폐기물매립지 주변의 오염물질 분포 및 이동 특성 (Characteristics of Distribution and Potential Route of Contaminants at Waste Disposal Site)

  • 박성원;황세호;이평구;박인화;신성천;이상규
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 총회 및 춘계학술발표회
    • /
    • pp.144-148
    • /
    • 2001
  • A geophysical and geochemical study was performed to verify the depth of landfill as well as the horizontal/vertical distribution of leachate at the landfill site located in Gongju. The electrical resistivity, with dipole-dipole array and dipole spacing of 5m, was applied along the nine survey lines and electromagnetic induction survey was conducted along the perimeter traverse surrounding the landfill. Cations, anions and stable isotope ($\delta$D and $\delta$$^{18}$ O) analyses were performed on about 63 water and leachate samples collected in dry and rainy seasons at 31 sites. The result of electromagnetic induction survey make it possible to derive the potential route of leachate in the past or present. The imaging of processed resistivity field data show that the possible route of leachate doesn't exist except the survey line 7. The weak zone traversing the landfill, however, is revealed by the electrical resistivity imaging, which may be the potential route of leachate toward the deep ground. The geochemical data agree well with geophysical data for deducing possible route of leachate of the site.

  • PDF

옥천대(沃川帶)의 지질(地質) 및 광물자원(鑛物資原)에 관(關)한 연구(硏究) -봉화재 지역(地域)에 대(對)한 전기비저항탐사(電氣比抵抗探査)- (Electrical Resistivity Survey on the Geolgical Structure of the Bonghwajae Area in the Okchon Zone)

  • 민경덕;김창렬;윤춘성;정승환
    • 자원환경지질
    • /
    • 제21권2호
    • /
    • pp.131-137
    • /
    • 1988
  • Geological and electrical resistivity surveys were carried out to investigate subsurface geology and geologic structure of the Bonghwajae area in the Okchon zone. Pseudosections of the apparent electrical resistivity distribution along the three survey lines were obtained by using dipole-dipole electrode array method, and models of subsurface geology and geologic structure by using two dimensional finite difference method. The Bonghwajae fault zone exists around Bonghwajae area in the north-south direction, and is a boundary between Okchon Group and Choson Supper Group. Metabasite and hornblende gabbro intruded along the Bonghwajae fault zone remaining two fracture zones with low resistivity value of 20 ohm-m and widths of about 100m and 70-300m. They strike nearly N-S and dip westward with a high angle of $60-70^{\circ}$. Sochangri fault with a width of about 160m exists between Jisogori and Bonghwajae, by which Bonghwajae fault zone is displaced about 1km in the east-west direction. Hornblende gabbro whose electrical resistivity value is in the range of 5000-8000 ohm-m intruded the metabasite of 2000-4500 ohm-m after the Sochangri fault had formed. Great Limestone Group is widely distributed in the east of Bonghwajae fault zone, and interbeds so called Yongam formation of graphitic black slate with an extremely low electrical resistivity value of 2 ohm-m.

  • PDF

전기장 또는 자기장 송신원을 이용한 벡터 CSMT (Controlled Source Magnetotellurics with Vector Measurement Using Electric and Magnetic Sources)

  • 이희순;송윤호
    • 자원환경지질
    • /
    • 제30권5호
    • /
    • pp.451-458
    • /
    • 1997
  • The horizontal magnetic dipole as well as electrical dipole was adopted as a source to compute one-dimensional electromagnetic field behavior in controlled source magnetotellurics. he Cagniard impedances due to horizontal magnetic dipole source, especially phases, showed better frequency characteristics than those due to electric one. The magnetic dipole is inferior to the electric dipole in the point of relatively weak transmitting power at low frequency. But considering high resistivity charateristics of Korean geology, the magnetic dipole source is recommended for the survey up to depth of 500 m. A vector CSMT was introduced to get more reliable data in the area of two- or three-dimensional structures. A software and interpretation technique using polarization ellipses were developed. The technique was tested by synthetic data, which provided theoretical basis of the methodology. Although CSMT has inevitable limitation of investigation depth due to practically possible source-receiver separation, we proposed to use the technique developed in this paper where MT is not available, for example, in extremely noisy area or for shallow target.

