• Title/Summary/Keyword: electric potential method

Search Result 413, Processing Time 0.027 seconds

A New Gate Pulse Generating Method of 12-Pulse Phase Controlled Rectifier for HVDC (HVDC용 12-펄스 위상제어정류기의 새로운 게이트 펄스 발생 기법)

  • Ahn, Jong-Bo;Kim, Kook-Hun;Lee, Jong-Moo;Lee, Ki-Do
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.139-141
    • /
    • 2000
  • High voltage direct current(HVDC) transmission system uses the phase controlled rectifier triggered by means of IPC(individual phase control) or EPC(equidistant pulse control). Most HVDC system has adopted EPC method that can solve the harmonic instability problem of IPC method in weak power system. But EPC has inherent indirect synchronizing problem requiring the closed loop control. This paper presents the new gate pulse generating method for 12-pulse HVDC converter, which combines IPC with EPC. Simulation and test results are presented. The basic concept is that it generates the gating pulse for 12-pulse converter by synthesizing the internal phase reference using the frequency and phase information of a sin91e phase voltage. To ensure the reliability of the external phase input, Potential transformer that detects the phase voltage has redundancy. Using fault detecting algorithm the healthy input is always guaranteed. And the frequency compensation function was reinforced.

  • PDF

Bending and free vibration analysis of laminated piezoelectric composite plates

  • Zhang, Pengchong;Qi, Chengzhi;Fang, Hongyuan;Sun, Xu
    • Structural Engineering and Mechanics
    • /
    • v.75 no.6
    • /
    • pp.747-769
    • /
    • 2020
  • This paper provides a semi-analytical approach to investigate the variations of 3D displacement components, electric potential, stresses, electric displacements and transverse vibration frequencies in laminated piezoelectric composite plates based on the scaled boundary finite element method (SBFEM) and the precise integration algorithm (PIA). The proposed approach can analyze the static and dynamic responses of multilayered piezoelectric plates with any number of laminae, various geometrical shapes, boundary conditions, thickness-to-length ratios and stacking sequences. Only a longitudinal surface of the plate is discretized into 2D elements, which helps to improve the computational efficiency. Comparing with plate theories and other numerical methods, only three displacement components and the electric potential are set as the basic unknown variables and can be represented analytically through the transverse direction. The whole derivation is built upon the three dimensional key equations of elasticity for the piezoelectric materials and no assumptions on the plate kinematics have been taken. By virtue of the equilibrium equations, the constitutive relations and the introduced set of scaled boundary coordinates, three-dimensional governing partial differential equations are converted into the second order ordinary differential matrix equation. Furthermore, aided by the introduced internal nodal force, a first order ordinary differential equation is obtained with its general solution in the form of a matrix exponent. To further improve the accuracy of the matrix exponent in the SBFEM, the PIA is employed to make sure any desired accuracy of the mechanical and electric variables. By virtue of the kinetic energy technique, the global mass matrix of the composite plates constituted by piezoelectric laminae is constructed for the first time based on the SBFEM. Finally, comparisons with the exact solutions and available results are made to confirm the accuracy and effectiveness of the developed methodology. What's more, the effect of boundary conditions, thickness-to-length ratios and stacking sequences of laminae on the distributions of natural frequencies, mechanical and electric fields in laminated piezoelectric composite plates is evaluated.

Inter-Rater Reliability of the Deep Tendon Reflex by using EMG Electric Reflex Hammer (근전도 전자 망치를 이용한 깊은힘줄반사의 측정자 간 신뢰도)

