• Title/Summary/Keyword: electrical interconnection

Search Result 428, Processing Time 0.026 seconds

Electrical Interconnection with a Smart ACA Composed of Fluxing Polymer and Solder Powder

  • Eom, Yong-Sung;Jang, Keon-Soo;Moon, Jong-Tae;Nam, Jae-Do
    • ETRI Journal
    • /
    • v.32 no.3
    • /
    • pp.414-421
    • /
    • 2010
  • The interconnection mechanisms of a smart anisotropic conductive adhesive (ACA) during processing have been characterized. For an understanding of chemorheological mechanisms between the fluxing polymer and solder powder, a thermal analysis as well as solder wetting and coalescence experiments were conducted. The compatibility between the viscosity of the fluxing polymer and melting temperature of solder was characterized to optimize the processing cycle. A fluxing agent was also used to remove the oxide layer performed on the surface of the solder. Based on these chemorheological phenomena of the fluxing polymer and solder, an optimum polymer system and its processing cycle were designed for high performance and reliability in an electrical interconnection system. In the present research, a bonding mechanism of the smart ACA with a polymer spacer ball to control the gap between both substrates is newly proposed and investigated. The solder powder was used as a conductive material instead of polymer-based spherical conductive particles in a conventional anisotropic conductive film.

An effective parallel optical interconnection using single GRIN rod lens (하나의 GRIN Rod Lens를 이용한 효율적 병렬 광연결)

  • Kim, Sung-Chul;Lee, Wook;Lee, Byoung-Ho;Jeong, Ji-Chai
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.1
    • /
    • pp.49-54
    • /
    • 1997
  • We proved the feasibiltiy of a parallel optical interconnection technique using single GRIN (graded-index) rod lens as an intermediate coupling device, which increases the working distance and makes packaging easy. The proposed technique shows relatively less dependency on misalignments. In this paper, for convensience of experiments, we applied this method to 4-channel coupling between two fiber arrays, and compared it with butt-coupling and the method of using ball lens. The comparison shows the feasibility of adopting the proposed method to the parallel interconnection between a laser diode array and an optical fiber array.

  • PDF

A Study on The Electrical Characteristics in Ribbon by Temperature Changes (온도 변화에 따른 Ribbon의 전기적 특성에 관한 연구)

  • Woo, Sung-Cheol;Jung, Tae-Hee;Kim, Tae-Bum;Kang, Ki-Hwan;Ahn, Hyeung-Ken;Han, Deuk-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.67-67
    • /
    • 2010
  • PV module has many power loss factor in the site. Among them, one thing is series resistance. Especially interconnection ribbon resistance is one of the power loss. In this paper, we study interconnection ribbon resistance of the PV module material. In the field, high temperature can pile ribbon resistance on the PV modules. We can do better choice in the optimum use of ribbon through checking relation of ribbon dimension and resistivity. From this point of view, different solder type and dimension was treated.

  • PDF

A Study on Wafer-Level Package of RF MEMS Devices Using Dry Film Resist (Dry Film Resist를 이용한 RF MEMS 소자의 기판단위 실장에 대한 연구)

  • Kang, Sung-Chan;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.379-380
    • /
    • 2008
  • This paper presents a wafer-level package using a Dry Film Resist(DFR) for RF MEMS devices. Vertical interconnection is made through the hole formed on the glass cap. Bonding using the DFR has not only less effects on the surface roughness but also low process temperature. We used DFR as adhesive polymer and made the vertical interconnection through Au electroplating. Therefore, we developed a wafer-level package that is able to be used in RF MEMS devices and vertical interconnection.

  • PDF

LASER MICROWELDING FOR ELECTRICAL INTERCONNECTION IN BIOMEDICAL TECHNOLOGY (의료용 전기 접점부의 마이크로 레이저 용접)

  • ;B.K. Paul;J. Boogaard
    • Proceedings of the KWS Conference
    • /
    • 2003.11a
    • /
    • pp.45-48
    • /
    • 2003
  • Over the past few decades, there has been increasing research and commercial activity in invasive and non-invasive biomedical technology. One important challenge to developing these devices involves the increasing density of electrical interconnects. Resistance spot welding is limited in the density of interconnect based on either the size of welding head or the positional precision with which a weld can be made. Development of an automated laser microwelding system would permit the continued advancement of these important biomedical technologies. The objective of this work is to demonstrate the application of pseudo-pulse Nd:YAG laser technology as an alternative to resistance spot welding in performing electrical interconnection within biomedical products. To date, some experiments have been conducted by using a pseudo-pulse 1064 nm Nd:YAG laser, a successful weld of a 25 ${\mu}{\textrm}{m}$ diameter Pt/Ir wire to a 316 stainless steel shim can be made. Another application involves welding clips, which may be used for external interconnection, to electrodeposited nickel domes that make particular interconnections to specific insulated wires within a cable. These results show a great deal of promise for developing such a process.

