• Title/Summary/Keyword: electrical test

Search Result 7,395, Processing Time 0.027 seconds

A New Reseeding Methodology Using a Variable-Length Multiple-Polynomial LFSR (가변 길이의 다중 특성 다항식을 사용하는 LFSR을 이용한 새로운 Reseeding 방법)

  • Yang Myung-Hoon;Kim Youbean;Lee Yong;Park Hyuntae;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.3 s.333
    • /
    • pp.35-42
    • /
    • 2005
  • This paper proposes a new reseeding methodology using a variable-rank multiple-polynomial linear feedback shift register (MP-LFSR). In the proposed reseeding scheme, a test cube with large number of specified bits is encoded with a high-rank polynomial, while a test cube with a small number of specified bits is encoded with a low-rank polynomial. Therefore, according to the number of specified bits in each test cube, the size of the encoded data can be optimally reduced. A variable-rank MP-LFSR can be implemented with a slight modification of a conventional MP-LFSR and Multiple Polynomial can be represented by adding just 1 bit to encoding data. The experimental results on the largest ISCAS'89 benchmark circuits show that the proposed methodology can provide much better encoding efficiency than the previous methods with adequate hardware overhead.

Metallizations and Electrical Characterizations of Low Resistivity Electrodes(Al, Ta, Cr) in the Amorphous Silicon Thin Film Transistor (비정질 실리콘 박막 트랜지스터 소자 특성 향상을 위한 저 저항 금속 박막 전극의 형성 및 전기적 저항 특성 평가)

  • Kim, Hyung-Taek
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1993.05a
    • /
    • pp.96-99
    • /
    • 1993
  • Electrical properties of the Thin Film Transistor(TFT) electrode metal films were investigated through the Test Elements Group(TEG) experiment. The main purpose of this investigation was to characterize the electrical resistance properties of patterned metal films with respect to the variations of film thickness and TEG metal line width. Aluminum(Al), Tantalum(Ta) and Chromium(Cr) that are currently used as TFT electrode films were selected as the probed metal films. To date, no work in the electrical characterizations of patterned electrodes of a-Si TFT was accomplished. Bulk resistance$(R_b)$, sheet resistance$(R_s)$, and resistivities($\rho$) of TEG patterned metal lines were obtained. Electrical continuity test of metal film lines was also performed in order to investigate the stability of metallization process. Almost uniform-linear variations of the electrical properties with respect to the metal line displacements was also observed.

  • PDF

Electrical Resistance Measurement in Characterizing the Internal Damage of Carbon Nanotube/Polypropylene Nanocomposites (전기저항 측정법을 이용한 탄소나노튜브/폴리프로필렌 나노복합재료의 내부 손상 예측)

  • Kim, Hak-Soo;Kwon, Dong-Jun;Wang, Zuo-Jia;Gu, Ga-Young;Kim, Dae-Sik;Lee, Chun-Soo;Park, Joung-Man
    • Composites Research
    • /
    • v.26 no.3
    • /
    • pp.201-206
    • /
    • 2013
  • The electrical resistance measurement was investigated as a damage monitoring method. In this study, 0.5 wt% Carbon nanotube reinforced polypropylene (CNT/PP) composites were evaluated under compressive fatigue loading. The shape of specimens was $20^{\circ}$ curved round type. Compression strength and electrical resistance were measured at different sections of specimen during compression. The microcracks of CNT/PP composites were detected based on the changing ratio of electrical resistance. Micro-damage during compressive fatigue test could be detected by electrical resistance measurements. The reason is that the contact points of CNTs in composites decreased under fatigue loading. During compressive fatigue test, larger change of electrical resistance was detected at the microcrack sections. It was proved that microcracks could be detected by electrical resistance measurement under compression test, whereas the real delamination parts were consistent with the predicted results by electrical resistance measurement.

A Study on the Development of Traction Motor for Electric Railway: Insulation System Design & Performance Test

  • Wang, Jong-Bae
    • Transactions on Electrical and Electronic Materials
    • /
    • v.2 no.4
    • /
    • pp.19-23
    • /
    • 2001
  • In this paper, design considerations and manufacturing procedure of 200 class insulation system with polyimide(Kapton) main insulation and silicone resin VPI process on the traction motor thor EMU will be reviewed. The performance test and the long life evaluation test that prove stability and reliability of Insulation system for traction motor will also be introduced.

  • PDF

A Test Vector Reordering for Switching Activity Reduction During Test Operation Considering Fanout (테스트시 스위칭 감소를 위해 팬 아웃을 고려한 테스트벡터 재 정렬)

  • Lee, Jae-Hoon;Baek, Chul-Ki;Kim, In-Soo;Min, Hyoung-Bok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.5
    • /
    • pp.1043-1048
    • /
    • 2011
  • Test vector reordering is a very effective way to reduce power consumption during test application. But, it is time-consuming and complicated processes, and it does not consider internal circuit structure, which may limit the effectiveness. In this paper, we order test vectors using fanout count of primary inputs that consider the internal circuit structure, which may reduce the switching activity. Then, we reorder test test vectors again by using Hamming distance between test vectors. We proposed FOVO algorithm to perform these two ideas. FOVO is an effective way to reduce power consumption during test application. The algorithm is applied to benchmark circuits and we get an average of 3.5% or more reduction of the power consumption.