  • PDF

전기비저항 탐사를 이용한 충주 무릉매립장 침출수 분포에 관한 연구 (A Study on the Leachate Distribution of the Mooreung Landfill Site with Electrical Resistivity Surveys)

  • 김준경
    • 지질공학
    • /
    • 제16권4호
    • /
    • pp.455-463
    • /
    • 2006
  • 충주시에 위치하고 있는 무릉 생활폐기물 매립장에 쌍극자 배열을 이용한 전기비저항 탐사를 수행하여 폐기물 매립장 내부와 주변지역에 대해 침출수 존재 여부와 존재할 경우 하류지역으로 유출경로를 분석하고자 하였다. 매립장 내부의 전기비저항 분포특성을 고려할 때 매립 후 시간이 경과하여 매립물질로부터 유도된 침출수가 측선 곳곳에서 하부 지반의 공극으로 스며들고 있는 것으로 분석된다. 또한 3개 측선 모두 공통적으로 단면도 왼쪽 지역에 고립된 이상대가 존재하고 이상대의 위치, 발달형태와 전기비저항 절대값 등을 종합적으로 고려할 때 상류, 중류 및 하류 지역에서 각각 발달된 전기비저항 이상대가 상호 연결 가능성이 대단히 높은 것으로 분석된다. 마지막으로 매립장 출입구 부근에 설치된 측선에 대한 전기비저항 탐사결과는 매립장 일부 구간에서 매립장 외부로 침출수가 유출했을 가능성이 대단히 크고 보다 정확한 유출경로 및 심도 등을 분석하기 위해 향후 다른 방법의 지구물리탐사 및 지구화학적방법을 이용하여 보다 많은 탐사가 필요한 것으로 판단된다.

염수침입 현상의 전기비저항 분석에 대한 지구통계기법의 응용

  • 심병완;정상용;김병우
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2001년도 추계학술발표회
    • /
    • pp.92-96
    • /
    • 2001
  • Although the problem of seawater intrusion at the coastal aquifer was recognized before over one hundred years at the coastal aquifer, much groundwater keep on being salinitized by several reasons such as groundwater exhaustion, coastalline change, and human activities. The horizontal and vertical electrical soundings and geostatistical methods were used to define the local characteristics of saltwater intrusion and to estimate the saltwater interface in the southeastern area of the Pusan City. The 24 points of the Schlumberger vertical electrical soundings(VES) to loom depth and the 2 lines of dipole-dipole horizontal soundings are peformed. The resistivity data have lognormal distributions. The horizontal extents of saline water intrusion were estimated from the inversion of horizontal prospecting data. Lognormal ordinary kriging is used in A-A' resistivity profiles on May and July because the data have stationary models in semivariograms. Lognormal IRF-k kriging is used for the isopleth maps using vertical resistivity data. The 10 ohm-m resistivity line on the isopleth maps of 21m, 30m, 50m, and 70m depth using resisitivity data measured in July is sifted to the east, cpomparing that of the isopleth maps measured in May. The kriged vertical and horizontal resistivity isopleth maps suggested that the geostatistical methods can be used to define the variation of earth resistivity distribution at the saltwater interface.

  • PDF

쌍극자-쌍극자 전기비저항 탐사에서 나타나는 음의 겉보기 비저항 (Negative apparent resistivity in dipole-dipole electrical surveys)

  • 정현기;민동주;이효선;오석훈;정호준
    • 지구물리와물리탐사
    • /
    • 제12권1호
    • /
    • pp.33-40
    • /
    • 2009
  • 쌍극자-쌍극자 전기비저항 탐사를 수행하여 자료를 얻다 보면 종종 음의 겉보기 비저항값을 얻게 된다. 음의 겉보기 비저항이란 겉보기비저항 가단면도 상에서 주변자료와 반대되는 부호를 갖고 나타나는 비저항을 의미한다. 이러한 음의 겉보기 비저항은 보통 측정오차로 간주되어 현장 자료 해석시 무시되어 왔다. 일부 측정기기에서는 겉보기 비저항의 절대간이 기록되므로 이러한 음의 비저항값들이 주변값과 같은 부호를 갖는 것으로 환산되어 해석되기도 한다. 현장에서의 여러 실험 결과 옴의 겉보기 비저항갈은 측정오차나 자연전위의 영향에 의해 나타나는 현상이 아니었으며, 유도분극에 의한 영향도 아니었다. 한가지 가능성으로 지하 지질구조에 의한 영향으로 생각할 수 있다. 이 연구에서는 수치모델링을 통하여 평탄한 지형에서 음의 비저항이 지하 지질구조에 의하여 나타날 수 있다는 것을 보여준다. 현장자료를 시뮬레이션하기 위하여 3차원 전산모델링 알고리즘을 이용하였으며, 3차원 결과로부터 2차원 가단면도를 얻었다. 음의 비저항을 발생시키는 모델로는 U자형과 초승달모양의 전도체 모델을 가정하였다. 수치모델링 결과 이러한 지질구조로부터 음의 비저항이 나타날 수 있다는 것을 확인할 수 있었다. 일반적으로 전류전극으로부터의 거리가 멀어질수록 전위값이 증가하게 되면 전위차 곡선들이 서로 교차하면서 음의 비저항값이 나타나는데, 본 연구에서 제시된 결과들에 대해 전극위치에 대한 전위차 그래프를 그려봄으로써 이를 확인할 수 있었다. 본 연구에서 제시한 수치예제들은 현장조사에서 획득한 음의 겉보기 비저항값들이 지하 지질구조에 의해 발생할 수 있는 가능성을 제시하며, 향후 현장조사 자료 해석시 이를 고려하여 해석할 것을 제안한다.