  • PDF

An Improved Anti-Islanding Algorithm for Utility Interconnection of Multiple Distributed Fuel Cell Powered Generations

  • Jeraputra Chuttchaval;Hwang In-Ho;Choi Se-Wan;Aeloiza Eddy C.;Enjeti Prasad N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.2
    • /
    • pp.192-199
    • /
    • 2006
  • This paper presents an improved anti-islanding algorithm for utility interconnection of multiple distributed fuel cell powered generations (DFPGs). A cross-correlation method is proposed and implemented in conjunction with the anti-islanding algorithm developed in the previous work [I]. While the power control algorithm continuously perturbs $({\pm}5%)$ the reactive power supplied by the DFPG, the proposed algorithm calculates the cross-correlation index of a rate of change of the frequency deviation with respect to $({\pm}5%)$ the reactive power to confirm islanding. If this index is above 50%, the algorithm further initiates $({\pm}10%)$ the reactive power perturbation and continues to calculate the correlation index. If the index exceeds 80%, the occurrence of islanding can be confirmed. The proposed method is robust and capable of detecting the occurrence of islanding in the presence of several DFPGs, which are independently operating. Viability of the cross-correlation method is verified by the simulation. Experimental results are presented to support the findings of the proposed method.

Environmental Analysis and Evaluation on Fuel Mix by Electric Power System Interconnection in Northeast Asia (동북아 전력계통 연계로 인한 환경성 분석 및 국내 전원구성에의 영향 평가)

  • Chung, Koo-Hyung;Kim, Hong-Geun;Kim, Bal-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.769-771
    • /
    • 2005
  • Interconnection of electric power systems, as an alternative for energy cooperation under regional economic bloc, has been under extensive debate before progressing the restructure in electric power industry and rapidly expanded in many regions after 1990s. Especially, since northeast asia has strong supplementation in resource, load shape, fuel mix etc., electric power system interconnection in this region may bring considerable economic benefits. In this paper, we evaluate economic benefits from CO2 emission abatement and effectiveness on the fuel mix in Korea by the interconnection in northeast asia. For this analysis, we evaluate effects of CO2 emission abatement under various system interconnection scenarios and compare the results of fuel mix in Korean electric power system with and without transacted electricity via interstate electric power system in northeast asia.

  • PDF

Dynamic change of frequency after a generator outage in an Interconnection considering the primary control (연계계통에서 발전기 정지에 따른 주파수의 동적 변화)

  • Stanojevic, Vladimir;Moon, Y.H.;Yoon, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.95-99
    • /
    • 2001
  • Frequency is the unique physical value for all the interconnected systems. Therefore. the load frequency control is in the responsibility of all members in the interconnection power unbalance in one of the interconnected system can cause the problems in others. In the following text a brief description and the role of frequency in an interconnected system will be presented. Following is the short description of the Balkan Interconnection (UCTE Second Synchronous Zone) with schematic diagram. A Power-Frequency (P-f) dynamic model of a control area wil1 be shown. Model gives the analytical solution for frequency change versus a time after outage of a generator in the power system. This model will be applied to the Balkan Interconnection and compared with numerical approach. Advantages and drawbacks of the analytical method will be discussed Purpose of using this model is to investigate if the pumps in reversible hydropower plant will be underfrequency shed after the outage of the biggest generator unit in the interconnection, according %o (n-1) security postulate.

  • PDF

The Influence of Changing PV Array Interconnections under a Non-uniform Irradiance

  • Ding, Kun;Feng, Li;Qin, Si-Yu;Mao, Jing;Zhang, Jing-Wei;Wang, Xiang;Peng, Tao;Zhai, Quan-Xin
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.631-642
    • /
    • 2016
  • Usually, the output characteristics of a photovoltaic (PV) array are significantly affected by non-uniform irradiance which is caused by ambient obstacles, clouds, orientations, tilts, etc. Some local maximum power points (LMPP) in the current-voltage (I-V) curves of a PV array can result in power losses of the array. However, the output power at the global maximum power point (GMPP) is different in different interconnection schemes in a PV array. Therefore, based on the theoretical analysis and mathematical derivation of different topological structures of a PV array, this paper investigated the output characteristics of dual series PV arrays with different interconnections. The proposed mathematical models were also validated by experimental results. Finally, this paper also concluded that in terms of performance, the total cross tied (TCT) interconnection was not always the optimal structure, especially in a dual series PV array. When one of the PV modules was severely mismatched, the TCT worked worse than the series parallel (SP) structure. This research can provide guidance for switching the interconnection to gain the greatest energy yield in a changeable- structure PV system.

Development of Interconnection Protective Relay (연계선로 보호계전기 개발)

  • Park, K.W.;Ahn, H.S.;Shin, J.H.;Park, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.311-313
    • /
    • 2003
  • There have been public attraction and studies about distributed generation systems. But protective relay must be installed between utility system and customer owned distributed generation system has not been developed. So this paper describes the development of a digital protective relay for interconnection. The developed protective relay includes protective elements required by KEPCO at the interconnection point.

  • PDF