An Accuracy Analysis of Run-test and RA(Reverse Arrangement)-test for Assessing Surface EMG Signal Stationarity (표면근전도 신호의 정상성 검사를 위한 Run-검증과 RA-검증의 정확도 분석)

  • Lee, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.2
    • /
    • pp.291-296
    • /
    • 2014
  • Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of weak stationarity. The purpose of this study is to analyze the accuracy of the Run-test, modified Run-test, RA(reverse arrangement)-test, and modified RA-test for assessing surface EMG signal stationarity. Six stationary and three non-stationary signals were simulated by using sine wave, AR(autoregressive) modeling, and real surface EMG. The simulated signals were tested for stationarity using nine different methods of Run-test and RA-test. The results showed that the modified Run-test method2 (mRT2) classified exactly the surface EMG signals by stationarity with 100% accuracy. This finding indicates that the mRT2 may be the best way for assessing stationarity in surface EMG signals.

New Inspection Skill for Load-test of Hydraulic Elevator without Actual Loads (엘리베이터 하중시험 대체 검사기법 개발)

  • Heo, Yun-Seop;Eom, Yong-Gi
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.3
    • /
    • pp.127-132
    • /
    • 2013
  • In order to check traction of the elevator, the load-test is positively necessary on the inspection of elevator in Korea. So actual loads are used in the elevator car for the load-test. However, some of advanced countries in Europe, for example Germany, are using the alternative method with no load test instead of traditional load-test. Commonly hydraulic elevator, compared to passenger elevator is mainly used for loading heavy weights. It requires a great deal of labor to carry out load-test. The reason is why we developed a new inspection skill for the load-test of hydraulic elevator without actual loads. The results of studies show that the new method of the load-test can be replace the traditional load-test.

A Synthetic Test Circuit for HVDC Thyristor Valve Test with Simplified Turn-Off Circuit of Auxiliary Thyristor (보조 사이리스터의 턴-오프 회로를 간소화한 HVDC 사이리스터 밸브 시험용 합성시험회로)

  • Jung, Jae-Hun;Goo, Beob-Jin;Jeo, Han-Je;Nho, Eui-Cheol;Han, Byung-Moon;Chung, Yong-Ho;Baek, Seung-Taek
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.475-480
    • /
    • 2014
  • This study proposes a new synthetic test circuit (STC) for HVDC thyristor valve tests. The conventional STC with a 2-phase chopper requires a 3-phase transformer, a 3-phase diode rectifier, and an IGBT to facilitate the off state of an auxiliary thyristor. In the proposed STC, these three components are replaced with one diode and one resistor, which result in the simplified implementation of the hardware of the STC. Simulation and experimental results demonstrate the validity of the proposed scheme.

Electricity Market Design for the Incorporation of Various Demand-Side Resources in the Jeju Smart Grid Test-bed

  • Park, Man-Guen;Cho, Seong-Bin;Chung, Koo-Hyung;Moon, Kyeong-Seob;Roh, Jae-Hyung
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.1851-1863
    • /
    • 2014
  • Many countries are increasing their investments in smart grid technology to enhance energy efficiency, address climate change, and trigger a green energy revolution. In addition to these goals, Korea also seeks to promote national competitiveness, prepare for the growth of the renewable energy industry, and export industrialization through its strategic promotion of the smart grid. Given its inherent representativeness for Korean implementation of the smart grid and its growth potential, Jeju Island was selected by the Korean government as the site for smart grid testing in June 2009. This paper presents a new design for the electricity market and an operational scheme for testing Smart Electricity Services in the Jeju smart grid demonstration project. The Jeju smart grid test-bed electricity market is constructed on the basis of day-ahead and real-time markets to provide two-way electricity transaction environments. The experience of the test-bed market operation shows that the competitive electricity market can facilitate the smart grid deployment in Korea by allowing various demand side resources to be active market players.

Optimization Analysis for Homogeneous Field Structure of GTEM-CELL (GTEM-CELL의 균일한 필드구조를 갖기위한 최적화 분석)

  • Kim, Jong-Seong;Seo, Kang;Jeong, Seong-IL;Lee, Han-Young;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.7 no.2 s.13
    • /
    • pp.218-222
    • /
    • 2003
  • Even if using the standard field test which radiation of electric wave and measurement test equipment there are difficult thing that building test equipment. so, we can use the substitution test field. In this paper, for optimization analysis for homogeneous field structure of GTEM-CELL (Giga hertz Transverse Electro Magnetic Cell) that calculate electromagnetic field characteristic for variable of each structure and characteristic impedance inner conductor.

  • PDF