국내 맥상광체조사를 위한 3차원 전기비저항 모델링자료의 3차원 역산 해석 (3-D Inversion of 3-D Synthetic DC Resistivity Data for Vein-type Ore Deposits)

  • 이호용;정현기;정우돈;곽나은;이효선;민동주
    • 한국지구과학회지
    • /
    • 제30권6호
    • /
    • pp.699-708
    • /
    • 2009
  • 최근 들어 국내 광산개발에 대한 관심이 고조되면서 새로운 광상탐사 및 기존 광상의 연장성 확인 등의 목적으로 물리탐사를 적용하는 사례가 늘고 있다. 금속광상 탐사의 경우, 광화대가 주변에 비해 높은 전기전도도를 갖기 때문에 이를 탐지하기 위하여 전기비저항 탐사를 수행하는 것이 일반적이며, 현실 여건상 대부분 2차원 탐사가 수행된다. 그러나 국내 금속광상의 대부분이 맥상으로 분포하고 있으며, 광맥의 폭이 변한다거나 광맥이 단층에 의해 끊어져 있는 등 매우 복잡한 3차원 구조를 띤다. 따라서 3차원 광체구조에 대하여 2차원 탐사 및 2차원 해석을 수행할 경우 왜곡된 해석을 초래할 수 있다. 이에 이 연구에서는 이러한 3차원 광체구조에 대한 3차원 전기비저항 탐사의 적용성을 검토하기 위해 주향에 수직한 여러 측선에 대하여 2차원 쌍극자-쌍극자 탐사를 수행하여 얻은 자료와 3차원 단극자-단극자 배열을 이용하여 얻은 자료들을 각각 3차원 역산한 후 이들을 2차원 해석결과와 비교하였다. 3차원 맥상광체로는 맥폭이 변하는 모형과 맥이 단층에 의해 어긋난 모형 등을 가정하였다. 2차원 쌍극자-쌍극자 배열자료에 대해 3차원 역산을 수행하여 얻은 결과를 3차원 단극자-단극자 배열자료와 비교하면 단극자-단극자 탐사자료가 전체적인 구조는 잘 보여주나 배열의 특성상 쌍극자-쌍극자 탐사자료만큼 정확한 결과를 제시하지 못함을 확인할 수 있었다. 따라서 실제 탐사시 주향의 방향에 대한 정보를 알 수 있다면 주향에 수직한 2차원 측선들에 대해 쌍극자-쌍극자 탐사를 수행하고 이를 3차원 해석하는 것이 가장 바람직하다. 그러나 지표면에 광체가 드러나 있는 경우에 대해서는 이미 개발이 완료된 상태이며, 현재 남아있는 광상은 지하 깊은 곳에 매몰되어 있는 경우가 대부분이다. 이러한 경우 주향에 대한 정보를 알기 어려우므로 비록 해상도는 떨어지더라도 3차원 단극자-단극자 탐사를 수행하고 해석하는 것이 바람직할 것으로 보인다.