  • Lee, Jeong-Woo;Seo, Tae-Hwa
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.4
    • /
    • pp.137-143
    • /
    • 2022
  • Purpose : The purpose of this study was to evaluate the reliability analysis of the deep tendon reflex by using electromyography (EMG). Methods : The study was tested on 30 volunteers who are women in their 20s. Using an electronic reflective hammer of EMG, deep tendon reflex was measured on all subjects with the participation of three trained physical therapists as raters. First, the subjects were comfortably seated on a table with their knees bent at 90 °. The three raters tapped the electric hammer at intervals of 10 seconds to avoid habituation until a total of 10 compound muscle action potential records were collected. Intraclass correlation coefficients (ICCs) were calculated to assess the inter-rater reliability of the deep tendon reflex with the use of EMG. The items of analysis included amplitude (mV), latency (ms), duration (ms), and area (mV × ms) of the compound evoked potentials. Results : Based on the average records of 10 compound muscle action potential, excellent reliability (ICC: .912) was achieved in terms of area, and there was good reliability in terms of latency (ICC: .795) and duration (ICC: .800). In the shortest latency of the compound muscle action potential, good reliability was achieved in terms of amplitude (ICC: .865), duration (ICC: .781), and area (ICC: .832). In the amplitude of peak-to-peak of compound muscle action potential, excellent reliability was recorded in terms of amplitude (ICC: .924), and good reliability was recorded in terms of duration (ICC: .801) and area (ICC: .874). Conclusion : The findings in this study indicate that electromyography via an electric hammer is a reliable method of assessing and measuring deep tendon reflexes. Especially, it may be an excellent gauge in the area of average values of the compound muscle action potentials and the amplitude of peak-to-peak of compound muscle action potentials.

Laser Diagnostic in a Plasma Display Panel Discharge Cell

  • Choi, Young-Wook
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2000.01a
    • /
    • pp.21-22
    • /
    • 2000
  • Laser diagnostic method in a plasma display discharge cell was introduced. The information of electric field, potential and electron temperature et al. in the surface of plasma display panel can be measured using laser induced fluorescence spectroscopy. However, because of the very small discharge dimension of ${\sim}$ 100 ${\mu}m$, the measurement attempt has almost not been performed. In this paper, the direct measurement possibility of the parameters and the recent work of electric field measurement are demonstrated in the plasma display panel.

  • PDF

alysis by C-1 Finite Element Method (C-1 유한 요소법에 의한 자계해석에 관한 연구)

  • 임달호;김생수;김규탁
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.1
    • /
    • pp.18-24
    • /
    • 1988
  • Up to date, C-0 Finite Element Method which is the means for analyzing electric machinery can not be got the precision magnetic flux density because the magnetic flus density has the discontinuity in the interelement. To supplement this defect, we propose the C-1 finite element method of 9 D.O.F. in this paper. In this method, the vector potential and the magnetic flux density are continuous on the interelement and direction derivative of potential would be an unknown value. We developed the algorithm to apply this method. For examining the utility, we applied this method to analytic model and compared with the result of C-0 Finite Element Method using linear element.

  • PDF

Study on the effect of DC voltage in oil-immersed transformer insulation system (DC 전압이 유입변압기 절연시스템에 미치는 영향에 관한 연구)

  • Jang, Hyo-Jae;Kim, Yong-Han;Seok, Bok-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1552-1553
    • /
    • 2011
  • The HVDC transformer which is one of the main equipments for HVDC(High Voltage Direct Current) electric power transmission systems is exposed to not only AC voltage but also the inflowing DC voltage which comes from the DC-AC converter systems. Therefore, the HVDC transformer insulation system is required to withstand the electric field stress under AC, DC and DC polarity reversal conditions. However the electric field distributions under those conditions are different because the AC electric field and DC electric field are governed by permittivity and conductivity, respectively. In this study, the changes of electric potential and electric field of conventional AC transformer insulation system under DC polarity reversal test condition were analyzed by FEM(Finite Element Method). The DC electric field stress was concentrated in the solid insulators while the AC electric field stress was concentrated in the mineral oil. In addition, the electric stress under that condition which is affected by the surface charge accumulation at the interfaces between insulators was evaluated. The stress in some parts could be higher than that of AC and DC condition, during polarity reversal test. The result of this study would be helpful for the HVDC transformer insulation system design.

