• 제목/요약/키워드: electrical tree

검색결과 591건 처리시간 0.031초

지중배전선로의 고장전류 크기 및 보호협조분석 (Ananalzing fault current and Protective coordination in the underground line)

  • 조남훈;하복남;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

효율적인 타이밍 수준 게이트 지연 계산 알고리즘 (An Efficient Timing-level Gate-delay Calculation Algorithm)

  • 김부성;김성만;김석윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.603-605
    • /
    • 1998
  • In recent years, chip delay estimation has had an increasingly important impact on overall design technology. The analysis of the timing behavior of an ASIC should be based not only on the delay characteristics of gates and interconnect circuits but also on the interactions between them. This model plays an important role in our CAD system to analyze the ASIC timing characteristics accurately, together with two-dimensional gate delay table model, AWE algorithm and effective capacitance concept. In this paper, we present an efficient algorithm which accounts for series resistance by computing a reduced-order approximation for the driving-point admittance of an RC-tree and an effective capacitance equation that captures the complete waveform response accurately.

  • PDF

전기도금법에 의한 백금 흑 수광체 제조 (Preparation of Pt-Black Absorber by Electroplating)

  • 배성호;이상만;이문호
    • 한국결정학회지
    • /
    • 제7권2호
    • /
    • pp.133-146
    • /
    • 1996
  • 전기 도금법으로 제조한 백금흑의 형상과 적외선 흡수특성을 XRD, SEM, IR 분광기를 사용하여 조사하였다. 금(Au)이 입혀진 알루미나 유리기판 위에 pH 1.0∼1.5에서 1∼5분동안 백금층을 입혔는데, 염화백금과 아세트산 납으로 제조한 용액을 전해액으로 사용하였다. 전류밀도가 20∼50 mA/㎠일 때 백금흑은 수지상으로 성장하여 "나무"와 같은 형태를 보였다. 백금흑의 면적밀도가 1.3mg/㎠ 이상일 때 10μm의 적외선에서 측정한 수광효율은 90% 이상이었다.

  • PDF

Recent Successive Cancellation Decoding Methods for Polar Codes

  • Choi, Soyeon;Lee, Youngjoo;Yoo, Hoyoung
    • Journal of Semiconductor Engineering
    • /
    • 제1권2호
    • /
    • pp.74-80
    • /
    • 2020
  • Due to its superior error correcting performance with affordable hardware complexity, the Polar code becomes one of the most important error correction codes (ECCs) and now intensively examined to check its applicability in various fields. However, Successive Cancellation (SC) decoding that brings the advanced Successive Cancellation List (SCL) decoding suffers from the long latency due to the nature of serial processing limiting the practical implementation. To mitigate this problem, many decoding architectures, mainly divided into pruning and parallel decoding, are presented in previous manuscripts. In this paper, we compare the recent SC decoding architectures and analyze them using a tree structure.

가교폴리에틸렌의 내부방전효과에 의한 절연파괴특성 (A Study on the Breakdown Characteristics in Cross-linked Polyethylene by Treeing Effect)

  • 곽영순;이양성;조정수
    • 전기의세계
    • /
    • 제27권6호
    • /
    • pp.76-83
    • /
    • 1978
  • This paper reveals the results of fundamental experiments with the breakdown strength- and treeing phenomena, by A.C voltage and impulse voltage, of cross-linked polyethylene insulator, respectively compared in each case of the various specimens; nonvoid, air void, water void, oil void and oil impregnated one, all articially made. In this research, the V-t and V-n characteristics are investigated by means of the Weibull distribution and are analysed the characteristics of fatigue breakdown caused by the A.C and impulse voltage. Based on numerous tests, treeing effect and treeing breakdown mechanism is investigated through microscopic photographs taken to clarify the shapes of each tree and treeing breakdown phenomena.

