• Title/Summary/Keyword: electrical connections

Search Result 187, Processing Time 0.027 seconds

Modeling of Belt-Pulley and Flexible Coupling Effects on Submarine Driven System Electrical Motors

  • Jafarboland, Mehrdad;Zadehbagheri, Mahmoud
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.319-326
    • /
    • 2011
  • Nowadays numerous research projects are being conducted in the field of electric motors. Non-modeling of flexible connections such as couplings and the belt-pulley do not show some real behaviors. With an increase in the number of connections and drive factors, these Non-modeled modes become more important. The coupling of two electric motors, instead of one motor, in submarine propeller force is an obvious example which shows that Non-modeled vibration modes caused by flexible connections can disturb controller operation and make undesirable vibrations in the submarine body. In this paper a dynamic model of flexible connections and a completed dynamic model of two different coupled electric models is presented. A robust controller for the completed model is also amended so that the two controlling targets of a desired speed adjustment and an appropriate load division between the two motors with sufficient accuracy are achieved.

Lifetime-Temperature Rise Model for the Evaluation of Degradation in Electric Connections/Contacts (전기적 접속/접촉부 열화 평가를 위한 수명 온도상승 모델)

  • Kim, Jeong-Tae;Kim, Nam-Jun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.2
    • /
    • pp.55-61
    • /
    • 2002
  • In this paper, 'lifetime-temperature rise model' based on the 'lifetime-resistance model' is theoretically Proposed, in order to find out the evaluation method of degradation and the residual lifetime by use of infrared image camera for electric connections/contacts. Two assumptions have been builded up for the 'lifetime-temperature rise model': one is associated with the linear relationship between the temperature ism ΔK and contact resistance, and the other the functional relationship between the temperature of electric connections/contacts and the operating time presenting in the 'lifetime-resistance model'. To prove the proposed model, experiments have been performed for various electric connections/contacts. From the experimental results, measured values were quite similar to the calculated values, which proved the above-mentioned two assumptions. Therefore, by use of 'lifetime-temperature rise model', it is possible to estimate the trend of degradation and the residual lifetime for electric connections/contacts through the temperature measurements .

Quench Characteristics of Superconducting Elements using Reactors at Series and Parallel Connections (직·병렬연결시 리액터를 이용한 초전도 소자의 퀜치 특성)

  • Choi, Hyo-Sang;Lim, Sung-Hun;Cho, Yong-Sun;Nam, Gueng-Hyun;Lee, Na-young;Park, Hyoung-Min
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.863-869
    • /
    • 2005
  • We investigated quench characteristics of superconducting elements connected in series and parallel each other. The serial and parallel connections of superconducting elements causes a difficulty in simultaneous quench due to slight difference between their critical current densities. In other to induce simultaneous quench, we fabricated four type circuits; serially connected circuit before parallel connection, the circuit connected in parallel before serial connection, serially connected circuit before parallel connection with reactors, the circuit connected in Parallel before serial connection with reactors. We confirmed that the simultaneous quenches occurred in serial and parallel connections of superconducting elements using reactors. In addition, the power burden of superconducting elements was smaller than those of serial and parallel connections of superconducting elements without reactors.

Analysis of Voltage, Current and Temperature Signals for Poor Connections at Electrical Connector (커넥터에서 접촉불량 발생시의 전압, 전류 및 온도 신호 특성 분석)

  • Kim, Sang-Chul;Kim, Doo Hyun;Kang, Shin Uk
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.12-17
    • /
    • 2014
  • This paper is aimed to analyze the characteristics of simultaneous voltage, current and temperature signals for poor connection on electrical connector. In order to attain this purpose, detected were the current and voltage signals on electric wire with series arc, named arc signals, and also monitored were the changes of RMS, instantaneous value of waveform in time domain and temperature value with video. Two states are made normal state over $5kgf{\cdot}cm$ and poor connections state below $0.5kgf{\cdot}cm$ by screw gage. In the voltage signal case, the voltage drop was increased with which the current was increased. In the current signal case, poor connections at the time interval 1~4A all showed "shoulder", as distinct difference from the normal state shown waveform pattern. In the temperature signal case, poor connections are twice at 1A and five times at 4A in the normal state. The temperature continues insulation of electrical wiring and connector can be carbonized. The results of this study will be effectively used in developing the preventive devices and system for electric fire by poor connections.

Circuital Characteristics of Ideal Three-phase Transformer Connections (이상적인 3상 변압기 결선의 회로 특성)

  • Park, In-Gyu
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.9-12
    • /
    • 2008
  • Mathematical singularities of circuit equations with three-phase ideal transformer connections are studied. Three-wired wye-wye connections, delta-delta connections, and primary four-wired wye-delta connections are singular. The matrices of their circuit equations have zeros in their eigenvalues. Three-wired wye-delta connections, wye-wye-delta connections, and primary four-wired wye-wye connections are not singular. The physical meaning of their singularities is that they are sensitive and prone to be ill-conditioned. Equivalent shunt admittances representing ion losses and magnetizing inductances make the singular matrices non-singular in wye-connected circuits. And, equivalent series impedances representing copper losses and leakage inductances make the singular matrices non-singular in delta-connected circuits. The tableau analysis is used for the study.

