• 제목/요약/키워드: electric lens

검색결과 70건 처리시간 0.023초

A Review of Electrically Tunable Focusing Liquid Crystal Lenses

  • Lin, Hung-Chun;Chen, Ming-Syuan;Lin, Yi-Hsin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제12권6호
    • /
    • pp.234-240
    • /
    • 2011
  • Electrically tunable focusing liquid crystal (LC) lenses are reviewed in this paper. The distribution of the orientations of LC directors which is controlled by electric fields results in a distribution of refractive indices of LC directors. The incident light can be modulated by the electrically tunable lens-like phase difference of the LC lens. We introduce the basic operating principles of LC lenses and discuss the structures of LC lenses. The major challenges of LC lenses are also discussed. We believe this paper provides a guideline for basic understanding of LC lenses.

광화이버 및 Fresnel lens 적용 집광식 자연채광 시스템의 이용을 통한 조명에너지의 절감: 시뮬레이션 및 실측 비교 (Electric Lighting Energy Saving Through the Use of A Fresnel Lens Based Fiber-optic Solar Lighting System: Simulation and Measurements)

  • 정해준;김원식;김영민;한현주;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제37권3호
    • /
    • pp.1-12
    • /
    • 2017
  • This paper deals with the effectiveness of a fiber optic solar lighting system that uses a Fresnel lens mounted on a two-axis solar tracker. A series of comparative analyses were made concerning its performance as compared to fluorescent lighting by using a simulation model based on ECOTECT and RADIANCE as well as referring to actual data. ECOTECT was used to model the test room (space) while RADIANCE was used for its indoor lighting conditions (environment). It was found that the average indoor light levels of fluorescent lighting fully satisfy the KS standard (KS A 3011, general office, class [G]: 300-400-600 lux) whereas those of the solar lighting with light diffusers depends on the occlusion factor of roller shades installed on the south window.

자동초점 조절용 VCM 액추에이터 구동특성 분석 (The analysis design and operating characteristics of VCM actuator for auto focusing)

  • 박정민;임홍우;채봉;김대곤;김평호;조금배
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.447-448
    • /
    • 2007
  • Product development is consisting by trend that accommodate almost function digital cam in camera phone that can speak of Mobile appliance, and competition about number of elemental area of image sensor is consisting for market prior occupation between these. Propose in this research and small size camera phone self-focusing adjustment actuator that do city manufacture is similar with general storehouse pickup actuator drive way, but selected in cylindrical to reduce space that lens holder occupies because there is restriction loading of lens and space enemy. Target number of research established that execute drive displacement more than $600{\mu}m$ in 2.75V that is house voltage that is used in Mobile device that is general. Also, described about maximum transfer displacement characteristic, displacement response characteristic, hysteresis, response characteristic, smallest transfer step characteristic, actuator's drive characteristic that is manufactured to examination item of maximum consumption electric power by special quality estimation system that apply laser displacement sensor that produce itself to evaluate city manufactured actuator's special quality.

  • PDF

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

  • Yokoyama, Sumi;Tsujimura, Norio;Hashimoto, Makoto;Yoshitomi, Hiroshi;Kato, Masahiro;Kurosawa, Tadahiro;Tatsuzaki, Hideo;Sekiguchi, Hiroshi;Koguchi, Yasuhiro;Ono, Koji;Akiyoshi, Masahumi;Kunugita, Naoki;Natsuhori, Masahiro;Natsume, Yoshinori;Nabatame, Kuniaki;Kawashima, Tsunenori;Takagi, Shunji;Ohno, Kazuko;Iwai, Satoshi
    • Journal of Radiation Protection and Research
    • /
    • 제47권1호
    • /
    • pp.1-7
    • /
    • 2022
  • Background: In Japan, new regulations that revise the dose limit for the lens of the eye (hereafter the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulation Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set not to exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 examples. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of the guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimize radiation protection.

유한요소법을 사용한 주사전자 현미경의 전자렌즈 설계 및 해석에 관한 연구 (A Study on Design and Analysis for Magnetic Lenses of a Scanning Electron Microscope using Finite Element Method)

  • 박근;정현우;박만진;김동환;장동영
    • 한국정밀공학회지
    • /
    • 제24권9호
    • /
    • pp.95-102
    • /
    • 2007
  • The scanning electron microscope (SEM) is one of the most popular instruments available for the measurement and analysis of the micro/nano structures. It is equipped with an electron optical system that consists of an electron beam source, magnetic lenses, apertures, deflection coils, and a detector. The magnetic lenses playa role in refracting electron beams to obtain a focused spot using the magnetic field driven by an electric current from a coil. A SEM column usually contains two condenser lenses and an objective lens. The condenser lenses generate a magnetic field that forces the electron beams to form crossovers at desired locations. The objective lens then focuses the electron beams on the specimen. The present work concerns finite element analysis for the electron magnetic lenses so as to analyze their magnetic characteristics. To improve the performance of the magnetic lenses, the effect of the excitation current and pole-piece design on the amount of resulting magnetic fields and their peak locations are analyzed through the finite element analysis.

주사 전자현미경의 이미지 해상도 향상을 위한 방안 및 실험적 검증 (Methodologies and Verifications for Enhancing Resolution of a Scanning Electron Microscopy)

  • 김동환;김영대;박만진;장동영;박근
    • 한국공작기계학회논문집
    • /
    • 제16권5호
    • /
    • pp.122-128
    • /
    • 2007
  • The electric part of thermal SEM(Scanning Electron Microscopy) consists of high voltage generation, lens control, and image processing. Several methodologies for enhancing SEM image are addressed and those results are verified through analyses and experiments. The controller employes a DSP(Digital Signal Processing), making the system more flexible and convenient than the classical analogue based controller. In some parts based the analog circuit, there are inevitable sources of noise and image distortion. The experimental investigation is provided along with analytical proof to enhance the SEM image.

케미컬오일을 이용한 ERF 연마 특성 (Characteristics of ERF Polishing using Chemical-oil)

  • 윤종호;이재종;이응숙;이동주;김영호
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.27-33
    • /
    • 2004
  • Electro-theological fluid is recently used for the micro polishing of 3-dimensional micro-aspherical lens. It's also used for polishing small area defects on the wide flat wafer. Since ER fluid shows a behavior of viscosity changing under certain electric fields. micro polishing efficiency may be enhanced for certain cases. In this paper, a perfluorinated carbonyl fluoride oil based ER fluids was used to improve surface polishing rate and submicron-scale accuracy. As the polishing electrodes, micro size cylindrical tools had been used for maximizing the electric field. An experimental device, which was applied for micro polishing a number of wafers of 4inches in size and other workpiece. was made on a precision polishing system. It consisted of a steel electrode. a wafer fixture. l0㎃ current and DC 5㎸ power supply unit, and a controller unit. From the Experiments. the ER fluid is applicable for micro polishing of small parts.

  • PDF

ER유체를 이용한 미세연마의 원리 (The principle of a electrorheological polishing for a small part)

  • 김욱배;이상조
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.968-971
    • /
    • 2002
  • Two decisive mechanisms of the electrorhological polishing for a small part(for example, a aspherical surface in a micro lens) are explained. Firstly, non-uniform electric field generated in the polishing structure increases a shear stress of ER fluids which is maximized dramatically near the tool, therefore, substrate adjacent to the tool can be removed effectively by mixed abrasives in the ER fluid. Secondly, abrasives in a non-uniform electric field are governed by the dielectrophoretic phenomena. Abrasives move toward the tool because the field gradient is highest near the tool and then abrasives are actively holded in that area. This phenomena is observed and evaluated by the optical measurement.

  • PDF