• Title/Summary/Keyword: electric impedance

검색결과 583건 처리시간 0.039초

Looseness Estimation of Bolts on Truss Structure with PZT Patches

  • Jiang, Zhongwei;Akeuchi, Yasutaka
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.86.6-86
    • /
    • 2002
  • This work presents a study on development of a practical and quantitative technique for assessment of the healthy state of a structure by piezoelectric impedance-based technique associated with longitudinal wave propagation measuring method. A truss structure embedded with piezoelectric patches is investigated for a fundamental study on estimation of the looseness of bolts in the joint. In order to evaluate the minute mechanical impedance change due to loosening bolt, a harmonic longitudinal elastic wave is applied to the structure by a pair of PZT patches and their electric impedance is measured simultaneously. According to the experimental results, the change of the electric impedance of P...

  • PDF

TN-C-S 접지계통에서 외부 루프 임피던스의 실측 및 기준값 설정에 관한 연구 (A Study on the Measurement and Determination of External Loop Impedance on TN-C-S System)

  • 이건호;정진수;문현욱;김선구
    • 전기학회논문지
    • /
    • 제62권8호
    • /
    • pp.1163-1168
    • /
    • 2013
  • The maximum allowable value of loop impedance($Z_s$) to secure the operation of overcurrent protective devices and the safety for indirect contact is a very important in TN-C-S system. The loop impedance is divided into inner loop impedance which consumer can adjust and external loop impedance($Z_e$) which only electric operator can adjust. Thus, an external loop impedance which limits to less than a certain value is a very important factor for human body protection against electric shock in TN-C-S system. The concept of loop impedance($Z_s$) is recently introduced to the domestic, the study about external loop impedance is yet insufficient. However, the study about the reference impedance as specified by the IEC 60725 standard to improve the quality and reliability of the power supply is being made. In this paper, reference value of external loop impedance($Z_e$) to meet domestic environment will be proposed by the nationwide measurement and statistical analysis.

구형파를 이용한 전극계면 분석용 고속 임피던스 분석기의 설계변수 확정을 위한 컴퓨터 시뮬레이션 (Computer simulation to determine system parameters of the square-wave adapted fast impedance analyzer for the electrode - electrolyte interface analysis)

  • 김기련;김광년;심윤보;전계록;정동근
    • 한국시뮬레이션학회논문지
    • /
    • 제14권2호
    • /
    • pp.45-55
    • /
    • 2005
  • There are electric double layer capacitance, polarization resistance and solution resistance in the interface between electrode and solution. Electrode process could be evaluated by the electrical impedance analysis. The necessities of the electrochemical cell analysis with high speed impedance analyzer are followings: minimization of the effects of electric stimulation on electrochemical cell and the concentration of reactive materials, and optimization of impedance signal resolution. This paper represents the design criteria for the selection and stimulation to develop fast impedance analyzer prototype for a electrochemical cell. It was suggested that the design of 470k sample/s sampling rate, 13 bit ABC resolution, and 140ms recording time is required for high speed impedance analysis system in frequency range between dc and 10kHz.

  • PDF

전력선통신을 위한 고압 배전선로의 방사전계강도 계산 (Calculation of Radiative Electric Field Intensity of Overhead Medium-Voltage Power lines for Power Line Communication)

  • 천동완;박영진;김관호;신철재
    • 한국통신학회논문지
    • /
    • 제30권12A호
    • /
    • pp.1136-1146
    • /
    • 2005
  • 본 논문에서는 전력선 통신을 위해 사용되는 고압 배전선로에서 통신신호 및 잡음신호에 의해 방사되는 방사전계강도를 계산하였다. 전력선 통신 네트워크의 2포트 등가모델 및 기본적인 전송선로 이론을 이용해 입력임피던스를 계산하였다. 그리고 계산된 입력임피던스를 이용해 전력선상 전류를 계산하고 최종적으로 방사전계강도를 계산하였다. 전력선의 특성임피던스가 매우커서 입력 단에서의 반사가 심하기 때문에 입력임피던스는 일정한 주기를 가지는 정재파 형태를 가진다. 계산된 전류 및 방사전계 또한 이러한 형태임을 알 수 있었다. 실제 측정한 결과계산 치와 측정치가 매우 유사함을 알 수 있었다.