  • PDF

Design of an Improved On-line Neural Network with Circulating Layer Connections (순환하는 레이어 연결을 갖는 개선된 On-line 신경회로망의 설계)

  • Yeo, Seong-Won;Lee, Chong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2293-2295
    • /
    • 1998
  • In this paper, an improved on-line neural network model is suggested. This neural network is designed to store and recall sequence of key strokes in on-line. The network stores incoming patterns as weight connections between series of layers. The layer has a 2-dimensionally distributed neurons where the location of neurons are relevant to the actual location of computer keyboard. To store longer patterns, the network has circulating layer connections and different patterns can be superposed on the same layer. Also, when the patterns are stored over the layers, the starting layer is not fixed but changed by the characteristics of Patterns to increases network capability. The ways how to choose the starting layer during the store and recall process are investigated.

  • PDF

Air-gap Control According to Y and Delta Connections of Double-sided Air-gap Permanent Magnet Synchronous Motor with Independent Three-phase Structure (독립 3상 구조를 갖는 이중공극형 영구자석 동기전동기의 Y 및 Delta 결선에 따른 공극제어)

  • Heo, Chan-Nyeong;Hwang, Seon-Hwan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.3
    • /
    • pp.249-255
    • /
    • 2017
  • This paper presents air-gap control according to Y and Delta connections of a double-sided air-gap permanent magnet synchronous motor (DA-PMSM) with independent three-phase structure. In particular, the DA-PMSM used in this study can be applied to low-speed and high-torque applications, such as wind turbines, tidal power generations, and electric propulsion ships, because of its modular stators and a rotor with numerous permanent magnets. Unlike conventional three-phase machines, the DA-PMSM has a symmetrical configuration with double-sided air-gap. Therefore, Y/Delta winding connections and serial/parallel configurations between stator modules are possible. To identify the DA-PMSM operating characteristics, mathematical modeling is analyzed according to the Y/Delta connections. Moreover, air-gap control performances by applying the winding connection methods are verified through experimental results.

A Study on the Over Current Relay Misoperation in Power System with Distributed Generations (분산전원 연계 계통에서의 과전류계전기 오동작에 관한 연구)

  • Park, Jong-Il;Lee, Kyebyung;Park, Chang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1705-1710
    • /
    • 2018
  • This paper deals with an analysis of the causes of over current relay(OCR) misoperation in power system with distributed generations(DG). In general, Y-D and Y-Y-D transformer connections are used for grid interconnection of DG. According to the interconnection guideline, the neutral point on Y side should be grounded. However, these transformer connections can lead to OCR misoperation as well as over current ground relay(OCGR) misoperation. Several researches have addressed the OCGR misoperation due to the interaction between transformer connections and zero-sequence voltage of distribution system. Recently, a misoperation of OCR at the point of DG interconnection to the utility system has been also reported. With increasing the interconnections of DG, such OCR as well as OCGR misoperations are expected to increase. In this paper, PSCAD/EMTDC modeling including DG interconnection transformer was performed and various case studies was carried out for identifying the cause of OCR misoperation.

Modeling and Simulation of Master-driven TDD Wireless Communication Systems

  • Lee, Tae-Jin
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2001.10a
    • /
    • pp.459-463
    • /
    • 2001
  • We model and simulate master-driven TDD wireless communication systems, e.g., Bluetooth systems. We model the Bluetooth system and use the BONeS simulation tool to conduct event-drivers simulations. In order to support more than seven slave devices in a piconet, a park mode is considered and modeled. We evaluate the performance, i.e., throughput and delay, using simulations when multi-connections (bath ACL and SCO connections) are present in a piconet. We show that the data rate of ACL connections may be less than 20 kbps when SCO connection(s) and more than six ACL connections are jointly supported in a piconet. In addition, if up to five ACL connections are supported, the average delay is shown to be maintained less than 20 msec. Our results can serve as a guideline to the design of master-driven TDD wireless communication systems with performance requirements.

  • PDF

A Modular System of the Propagation Neural Networks For Reconstruction of Lost Information (소실 정보의 복원을 위한 전송신경망 모듈라 시스템)

  • Kim, Jong-Man;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Hyun-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.119-123
    • /
    • 2002
  • A new modular Lateral Information Propagation Networks(LIPN) has been designed. The LIPN has shown to be useful for reconstruction of information[3]. The problem is the fact that only the small number of nodes can be implemented in a IC chip with the circuit VLSI technology. The proposed modular architecture is propagated the neural network through inter module connections. For such inter module connections, the host (computer or logic) mediates the exchange of information among modules. Also border nodes in each module have capacitors for temporarily retaining the information from outer modules. The LIPN with $4{\times}4$ modules has been designed and simulation of interpolation with the designed LIPN has been done.

  • PDF