  • PDF

Computational analysis of hemodynamics in a human ventricular model (인간 심실모델에서의 혈류역학 해석)

  • Shim, Eun-Bo;Kwon, Soon-Sung;Kim, Yoo-Seok;Jung, Hyung-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2947-2950
    • /
    • 2007
  • A 3D human ventricular model is proposed to simulate an integrative analysis of heart physiology and blood hemodynamics. This consists of the models of electrophysiology of human cells, electric wave propagation of tissue, heart solid mechanics, and 3D blood hemodynamics. The 3D geometry of human heart is discretized to a finite element mesh for the simulation of electric wave propagation and mechanics of heart. In cellular level, excitations by action potential are simulated using the existing human model. Then the contraction mechanics of a whole cell is incorporated to the excitation model. The excitation propagation to ventricular cells are transiently computed in the 3D cardiac tissue using a mono-domain method of electric wave propagation in cardiac tissue. Blood hemodynamics in heart is also considered and incorporated with muscle contraction. We use a PISO type finite element method to simulate the blood hemodynmaics in the human ventricular model.

  • PDF

EMTDC Modeling Method of DC Reactor type Superconducting Fault Current Limiter

  • Lee, Jaedeuk;Park, Minwon;Yu, In-Keun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.56-59
    • /
    • 2003
  • As electric power systems grow to supply the increasing electric power demand short-circuit current tends to increase and impose a severe burden on circuit breakers and power system apparatuses. Thus, all electric equipment in a power system has to he designed to withstand the mechanical and thermal stresses of potential short-circuit currents. Among current limiting devices, Fault Current Limiter (FCL) is expected to reduce the short-circuit current. Especially, Superconducting Fault Current Limiters (SFCL) offer ideal performance: in normal operation the SFCL is in its superconducting state and has negligible impedance, in the event of a fault, the transition into the normal conducting state passively limits the current. The SFCL using high-temperature superconductors offers a positive resolution to controlling fault-current levels on utility distribution and transmission networks. This study contributes to the EMTDC based modeling and simulation method of DC Reactor type SFCL. Single and three phase faults in the utility system with DC reactor type SFCLs have been simulated using EMTDC in order to coordinate with other equipments, and the results are discussed in detail.

Characterization of Emulsion Properties for D-limonene (D-리모넨 오일의 유화특성)

  • 하윤식;장윤호;문현수;이정경;서무룡
    • Journal of Environmental Science International
    • /
    • v.7 no.6
    • /
    • pp.875-881
    • /
    • 1998
  • Microemulsion is prepared by the method of phase inversion emulsification with d-limonene that is environmental friendly substance and nontoxic to human body as dispersed phase. Emulsifier used for preparation of microemulsion is nonionic surfactants, polyoxyethylene nonylphenyl ether. Stability of prepared microemulsion was estimated by the various method of ξ-potential, hydrodynamic diameter and electric conductivity. When d-limonene is emulsified by NP series, microemulsion is most stable and narrowly distributed at HLB value of 12.3(either one emulsifier or mixed emulsifiers). Stability of microemulsion is increased as the amount of emulsifiers is increased at same HLB value of 12.3. In the case of using the same amount of emulsifiers, number of produced micelle are relatively large as hydrodynamic diameter is small. Therefore, the state of microemulsion is stable and the electric conductivity is increased. One can determine that higher electric conductivity value means that microemulsion has more micelles and is more stable.

  • PDF

Investigation on electromagnetothermoelastic interaction of functionally graded piezoelectric hollow spheres

  • Dai, Hong-Liang;Rao, Yan-Ni
    • Structural Engineering and Mechanics
    • /
    • v.40 no.1
    • /
    • pp.49-64
    • /
    • 2011
  • An analytical method is presented to investigate electromagnetothermoelastic behaviors of a hollow sphere composed of functionally graded piezoelectric material (FGPM), placed in a uniform magnetic field, subjected to electric, thermal and mechanical loads. For the case that material properties obey an identical power law in the radial direction of the FGPM hollow sphere, exact solutions for electric displacement, stresses, electric potential and perturbation of magnetic field vector in the FGPM hollow sphere are determined by using the infinitesimal theory of electromagnetothermoelasticity. Some useful discussion and numerical examples are presented to show the significant influence of material inhomogeneity. The aim of this research is to understand the effect of composition on electromagnetothermoelastic stresses and to design optimum FGPM hollow spheres.