• 제목/요약/키워드: electrical connection

검색결과 1,132건 처리시간 0.029초

감극 결선시 자속구속형 전류제한기의 퀜치 특성 (Quench Characteristics of Flux-lock Type SFCL in Subtractive Polarity Winding)

  • 황종선;한태희;최효상;박형민;조용선;남궁현;이나영;임성훈;정동철;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.251-252
    • /
    • 2006
  • As one of methods to increase the voltage rating of the flux-lock type SFCL, the fault current limiting characteristics of the flux-lock type SFCL with HTSC elements connected in series were analyzed. The initial fault current amplitudes in two SFCLs with the series connection of two HTSC elements and with single HTSC element were the same. In addition, the resistance amplitude of each HTSC element in SFCL with the series connection of two HTSC elements had the similar one in SFCL with single HTSC element. With increase of applying voltage, the unbalance of voltage between two HTSC elements in SFCL with the series connection of two HTSC elements disappeared.

  • PDF

계통연계형 인버터의 모델링 및 시뮬레이션 (Modelling and simulation of the grid-interactive inverter)

  • 안교상;임희천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.1345-1347
    • /
    • 2002
  • This paper describes the computer simulation results of the photovoltaic(PV) power system for the grid-connection. The major contents of this paper consist of the modeling of the PV power system for grid-connection, the analysis of the steady-state characteristics of the system, and the analysis of the transient-state characteristics of the system, respectively.

  • PDF

다원 트래픽의 호손율 계산 (Calculation of Blocking Probabilities in the Multi-slot Connection Traffic)

  • 김승환;성단근;김대영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.958-961
    • /
    • 1987
  • Four computational algorithms are discussed and compared which calculate the blocking probabilities in the multi-slot connection traffic for the wide-band services. The computational complexity and time can be significantly reduced, and the overflow and underflow problem can be circumvented as well, by a newly proposed algorithm, the last one.

  • PDF

철도급전시스템 사고발생시 대지전위상승 억제 대책 (Analysis of Rail Potential on the AC Electric Railway Grounding System)

  • 창상훈;오광해;허범;김정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1263-1265
    • /
    • 2001
  • This study presents accurate simulation to examine a reason rail potential rise and how to design ground connection(Cross Connection Cable, CCC) and draw up a plan of an optimal buried grounding system according to section.

  • PDF

도매경쟁전력시장하에서의 AGC 운용체계에 대한 고찰 (A Consideration on the AGC Operation under the Wholesale Market)

  • 권순만;천종민;전동훈;신중선;이효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 2002
  • In this paper a technical consideration is made on the AGC operation under the wholesale market in Korea in view of the signal connection between EMS and power plants for AGC. We review the market rules related AGC operation first. Then we investigate the current AGC connection to measure the level of the satisfaction for the every term in the rules.

  • PDF

풍력발전시스템의 연계변압기 결선방법과 배전계통의 고장전류와의 관계 (Relationship with breakdown electric current of connection transformer connection method and distribution system of wind power generation system)

  • 안해준;노경수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1193-1194
    • /
    • 2006
  • 전력계통에 적용하기 위한 풍력발전시스템의 연계변압기 결선방법과 배전계통의 고장전류와의 관계를 알아보고 계통에서의 단상 고장전류 발생 시 변압기 결선 방식의 변화에 따른 simulation을 수행하고자 한다.

  • PDF

이동용 발전기의 접지방식에 관한 연구 (A Study on the Scheme of Ground Connection for the Mobile Generator)

  • 조규덕;김봉태;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.81-84
    • /
    • 2001
  • In industrial field, especially the mobile generator is almost used as a islanding generator source for light, electric thrill, and compressor, and so on. However, because there still exists a lot of aged load, it causes the electric shock against person. In this paper authors introduce the proper method to reduce the electric shock in field discussing the scheme of ground connection.

  • PDF

Advanced Field Weakening Control for Squirrel-Cage Induction Motor in Wide Range of DC-Link Voltage Conditions

  • Son, Yung-Deug;Jung, Jun-Hyung;Kim, Jang-Mok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.665-673
    • /
    • 2017
  • This paper proposes a field weakening control method for operating an induction motor with a variable DC input voltage condition. In the variable DC voltage condition such as a battery, the field weakening method are required for the maximum output power. The conventional field weakening control methods can be used for operating the induction motor over the rated speed in a constant DC-link voltage condition. However, the conventional methods for operating the motor with the variable DC voltage is not suitable for the maximum output power. To overcome this problem, this paper proposes the optimized field weakening control method to extend the operating range of the induction motor with a rated power in a limited thermal and a wide DC input voltage conditions. The optimized d-axis and q-axis current equations are derived according to the field weakening region I and II to extend the operating region. The experimental results are presented to verify the effectiveness of the proposed method.

규소강판을 이용한 실드케이스의 차폐효과 (A Study on Shield Effect of Shield Case using SiFe Sheet)

  • 신동규;김영학
    • 조명전기설비학회논문지
    • /
    • 제28권2호
    • /
    • pp.48-53
    • /
    • 2014
  • The shield effect of 4 layered shield case was investigated in this paper. The material of the case was non-oriented SiFe sheet with a thickness of 0.5mm. The size of the case was 100mm wide, 100mm high and 300mm long. Relative permeability of SiFe sheet was needed to calculate shield effect. It was obtained from the measurement by a ferrite yoke and from the calculation by eddy current FEM analysis. Three configurations were used to connect both ends of SiFe sheet. First one is a connection by double-welded butt. Second one is to put the sheet the same material above the confronted both ends of the sheet to avoid a leakage magnetic flux. The last one is ideally without any connection. The shield effect of the second one agreed well with the last one and showed the shield effect of -40dB.

Non-Isolated High Gain Bidirectional Modular DC-DC Converter with Unipolar and Bipolar Structure for DC Networks Interconnections

  • Sun, Lejia;Zhuo, Fang;Wang, Feng;Yi, Hao
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1357-1368
    • /
    • 2018
  • In this paper, a novel high gain bidirectional modular dc-dc converter (BMC) with unipolar and bipolar structures for dc network interconnections is proposed. When compared with traditional dc grid-connecting converters, the proposed converter can achieve a high voltage gain with a simple modular transformerless structure. A sub-modular structure for the BMC is proposed to eliminate the unbalanced current stress between the different power units (levels) in the BMC. This can realize current sharing and standardized production and assembling. In addition, phase-interval operation is introduced to the sub-modules to realize low voltage and current ripple in both sides of the converter. Furthermore, two types of bipolar topologies of the sub-modular BMC were proposed to extend its application in bipolar dc network connections. In addition, the control system was optimized for grid-connection applications by providing various control strategies. Finally, simulations of a 3-level unipolar sub-modular BMC and a 4-level bipolar sub-modular BMC were conducted, and a 1-kW experimental 3-level unipolar prototype was developed to verify the effectiveness of the proposed converter.