인체 통전전류 위상 분석을 통한 저항성 누설전류 감시의 유효성 분석 (The Effectiveness Analysis of the Resistive Leakage Current Monitoring by Analyzing the Phase of the Body Current)

  • 김재현;임용배;이상익;김동우
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.90-99
    • /
    • 2013
  • To analyze the effectiveness of the resistive leakage current monitoring as a technology preventing electrical accidents, in this paper, we have estimated the phase of the body impedance by using the body impedance model and the body impedance data from IEC. We also have analyzed the phase of the electric body current in the case of 60Hz/220V. From these results, we concluded that deliberate researches about the phase of the electrical body current and related regulations must be carried out before the resistive leakage current monitoring unit is used to protect electric shock. And we concluded that the resistive leakage current monitoring unit can be utilized to prevent electrical fires caused by electric leakage current without unwanted circuit break due to capacitive leakage current flowing from line filter capacitors to the earth.

IEC60479 인체 임피던스 모델에 근거한 직류누설전류의 특성 및 검출 알고리즘 (Detection Algorithm and Characteristics on DC Residual Current based on Analysis of IEC60479 Impedance Model for Human Body)

  • 김용중;이진성;김효성
    • 전력전자학회논문지
    • /
    • 제23권5호
    • /
    • pp.305-312
    • /
    • 2018
  • DC distribution systems has recently taken the spotlight. Concerns over human safety and stability facility are raised in DC distribution systems. Std. IEC 60479 provides basic guidance on "the effects of shock current on human beings and livestock" for use in the establishment of electrical safety requirements and suggests an electrical impedance of the human body. This study analyzes impedance spectrums based on the electrical equivalent impedance circuit for the human body; human body impedances measured by experiments are analyzed below the fundamental frequency (60 Hz). The analysis shows that the equivalent impedance circuit for the human body should be modified at least in low-frequency range below the fundamental frequency (60 Hz). The DC residual current detection method that can classify electric shock accidents of humans and electric leakages of facilities is proposed by applying the analysis result. The detection method is verified by experiments on livestock.

전기철도 급전계통 임피던스 분석장치 개발 (Development of Power System Impedance Analyzer on the Electric Railway)

  • 이장무;창상훈;한문섭;오광해
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.387-389
    • /
    • 1998
  • For the continuous and exact measurement of load impedance of AC power system on the electric railway, this paper presents a method to show the load area to resistance(R)-reactance(X) plane of impedance plane. The load area is presented in terms of impedance which is in the ratio of voltage and current continuously measured and impedance plane indicates the protection area of fault locator. The proposed method is verified its reasonability by computer simulation, and using this method we will develop the power system impedance analyser which is available actual application.

  • PDF

전기역학적 임피던스 기법을 이용한 강섬유 보강 모르타르의 응결시간 평가 (Measurement of Setting Times of Steel Fiber Reinforced Mortar using Electric-mechanical Impedance Sensing Technique)

  • 이준철;김화중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.183-184
    • /
    • 2016
  • This study investigated the evolution of electro-mechanical impedance (EMI) of piezoelectricity (PZT) sensor embedded in hydrating steel fiber reinforced mortar to determine the setting times of that. Penetration resistance test was also conducted in order to justify the valid of EMI sensing technique. As a result, the setting times of steel fiber reinforced mortar can be effectively monitored through the EMI sensing technique using PZT sensor.

  • PDF

뇌격전류에 의한 수평접지극의 전위상승 계산 (Calculation of Electric Potential Rise of Horizontal Grounding Electrode Caused by Lightning Stroke Currents)

  • 이복희;조성철
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.81-86
    • /
    • 2013
  • An electric potential rise of the grounding electrode developed by the lightning stroke currents should be calculated for the purpose of effective protection of electrical and electronic equipment. In this paper, the electromagnetic model was applied to calculate the harmonic impedance of grounding electrode. Also the empirical equation related to the permittivity and resistivity of soil was used. The lightning current waveforms, which are expressed by the Heidler's equation, were used in order to calculate accurately transient electric potential rises. The transient voltage was obtained by using the simulated harmonic impedance and the lightning current in frequency domain. Finally, the transient voltages of horizontal grounding electrode(10m) under lightning stroke currents were calculated by IFFT(Inverse Fast Fourier Transform).

증조류 선로 고장시 인접선로 과부하에 의한 거리계전기 동작 및 전압불안정 현상 연구 (A study of impedance relay operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line)

  • 윤기섭;이형한;김창곤;안보순
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.359-361
    • /
    • 2005
  • This paper presents the method of countermeasures before voltage collapse by load encroachment(impedance of load ability on R-X locus decrease toward zero point) and describes a study of impedance relay(zone-3) operation and voltage instability caused by over load of neighborhood line at contingency of heavy load line.

  • PDF