  • PDF

Simple table 방법에 의한 논리함수 최소화의 신방법 (A new approach to the minimization of switching functions by the simple table method)

  • 황희융
    • 전기의세계
    • /
    • 제28권6호
    • /
    • pp.61-77
    • /
    • 1979
  • This paper is concerned with minimization process of the binary logic function. This paper describes an algorithm called the SIMPLE TABLE METHOD that well suited to minimization a switching function of any number of variables. For the Simple Table construction, a theorem based upon the numerical properties of the logic function is derived from the relationships governing minterms of the given function. Finally the minimal sum of products can be obtained in terms of the Direct Method or the Indirect Method from the table and table characteristics derived from the Simple Table. The properties and table characteristics used in this paper are described. All the minterms of a switching function are manipulated only by decimal numbers, not binary numbers. Some examples are used as a vehicle to guide the readers who are familiar with the Karnaugh map and Quine-McCluskey tabular method to this New method. These examples not only treat how to handle Don't Care miterms but also show the multiple output functions.

  • PDF

14주기 열화에 따른 22.9kV 전력케이블의 교류파괴전압 특성분석 (AC Breakdown Voltage Characteristics for 22.9kV Power Cable Before and After Cyclic Aging for 14days)

  • 김위영;허종철;박태곤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2271-2273
    • /
    • 2005
  • The cyclic aging for 14days is performed in order to remove the large amount of the volatiles contained in freshly manufactured cable. And the accelerated water treeing test(AWTT) is performed to accelerate the occurance of the water tree in the dielectric of XLPE. In this paper, we examined the AC breakdown voltage characteristics of the 22.9kV power cable before and after the cyclic aging for 14days and the AWTT. As the result, the AC breakdown voltage of the TR CNCV-W power cable is higher than that of CNCV-W and FR CNCO-W power cable.

  • PDF

퍼지 논리 적용에 의한 배전계통의 고장 검출 시스템 개발 (Development of a Fuzzy Logic-based Fault Identification System In Distribution System)

  • 김창종;오용택
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.737-739
    • /
    • 1996
  • Abnormal conditions and disturbances in distribution system cause an immediate influence to the customers. Conventional detection schemes for the distribution abnormalities have been applied in limited extents mainly because of their low reliability. In this paper, we developed a disturbance identification system which monitors the load level after a transient, checks the harmonic behavior of the load, and finally makes decision on the cause of the disturbance. This system identifies and discriminates overcurrent faults, arcing ground faults, recloser activities, and foreign object or tree contacts. In the implementation of the identification system, we applied fuzzy logic to better represent some variables whose Quantities are expressed only in non-numerical terms.

  • PDF

지식베이스를 이용한 배전계통의 최적재구성 (The Optimal Distribution Feeder Reconfiguration Using Knowledge Base)

  • 조시형;최병윤;김세호;이재관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.99-101
    • /
    • 1993
  • This paper presents an approach to feeder reconfiguration in order to achieve an efficient operation of distribution systems utilizing knowledge base. The optimal feeder reconfiguration in this study eliminates various abnormal states which will create feeder overloads and feeder constraint problems. and will also accomplish minimum power loss of the distribution systems under normal operating condition by means of branch exchanges to change the status of sectionalizing switches with experiences of the experts. For an effective implementation of feeder reconfiguration, a best-first tree searching strategy based on heuristics is employed to evaluate the various alternatives of load transfer. The heuristic exchange of branches results in reduction of the search space as a means of implementing the best-first searching strategy.

  • PDF

6.6kV CV케이블의 경년열화 특성연구 (A study on the characteristics of deterioration in 6.6kV CV cable)

  • 김광화;선종호;김영배;조연옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.636-639
    • /
    • 1993
  • This paper is discribed the results of insulation characteristic tests that are DC leakage current, test, tan${\delta}$ test, AC breakdown test and observation of tree in the used 6.6kV CV cables. In the correlation of these tests, the tan${\delta}$ test stands for the main deterioration factor of cable insulation.

  • PDF