• Title/Summary/Keyword: effective mass ratio

Search Result 334, Processing Time 0.027 seconds

NEWLY DISCOVERED z ~ 5 QUASARS BASED ON DEEP LEARNING AND BAYESIAN INFORMATION CRITERION

  • Shin, Suhyun;Im, Myungshin;Kim, Yongjung;Jiang, Linhua
    • Journal of The Korean Astronomical Society
    • /
    • v.55 no.4
    • /
    • pp.131-138
    • /
    • 2022
  • We report the discovery of four quasars with M1450 ≳ -25.0 mag at z ~ 5 and supermassive black hole mass measurement for one of the quasars. They were selected as promising high-redshift quasar candidates via deep learning and Bayesian information criterion, which are expected to be effective in discriminating quasars from the late-type stars and high-redshift galaxies. The candidates were observed by the Double Spectrograph on the Palomar 200-inch Hale Telescope. They show clear Lyα breaks at about 7000-8000 Å, indicating they are quasars at 4.7 < z < 5.6. For HSC J233107-001014, we measure the mass of its supermassive black hole (SMBH) using its C IV λ1549 emission line. The SMBH mass and Eddington ratio of the quasar are found to be ~108 M and ~0.6, respectively. This suggests that this quasar possibly harbors a fast growing SMBH near the Eddington limit despite its faintness (LBol < 1046 erg s-1). Our 100% quasar identification rate supports high efficiency of our deep learning and Bayesian information criterion selection method, which can be applied to future surveys to increase high-redshift quasar sample.

Displacement Response Analysis of Twisted Irregular Buildings According to TMD (TMD 적용에 따른 Twisted 비정형 건축물의 변위 응답 분석)

  • Yoo, Sang-Ho;Kim, Hyun-Su;Kang, Joo-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.24 no.1
    • /
    • pp.89-98
    • /
    • 2024
  • In this study, we investigated the dynamic characteristics of three irregular building models to analyze the effectiveness of displacement response control with Tuned Mass Damper (TMD) installation in twisted irregular buildings. The three irregular models were developed with a fixed angle of twist per story at one degree, subjected to three historical seismic loads and resonant harmonic loads. By designing TMDs with linear and dashpot attributes, we varied the total mass ratio of the installed TMDs from 0.00625% to 1.0%, encompassing a total of 10 values. Two TMDs were installed at the center of the top story of the analysis model in both X and Y directions to evaluate displacement response control performance based on TMD installation. Our findings suggest that the top displacement response control performance was most effective when a 1.0% TMD was installed at the top layer of the analysis model.

Characteristics of NOx Emission with Flue Gas Dilution in Air and Fuel Sides

  • Cho, Eun-Seong;Chung, Suk Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.12
    • /
    • pp.2303-2309
    • /
    • 2004
  • Flue gas recirculation (FGR) is a method widely adopted to control NOx in combustion system. The recirculated flue gas decreases flame temperature and reaction rate, resulting in the decrease in thermal NO production. Recently, it has been demonstrated that the recirculated flue gas in fuel stream, that is, the fuel induced recirculation (FIR), could enhance a much improved reduction in NOx per unit mass of recirculated gas, as compared to the conventional FGR in air. In the present study, the effect of FGR/FIR methods on NOx reduction in turbulent swirl flames by using N$_2$ and CO$_2$ as diluent gases to simulate flue gases. Results show that CO$_2$ dilution is more effective in NO reduction because of large temperature drop due to the larger specific heat of CO$_2$ compared to N$_2$ and FIR is more effective to reduce NO emission than FGR when the same recirculation ratio of dilution gas is used.

Effective Element Removal Methods for Topology Optimization (위상 최적화를 위한 효율적인 요소 제거법)

  • 한석영
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.04a
    • /
    • pp.46-51
    • /
    • 2000
  • In case of ESO(evolutionary structural optimization) which is one of topology optimization methods, the element removal ratio is fixed throughout topology optimization by 1 or 2 %. As a result it has no flexibility for various types of structures and thus the rate of convergence might not be efficient. Thus various element removal methods are developed in order to improve the efficiency of ESO. In this paper, various element removal methods for ESO are compared with each other. Each element removal method is explained, and applied to a bracket and a Michell type of beam. In addition, a new bi-directional element removal method is suggested in order to obtain much better optimized topology. From the results of stress, displacement and the rate of convergence for the examples under the same mass constraints, it is verified that the suggested element removal method is the most effective. .

