. Measurement was performed using by the linked-picked coil method. As results, as the number of wires increase, AC loss per unit volume of both stacked wires in low external magnetic field is reduced. Also AC loss of 2G slacked wire is higher than that of 1G wire. AC loss per unit length of 2G stacked wire is less than that of 1G stacked wire. And AC loss of hybrid-multi stacked wire made of the combination of 1G wires and 2G wires was between uniform-multi-stacked wire made of 1G wires and 2G wires.

  • PDF

Field Application of Recycled Aluminum Wires (재생 ACSR 전선의 실계통 적용)

  • Kim, Ju-Yong;Kim, Sang-Joon;Song, Il-Keun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1396-1398
    • /
    • 1997
  • This paper presents experimental results on the recycling aluminum wires used in the actual field. Several testings were carried out with the recycled aluminum wires to prove that they are reusable. Mechanical, electrical and oxidation properties of recycled and new ACSR $160\;mm^2$ were campared after 7.5 year service aging at the salt comtaminated areas of Korean peninsular.

  • PDF

Installation of 400kV Underground cable with insulated wires conductor (소선절연도체를 적용한 400KV 지중송전선로의 설치공사)

  • Kim, Hyun-Joo;Kim, Do-Young;Ahn, Kang-Seok;Seo, Sang-Hoon;Park, Keun-Ryong
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1601-1602
    • /
    • 2011
  • 전 세계적으로 매년 증가하고 있는 전력수요는 높은 부하밀도와 함께 송전계통의 대용량화를 필요로 하고 있다. 단순히 송전회전의 증가를 통한 송전계통의 대용량화는 비용의 증가를 초래하며, 과밀화된 도심에서의 경과지 확보와 환경적인 악영향에 대한 우려 등으로 어려움에 직면하고 있다. 따라서, 높은 부하밀도의 수용가가 집중된 송전계통의 대용량화는 보다 적은 비용과 환경적 영향을 고려하여 지중송전 케이블의 적용이 필요하며, 이러한 특수목적의 송전을 위하여 고효율, 대용량화의 여러 기술이 연구 개발되어 적용 중이며, 일부 기술은 상용화 단계에 있다. 본 논문은 지중송전 케이블의 대용량화 기술 중에 도체의 교류저항을 저감하여 저손실과 대용량 송전이 가능한 소선절연도체(Conductor with insulated wires 또는 Enamelled wires)의 개발과 설치공사에 대하여 기술하고자 한다.

  • PDF

Thermomechanical and electrical resistance characteristics of superfine NiTi shape memory alloy wires

  • Qian, Hui;Yang, Boheng;Ren, Yonglin;Wang, Rende
    • Smart Structures and Systems
    • /
    • v.30 no.2
    • /
    • pp.183-193
    • /
    • 2022
  • Structural health monitoring and structural vibration control are multidisciplinary and frontier research directions of civil engineering. As intelligent materials that integrate sensing and actuation capabilities, shape memory alloys (SMAs) exhibit multiple excellent characteristics, such as shape memory effect, superelasticity, corrosion resistance, fatigue resistance, and high energy density. Moreover, SMAs possess excellent resistance sensing properties and large deformation ability. Superfine NiTi SMA wires have potential applications in structural health monitoring and micro-drive system. In this study, the mechanical properties and electrical resistance sensing characteristics of superfine NiTi SMA wires were experimentally investigated. The mechanical parameters such as residual strain, hysteretic energy, secant stiffness, and equivalent damping ratio were analyzed at different training strain amplitudes and numbers of loading-unloading cycles. The results demonstrate that the detwinning process shortened with increasing training amplitude, while austenitic mechanical properties were not affected. In addition, superfine SMA wires showed good strain-resistance linear correlation, and the loading rate had little effect on their mechanical properties and electrical resistance sensing characteristics. This study aims to provide an experimental basis for the application of superfine SMA wires in engineering.

A Study on the Identification of Electrical Eire -Focused on Distance Analysis of Electrical Wires by Overcurrent- (전기화재의 감식에 관한 연구 -과전류 사고시 전선의 이격거리 분석을 통하여-)

  • 이상호;김준식;오홍석
    • Fire Science and Engineering
    • /
    • v.18 no.2
    • /
    • pp.7-11
    • /
    • 2004
  • In this paper, we have simulated the force between the two electrical wires using the finite element method(FEM) according to the value of current and distance when overcurrent flows in the vinyl-insulated vinyl-cabtyre cord(flat-type, 600 V, VCTFK, $2C{\times}1.25mm^2$). And we will present the basic data for the identification of electrical fire by experiment for maximum distance between the two wires according to current and time using large current supply device(Model : EHT_EFAD, Korea) in case of overcurrent.

Development of H/W and S/W for Detecting Electrical Fire Precursor Signal on Electrical Wirings (배선에서 전기화재 전조신호 검출을 위한 H/W 및 S/W 구축)

  • Kim, Sung-Chul;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.13-18
    • /
    • 2009
  • This paper is purposed to develop DAQ H/W, S/W and DB which can be used in developing electrical fire alarm system or in analyzing electrical fire cause, by detecting and monitoring precursor signals which have high possibility leading to electrical fire on electrical distribution wires. In this paper, developed was DAQ H/W adopting the C8051FXXX CPU which can analyze the measurement signals of current and voltage in electrical distribution wires, other CPU was investigated in view of the best digital sampling rate on the basis of previous researches for electrical fire alarm system. Also, the S/W which can interface with DAQ H/W's communication protocol and can be applied for electrical fire causes analysis, are embodied by LabVIEW. The combined DAQ H/W and S/W could analyze efficiently normal as well as abnormal electrical signals such as RMS value, instantaneous value of current and voltage, frequency signals etc, on the electrical wires. Also, DB system was constructed for recording various analysis results for precursor signals including voltage and current signals. The results by simulator and experiment showed that the suggested scheme with DAQ H/W, S/W and DB in this paper has high usability.