• 제목/요약/키워드: electric power transmission network

검색결과 131건 처리시간 0.027초

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.

TETRA 무선 기간망에서 SDS(Short Data Service)트래픽에 따른 성능 평가 (The Performance Test Effected by SDS Traffic in TETRA Network)

  • 송병권;황규빈;정태의;김건웅;김진철;김영억
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.376-378
    • /
    • 2008
  • This paper covers that modem performance test is effected by traffic and analysis of the result in TETRA network. The SDS is a method of the between PEIs transmission. And only SDS message type-4 is used to test. The range of the SDS message data length is from 10 to 140 bytes with an increment of 10 bytes. For each length transmitted 1000 times for each delay of inter-transmissions 0.5 second, 1.0 second and 1.5 second. The modem used in the test is the Unimo MU-1000MD by UNIMO Corp.

  • PDF

신경회로망을 이용한 On-line 과도안정도 평가에 의한 자동재폐로 무전압 시간제어 연구 (A Study on the Auto-Reclose Dead lime Control using Neural Network based On-line Transient Stability Assessment)

  • 김일동;박종근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.131-136
    • /
    • 1995
  • This paper presents a functional ability improvement of auto-reclosing relay in the power transmission line protection. When the high speed auto-reclosing is successful, Auto-reclosing is practically valuable to improve the transient stability limit of a power system, but it is fail due to surviving fault, both electrical and mechanical stresses can result on the transformers and turbine-generator. It is true that the longer dead time of the reclosing relay gives the higher rate of successful reclosing, On the other hand, the power system does not always need high speed reclosing because of enough stability margin. This paper proposed "stability margin based dead time reclosing" in order to decrease not only the rate of unsuccessful reclosing, but the possibility of the harmful stress also. On-line transient stability assessment using artificial neural network, for implementing the proposed scheme, has studied and tested with resonable results.

  • PDF

Design of an Algorithm for the Validation of SCL in Digital Substations

  • Jang, B.T.;Alidu, A.;Kim, N.D.
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.89-97
    • /
    • 2017
  • The substation is a critical node in the power network where power is transformed in the power generation, transmission and distribution system. The IEC 61850 is a global standard which proposes efficient substation automation by defining interoperable communication and data modelling techniques. In order to achieve this level of interoperability and automation, the IEC 61850 (Part 6) defines System Configuration description Language (SCL). The SCL is an XML based file format for defining the abstract model of primary and secondary substation equipment, communications systems and also the relationship between them. It enables the interoperable exchange of data during substation engineering by standardizing the description of applications at different stages of the engineering process. To achieve the seamless interoperability, multi-vendor devices are required to adhere completely to the IEC 61850. This paper proposes an efficient algorithm required for verifying the interoperability of multi-vendor devices by checking the adherence of the SCL file to specifications of the standard. Our proposed SCL validation algorithm consists of schema validation and other functionalities including information model validation using UML data model, the Vendor Defined Extension model validation, the User Defined Rule validation and the IED Engineering Table (IET) consistency validation. It also integrates the standard UCAIUG (Utility Communication Architecture International Users Group) Procedure validation for quality assurance testing. Our proposed algorithm is not only flexible and efficient in terms of ensuring interoperable functionality of tested devices, it is also convenient for use by system integrators and test engineers.

한국전력 송전계통 보호 데어터베이스 구축 (A Development of Power Transmission System Protection Database for Korea Electric Power Company)

  • 안영태;이승재;최면성;강상희;김호표;이운희;최홍석
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권7호
    • /
    • pp.847-854
    • /
    • 1999
  • The setting of protective relays, which is critical to the power system security and reliability, requires a huge volume of data processing and repetitive calculation. Since it has been performed by relay engineers manually, it is vulnerable to human errors, its computerization has been pursued, in which the efficient management of the data is the key to the success. The database for power system protection must accommodate not only the power system network data but also a variety of protective devices. Also its information should be able to be viewed and updated with easy by operators and by computer programs. This paper describes several existing database designs for power system protection, their advantages and disadvantages. Also this paper has identified the required function and designed the database for the KEPCO power system data structure for the benefit of the relay setting process, etc..