  • PDF

The effect of the number of nozzle holes on the energy separation (보텍스튜브의 노즐홀수가 에너지분리에 미치는 영향)

  • 유갑종;이진호
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.5
    • /
    • pp.692-699
    • /
    • 1999
  • The vortex tube is a sample device for separating a compressed gaseous fluid stream into two flows of high and low temperature without any chemical reactions. The phenomena of energy separation through the vortex tube were investigated experimentally, to see the effects of the number of nozzle holes on the energy separation. The experiment was carried out with the number of nozzle holes from 1 to 10 by varying inlet pressure and cold mass fraction. The experimental results were indicated that the effective number of nozzle holes for the best cooling performance was found as 4. Also, to find effective use in a given operation conditions, the temperature difference of cold air and the cooling capacity of vortex tube was compared. The result is that cooling capacity was more important than temperature difference of cold air.

  • PDF

Equivalent material properties of perforated metamaterials based on relative density concept

  • Barati, Mohammad Reza;Shahverdi, Hossein
    • Steel and Composite Structures
    • /
    • v.44 no.5
    • /
    • pp.685-690
    • /
    • 2022
  • In this paper, the equivalent material properties of cellular metamaterials with different types of perforations have been presented using finite element (FE) simulation of tensile test in Abaqus commercial software. To this end, a Representative Volume Element (RVE) has been considered for each type of cellular metamaterial with regular array of circular, square, oval and rectangular perforations. Furthermore, both straight and perpendicular patterns of oval and rectangular perforations have been studied. By applying Periodic Boundary conditions (PBC) on the RVE, the actual behavior of cellular material under uniaxial tension has been simulated. Finally, the effective Young's modulus, Poisson's ratio and mass density of various metamaterials have been presented as functions of relative density of the RVE

A 8-Week, Randomized, Double-Blind, Placebo-Controlled Human Trial to Evaluate the Efficacy and Safety of Punica granatum L.·Actinidia chinensis Planch. Mixed Extract on Body Fat (석류·참다래 혼합추출물의 체지방 감소에 대한 유효성 및 안전성을 평가하기 위한 8주, 무작위 배정, 이중눈가림, 위약-대조 인체적용시험)

  • Choi, Jin-Bong;Lee, Ji-Eun;Do, Yun-Kyoung
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.17 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • Objectives: This study was conducted to evaluate efficacy and safety of Punica granatum L. Actinidia chinensis Planch. mixed extract on body fat. Methods: Thirty women were recruited ($25kg/m^2{\leq}body$ mass index [BMI]${\leq}29.9kg/m^2$) ($19yr{\leq}age{\leq}38yr$) and randomized to receive Punica granatum L. Actinidia chinensis Planch. mixed extract or placebo for 8 weeks. During the test, they visited four times including screening. Body fat mass, body fat rate, anthropometric dimensions at waist and hip, waist-hip ratio, total cholesterol, triglyceride, low density lipoprotein-cholesterol (LDL-C), and high density lipoprotein-cholesterol (HDL-C) were measured at screening and 8 weeks after screening. Adverse reaction were also checked each visit. Results: There were no significant differences in all index. But when divide experimental group by BMI index, age, and compliance, less than BMI $27kg/m^2$ group decreased body weight, body fat mass and more than BMI $27kg/m^2$ group also decreased body weight, body fat mass and waist circumference. Less than age 30 years group showed decline of waist circumference, fat free rate and T-cholesterol and more than age 30 years group showed decline of fat free mass. Group with compliance more than 95% was decreased BMI, fat free mass, and hip circumference. Conclusions: There was no significant efficacy as compared with placebo group, but as divide experimental group according to BMI index, age, compliance, mixed extract might be effective to reduce obesity index.

