• 제목/요약/키워드: electric

검색결과 33,503건 처리시간 0.048초

전격재해의 유형 및 대책에 관한 연구 (A Study on Classification of Electric Shock Disasters and Countermeasures)

  • 권영준;손병창;이명희;신승헌
    • 한국안전학회지
    • /
    • 제15권4호
    • /
    • pp.47-55
    • /
    • 2000
  • In this modern age which electric energy is the fundamental source of energy in the industry, electric shock disasters are unavoidable. Although numerous efforts, time, and money have been invested to prevent such electric shock disasters, the number of electric shock disasters are on the increase. In this study, models for equivalent electric circuit are developed for the different types of electric shock which are classified into three groups. The objective of these models is to calculate the electric current flowing through the body at the time of the shock. Based on the analysis, countermeasures to prevent the shock are suggested. The data used in this study are based on 28 actual incidents which occurred in the Daegu area during January of 1995 through June of 1999. The results of this study can be used as a technical manual for workers treating electrical facilities.

  • PDF

경계요소법을 이용한 표면 거침도에 따른 아라미드 절연지의 전계분포 해석 (Analysis of Electric Field Distribution according to Surface Roughness of Aramid Insulating Paper Using Boundary Element Method)

  • 김탁용;안병철;조경순;박형준;홍진웅
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.34-39
    • /
    • 2006
  • In this paper, we investigated the electric field distribution according to the roughness in aramid insulating paper for electric machine. Aramid insulating paper has been used to electric insulating of the traction motor and generators for large capacity. We studied the electric field distribution using boundary element method for Aramid insulating paper. As a result of simulation, the electric field increased according to the surface roughness existence. Electric field decreased due to radius of surface roughness reduction, and Electric field concentration appeared at electrode boundary and rough surface.

Relation between Ramp-reset and Barrier Rib Height in AC PDP cells

  • Lee, Y.J.;Lee, S.K.;Kim, W.J.;Kim, Y.D.;Kim, M.S.;Moon, S.J.;Kwon, Y.H.;Yoo, S.J.;Kim, J.D.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.75-78
    • /
    • 2002
  • Difference in the structure of AC PDP cells makes the cells have various discharge characteristics. Therefore, a ramp-reset must be adjusted for the stable driving of AC PDP. If any ramp-reset can reduce the difference in discharge characteristics between cells, the conditions of the address discharge could become almost the same. It is very important to understand these to design a good driving waveform. In this paper, we proved the mentioned facts with the change of barrier rib heights.

  • PDF

전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구 (Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube)

  • 류승관;원상희;차민석;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제32회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

전기차 충전 인프라와 전력망 간의 통신 상호운용성 연구 (Communication Interoperability of Electric Uehicle Charging Infrastructure and Grid Network)

  • 주승환;이일호;송상훈
    • 디지털산업정보학회논문지
    • /
    • 제14권1호
    • /
    • pp.15-25
    • /
    • 2018
  • ISO/IEC 15118 is a standard for communications and services for electric vehicle charging infrastructure. Although this standard deals only with data communication between an electric vehicle and a charge station, communication with the outside is essential for establishing an authentication system for vehicle certification and V2G service for electric power transmission. In this study, it was designed to verify the information of electric car charging infrastructure in electric power system through communication link between ISO/IEC 15118 electric vehicle model and IEC 61850 standard MMS protocol. This is demonstrated in the field so that the electric vehicle communication data is linked with the micro grid management system. This could be used as an element technology in other distributed power sources as well as electric cars in the future.

송전선로의 전자계 크기 측정 및 분석 (Measurement and Analysis of Electric and Magnetic Fields Near Overhead Transmission Lines)

  • 김상범;조성배;신구용;이동일;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1908-1910
    • /
    • 1997
  • The electric and magnetic fields (EMFs) near 345/154 kV overhead transmission lines were measured. The average values of maximum electric field and magnetic field for 44 transmission lines were 1.11 kV/m and 24.5 mG, respectively. These values were lower than any standards of advanced countries. The EMFs of distribution lines and substation, and electric appliances were also measured and compared with those of transmission lines.

  • PDF

디젤발전 자켓냉각시스템 열성능 향상 연구 (Performance Research of a Jacket Cooling Water System in a Diesel Electric Generation)

  • 이재근;문전수;윤석원;박필양
    • 한국수소및신에너지학회논문집
    • /
    • 제20권6호
    • /
    • pp.534-539
    • /
    • 2009
  • One of the most efficient techniques improving the heat transfer performance of a diesel electric generation is a corrosion control in jacket cooling water system. The environmental parameters most affecting corrosion are dissolved salt concentration, temperature, and pH of cooling water. No corrosion occurs in carbon steel probe at pH 11 in normal operating condition of diesel electric generation cooling water. pH control agent in this study is trisodium phosphate. pH control appears to be the most convenient way to enhance the thermal performance of a diesel electric generation.

Flexible Ultra-high Gas Barrier Substrate for Organic Electronics

  • Yan, Min;Erlat, Ahmet Gun;Zhao, Ri-An;Scherer, Brian;Jones, Cheryl;Smith, David J.;McConnelee, Paul A.;Feist, Thomas;Duggal, Anil
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.445-446
    • /
    • 2007
  • The use of plastic substrates enables new applications, such as flexible display devices, and other flexible electronic devices, using low cost, rollto-roll (R2R) fabrication technologies. One of the limitations of polymeric substrate in these applications is that oxygen and moisture rapidly diffuse through the material and subsequently degrade the electro-optical devices. GE Global Research (GEGR) has developed a plastic substrate technology comprised of a superior high-heat polycarbonate (LEXAN(R)) substrate film and a unique transparent coating package that provides the ultrahigh barrier (UHB) to moisture and oxygen, chemical resistance to solvents used in device fabrications, and a high performance transparent conductor. This article describes the coating solutions for polycarbonate (LEXAN(R)) films and its compatibility with OLED device fabrication processes.

  • PDF

Co-combustion of Bituminous Coal with Anthracite in a Down-firing, 200 MW Boiler

  • Park, Ho Young;Baek, Se Hyun;Kim, Young Joo;Kim, Tae Hyung;Kim, Hyun Hee;Lim, Hyun Soo;Park, Yoon Hwa
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제1권1호
    • /
    • pp.93-97
    • /
    • 2015
  • The combustion tests for Korean anthracite-bituminous coal blend were carried out in the 200 MW utility boiler. The burning characteristics of the blend were studied with a thermogravimetric analyzer (TGA). From the observation of TGA burning profiles, it was found that the presence of bituminous coal in the blend appeared to enhance the reactivity of anthracite in the higher temperature region, indicating certain interactions between the two coals. The plant test showed the boiler operation was reasonably stable with somewhat poor combustion efficiency, and some modification of the combustion environment in the furnace is necessitate for the further stable plant operation.

욕조에서의 전위분포 해석을 통한 전격재해 위험성 평가 (Evaluation on Electric Shock Risk due to the Electric Potential Distribution in Bathtub)

  • 김종민;김한상;김성철;김두현
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.40-46
    • /
    • 2007
  • It is evaluated that electric shock risk in bath so that we made and designed a bathtub which is the same size in real public bath. And then, we did an experiment, provided of electric leakage in various conditions, so we measured how to form an electric potential and knew the electric potential is formed variously under exposed conductor in bath. Also, we made certain that electric shock risk is down if we insert an insulated pipe in bathtub pipe which is prevent from being formed the electric field sharply. The results show that the increased shock risk and safe distance are estimated by the bathtub of limited width and depth, and the voltage simulated on the basis of Flux 3D concept is compared with the measured value.