종합적 물리탐사에 의한 파쇄대 및 심부 지하수 탐사 (Frture mapping and deep-seated ground water exploration in the crystalline rocks by integrated geophysical techniques)

  • 정승환;김정호;조인기;전정수
    • 지질공학
    • /
    • 제2권2호
    • /
    • pp.113-130
    • /
    • 1992
  • 지하 심부에 발달된 파쇄대 및 단층등은 지하수의 유통통로가 되어 심부 지하수 개발과 직접적인 관련이 있다. 그러므로 지표에서 지하 파쇄대 및 단층을 탐지함은 심부 지하수 개발 대책 수립에 대단히 중요하다. 본 연구에서는 이와 같은 문제에 대한 물리탐사법의 확립을 위해 경주 보문 관관단지내에서 다수의 물리탐사법을 동원하여 종합적인 탐사를 실시 그 자료를 해석하였다. 경주지역은 자력탐사, VLF 전자탐사, 쌍극자 배열 전기탐사, CSAMT 탐사등이 실시되었다. 자려탐사의 목적은 관입암으로 추정되는 화성암의 분포상황의 파악에 VLF 전자탐사는 지표천부의 파쇄대의 탐지에 있다. 쌍극자 배열 전기탐사는 비교적 천부으 비저항 분포 및 단층 파쇄대의 탐지에 CSAMT 탐사는 비교적 심부까지의 비저항 분포 및 단층 파쇄층 탐지에 있다. 경주지역 탐사자료의 종합적인 해석 결과 자력탐사에 의해 퇴적암 하부에 발달하는 화강암의 분포상황을 파악할 수 있었으며, VLF 탐사로써 지표천부의 다수의 파쇄대를 확인하였다. 자력탐사와 전기탐사 그리고 전기탐사의 종합적인 해석에 의해 거의 남북 방향으로 달리는 구조선 및 비저항 분포 상태를 파악할 수 있었으며 이에 의하여 시추가 추천되었다.

  • PDF

물리탐사자료의 GIS 복합처리에 의한 천부지질구조 해석 (Interpretation of shallow geological structure by applying GIS to geophysical data)

  • 송성호;정형재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.123-126
    • /
    • 1998
  • We have conducted surface electrical resistivity surveys along with the electrical logging at Bookil-Myun, Chungwon-Goon, Choongchungbuk-Do to determine the depths of basement and water table, and for the purpose of preparing the basic input data for hydrogeologic model combined with GIS. A twenty lines of dipole-dipole array survey and a twenty-five stations of resistivity sounding were performed and ten holes were employed for electrical logging to cross check the surface data. A combined interpretation gave the quantitative information of the shallow geologic structure over the area and we constructed layers using the grid analysis of Arc/info. The constructed layers were turned out to be similar to the geologic structure confirmed from the drilling data and we concluded that the methodology adopted in this study would be applicable to hydrogeologic model setup as a tool of providing the basic input data.

  • PDF

포항 옥명 폐기물 매립장에서의 전기탐사 (Electrical surveys at the Okmyung waste landfill of Pohang)

  • 이기화;윤종렬
    • 지구물리
    • /
    • 제1권1호
    • /
    • pp.41-50
    • /
    • 1998
  • 포항 옥명 폐기물 매립장과 매립장 입구 전방지역에서 1997년 8월과 1998년 1월에 걸쳐 슐럼버져 전기비저항 수직탐사, 쌍극자 비저항탐사 및 전자기 유도방식을 이용한 전기전도도 수평탐사를 실시하였다. 전기비저항 수직탐사는 매립장 내부와 매립장 입구 전방지역에서 11점과 4점이 실시되었으며, 쌍극자 비저항탐사도 각각 1측선씩 실시되었다. 또한 전기전도도 수평탐사는 총 164점이 4개의 측선을 따라 매립장 입구 전방지역에서 수행되었다. 자료의 해석결과 제 6매립장에서는 0.3∼3 Ωm의 저비저항대가 지표하 65 m까지 나타나고 있어 하부지층의 침출수에 의한 오염가능성을 시사하고 있으며, 예상 침출수위는 지표하 3∼6 m로 추정되었다. 제 9매립장은 2 Ωm이하의 저비저항대가 지표하 11∼15 m까지 나타나고 있어 하부지층의 오염가능성은 없는 것으로 판단된다. 한편 매립장 입구 전방지역에서는 비저항 탐사자료나 전기전도도 수평탐사 자료 모두 천부의 비저항값이 낮게 나타나 이 지역에서는 풍화대의 오염가능성이 매우 큰 것으로 생각된다. 또한 같은 지역내에서도 제 6매립장이 가까이 위치하는 남쪽지역이 침출수의 영향을 더욱 많이 받는 것으로 나타났다.

  • PDF