The Effects of Ganoderma Lucidum Pharmacopuncture and Moxibustion (Wang-tteum) on Abdominal Obesity: Case Report (영지약침과 왕뜸 복합치료의 복부비만 개선사례: 증례보고)

  • Park, Soo Ah;Lee, Heun Ju;Baek, Ji-Yeong;Son, Kyung-Woo;Lim, Kyeong-Tae
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.16 no.1
    • /
    • pp.64-69
    • /
    • 2016
  • This study was conducted to investigate the effects of Ganoderma lucidum pharmacopuncture and moxibustion on abdominal obesity. Five women with abdominal obesity were treated 6 times in 2 weeks with Ganoderma lucidum pharmacopuncture on abdominal fat followed by 30 minutes of moxibustion on abdominal area. Before treatment and after 6 treatments were finished, body weight, body mass index, body fat mass, waist circumference, hip circumference and waist-hip ratio were measured. After all treatments, all average measured values were reduced. Body weight and body mass index were reduced by 0.34 kg and $0.46kg/m^2$ respectively. Also, waist circumference and waist-hip ratio were reduced by 4.52 cm and 0.04 respectively. We suppose combined therapy of Ganoderma lucidum pharmacopuncture and moxibustion might be a time-effective treatment for abdominal obesity.

Performance evaluation of inerter-based damping devices for structural vibration control of stay cables

  • Huang, Zhiwen;Hua, Xugang;Chen, Zhengqing;Niu, Huawei
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.615-626
    • /
    • 2019
  • Inerter-based damping devices (IBBDs), which consist of inerter, spring and viscous damper, have been extensively investigated in vehicle suspension systems and demonstrated to be more effective than the traditional control devices with spring and viscous damper only. In the present study, the control performance on cable vibration reduction was studied for four different inerter-based damping devices, namely the parallel-connected viscous mass damper (PVMD), series-connected viscous mass damper (SVMD), tuned inerter dampers (TID) and tuned viscous mass damper (TVMD). Firstly the mechanism of the ball screw inerter is introduced. Then the state-space formulation of the cable-TID system is derived as an example for the cable-IBBDs system. Based on the complex modal analysis, single-mode cable vibration control analysis is conducted for PVMD, SVMD, TID and TVMD, and their optimal parameters and the maximum attainable damping ratios of the cable/damper system are obtained for several specified damper locations and modes in combination by the Nelder-Mead simplex algorithm. Lastly, optimal design of PVMD is developed for multi-mode vibration control of cable, and the results of damping ratio analysis are validated through the forced vibration analysis in a case study by numerical simulation. The results show that all the four inerter-based damping devices significantly outperform the viscous damper for single-mode vibration control. In the case of multi-mode vibration control, PVMD can provide more damping to the first four modes of cable than the viscous damper does, and their maximum control forces under resonant frequency of harmonic forced vibration are nearly the same. The results of this study clearly demonstrate the effectiveness and advantages of PVMD in cable vibration control.

A Study on the Treatment of Wastewater from Small-scale dyehouse (소규모 염색공장 폐수의 처리에 관한 연구)

  • 이준현;허항록;김광진;김민영;신재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.23-25
    • /
    • 2002
  • This study was conducted to understand characteristics of wastewater which is discharged from small-scale dyehouse located in Seoul downtown area and to Find the appliable treatment method on the spot. The results of this study were summarized as followings. 1. The method which is used at present is mostly flocculation by coagulant or fenton oxidation. But the treatment efficiency of them are not good. 2. The results of fenton oxidation experiment demonstrated that treatment efficiency of COD was limited, which showed the need of the additional process or the improvement of existing treatment method, while the color was reduced considerably in optimal condition. 3. The optimal condition of fenton oxidation are as followings. -Feasible pH was in the 3∼4 regardless of the kinds of iron ions, But the fluctuation of treatment efficiency with the change of pH was small - The mass ratio of H$_2$O/CODcr was used to evaluate the parameter of H$_2$O$_2$ The optimal range of this was in 0.7∼1,3 and it was observed that the ratio got higher as the quality got worse. -For iron ion, FeCl$_2$4H$_2$O turned out to be more effective for removal of color compared with was compared FeSO$_4$7H$_2$Oin. the mass ratio of Fe/H$_2$O$_2$ of 2.3∼2.8 for of FeSO$_4$7H$_2$O and 1.6∼1.8 for FeCl$_2$4H$_2$O resulted in good treatment efficiencies. 4. With adsorption process applied before fenton oxidation in order to treat the high concentration wastewater, the treatment efficiency increased by 61% in CODcr, 55% in color. and if the power activated carbon is injected in more than 2500mg/$\ell$, the wastewater can be treated within the effluent quality criteria.

  • PDF