  • PDF

An Improved Zone-Based Routing Protocol for Heterogeneous Wireless Sensor Networks

  • Zhao, Liquan;Chen, Nan
    • Journal of Information Processing Systems
    • /
    • 제13권3호
    • /
    • pp.500-517
    • /
    • 2017
  • In this paper, an improved zone-based routing protocol for heterogeneous wireless sensor networks is proposed. The proposed protocol has fixed the sized zone according to the distance from the base station and used a dynamic clustering technique for advanced nodes to select a cluster head with maximum residual energy to transmit the data. In addition, we select an optimal route with minimum energy consumption for normal nodes and conserve energy by state transition throughout data transmission. Simulation results indicated that the proposed protocol performed better than the other algorithm by reducing energy consumption and providing a longer network lifetime and better throughput of data packets.

하이브리드 연료전지 자동차의 CAN기반 실시간 시뮬레이터 구현 (Implementation of a CAN Based Real-Time Simulator for FCHEV)

  • 심성용;이남수;안현식;김도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.410-413
    • /
    • 2004
  • In this paper, a simulator system for Fuel Cell Hybrid Electric Vehicles(FCHEV) is implemented using DSP boards with CAN bus. The subsystems of a FCHEV i.e., the fuel cell system, the battery system, the vehicle dynamics with the transmission mechanism are coded into 3 DSP boards. The power distribution control algorithm and battery SOC control are also coded into a DSP board. The real-time monitoring program is also developed to examine the control performance of power control and SOC control algorithms.

  • PDF

GIS 내 금속입자의 부상전압과 부분방전특성 연구 (Lift-Off Voltage and Partial Discharge Characteristics of Free Conducting Particles in GIS)

  • 윤진열;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1684-1686
    • /
    • 1998
  • Gas Insulated Switchgear(GIS) acts as an indispensible part in power transmission network. In order that GIS may have its high reliability, it is necessary to pay careful attention to its whole process e.g., designing, manufacturing, installation, and operation. The main hazard in GIS comes from free conducting particles, which can move and cause breakdown under the influence of the electric field. Although the concentration on protecting the GIS inner part against the free conducting particles is made, it is, actually, almost impossible to avoid the hazard from the particles throughly. In this paper, using the EHV test chamber, partial discharge quantity in GIS was measured when free conducting particles initiate to discharge for providing fundamental data for the purpose of developing predictive diagnosis technology on site GIS.

  • PDF

변전설비 간 상호작용을 고려한 지진응답해석 (Seismic Analysis of Substation Facilities Considering Interaction Effect)

  • 장정범;황경민;서용표;이근직
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.605-612
    • /
    • 2006
  • 765kV substation facilities are most important as electric power supply network in the 21 century. So, in order to prevent interruption of electric power supply under earthquake, 765kV substation facilities have to secure the safety against the earthquake. However, even though each substation facility is interconnected mutually, seismic interaction effect doesn't be considered in the initial design. Therefore, seismic capacity evaluation of 765kV substation facilities is carried out considering the seismic interaction effect on a basis of seismic design criteria for Korean transmission and substation facilities.

  • PDF

Advanced Droop Control Scheme in Multi-terminal DC Transmission Systems

  • Che, Yanbo;Zhou, Jinhuan;Li, Wenxun;Zhu, Jiebei;Hong, Chao
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1060-1068
    • /
    • 2018
  • Droop control schemes have been widely employed in the control strategies for Multi-Terminal Direct Current (MTDC) system for its high reliability. Under the conventional DC voltage-active power droop control, the droop slope applies a proportional relationship between DC voltage error and active power error for power sharing. Due to the existence of DC network impedance and renewable resource fluctuation, there is inevitably a DC voltage deviation from the droop characteristic, which in turn results in inaccurate control of converter's power. To tackle this issue, a piecewise droop control with DC voltage dead band or active power dead band is implemented into controller design. Besides, an advanced droop control scheme with versatile function is proposed, which enables the converter to regulate DC voltage and AC voltage, control active and reactive power, get participated into frequency control, and feed passive network. The effectiveness of the proposed control method has been verified by simulation results.