• 제목/요약/키워드: ecological concrete

검색결과 169건 처리시간 0.026초

생태하천 복원 방안 (Suggestions for Ecological Stream Restoration)

  • 김명진
    • 환경영향평가
    • /
    • 제16권1호
    • /
    • pp.59-68
    • /
    • 2007
  • Urban streams have been severely degraded with wastewater and concrete structure over a prolonged period. The Chonggyecheon Restoration Project recovered a stream in the downtown Seoul with landscaping, plantings and bridges after the cover concrete and elevated asphalt road were removed. The project has been criticized partly because it is not an ecological restoration but rather the development of an urban park with an unnaturally straight flowing stream, artificial building structures, and artificial water pumping from the Han River. Nevertheless, the public have praised the project and almost 100,000 visitors per day come to see the reeds, catfish, and ducks. The stream restoration project is attractive to central and regional government decision makers because it increases the public concern of landscape amenity. Several projects such as Sanjichon and Kaeumjungchon are on going and proposed. These projects have a common and different respect in scope and procedure. The Chonggyecheon project in the process of environmental impact assessment (EIA) and prior environmental review system (PERS) reviewed the environmental impacts before development. Kaeumjungchon in the PERS and Sanjichon without EIA and PERS are reviewed. EIA and PERS systems contribute to checking the ecological sustainability of the restoration projects. A stream restoration project is a very complex task, so an integrated approach from plan to project is needed for ecologically sound restoration. Ecological stream restoration requires 1) an assessment of the entire stream ecosystem 2) establishing an ecologically sound management system of the stream reflecting not only benefits for people but also flora and fauna; 3) developing the site-specific design criteria and construction techniques including habitat restoration, flood plains conservation, and fluvial management; 4) considering the stream watershed in land use plan, EIA, PERS, and strategic environmental assessment (SEA). Additionally the process needs to develop the methodologies to enhance stakeholder's participation during planning, construction, and monitoring.

기포콘크리트를 이용한 친환경 내화충전제개발에 관한 기초적 연구 (A Fundamental Study on the Development of Fire Resistance Filling of Friendly Environment Using Aerated Concrete)

  • 이종일;임남기
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.119-126
    • /
    • 2007
  • In this study, we processed two procedures of application test of filler for fire-resistance utility that are new application methods of aerated concrete and properties test of aerated concrete according to mixing ratio because we investigated the better use of aerated concrete as filler for fireproof safety and we proposed basic data about standardization of mixing of aerated concrete. We measured flow and volume change of aerated concrete. And if its volume doesn't change, we added measuring unit weight and compressive strength. To test application of aerated concrete as filler for fireproof safety, we filled up aerated concrete to fireproof safety according to suitable mixing ratio. Then we measured maximum temperature of inner part of fireproof safety in accordance with the standard test of fireproof. According to the results, aerated concrete as filler for fireproof safety could be possibly used. So when we make aerated concrete, we should consider using an adding agent as well as a foaming agent.

플라이애시를 함유한 고강도 콘크리트의 조기 강도와 속도 발현 특성 (Characteristics of Early Strength and Velocity Development in High Strength Concrete Containing Fly Ash)

  • 이회근;윤태섭;이광명
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.43-48
    • /
    • 2001
  • The use of fly ash in cement and concrete industries has many benefits including engineering, economic, and ecological aspects. However, it has a disadvantage of low strength development, especially at early ages. In this study, in order to overcome this problem, the early strength accelerating agent($NA_{2}$ $SO_{4}$) was selected and applied to the production of high strength concrete(HSC) containing fly ash. It was found that the compressive strength of fly ash concrete incorporating TEX>$NA_{2}$ $SO_{4}$ has greater than that of concrete containing fly ash only until 7 days after casting. From the microstructural point of view, ettringite increased and pores decreased in fly ash concrete incorporating TEX>$NA_{2}$ $SO_{4}$ , leading to the development of early age strength. It was also found that the velocity vs. strength relationship of HSC is considerably different from that of low-strength concrete(LSC). Therefore, in order to predict early age strength of HSC, a estimation equation different from that for LSC is needed.

  • PDF

굳지않은 포러스콘크리트의 품질관리를 위한 실험적 연구 (An Experimental Study on the Quality Control of Fresh Porous Concrete)

  • 이성일;장종호;김재환;강석표;백용관;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.705-710
    • /
    • 2002
  • Recently, there has been for a number of reasons growing interest in the use of porous concrete, and it is used as an ecological material. But, because the valuation methods of the quality on the fresh porous concrete aren't established up till now, it is difficult that the harden porous concrete is made sure of its required quality. This study is to present the measurement method of the void ratio on the fresh porous concrete and to analyze the influence of water-cement ratio and vibrating time on the binder content covered a coarse aggregate. Results of this study were shown as follows; The measurement methods of the void ratio and aggregate-binder weight ratio on the fresh porous concrete can be useful as data for the quality control of fresh porous concrete.

  • PDF

초고강도 철근콘크리트 띠철근 기둥의 구속효과 (Confined Effect of Ultra High Strength Reinforced Concrete Tied Columns)

  • 한범석;신성우;김태수
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.105-111
    • /
    • 2007
  • As this study investigates the influence about type of transverse reinforcement, spacing of transverse reinforcement(s), volumetric ratios of transverse reinforcement(${\rho}s$) of ultra-high strength concrete columns. It try to offer to resonable basic data of the confined model for the ultra-high concrete of in reinforced concrete columns. Experimental tests with large scaled columns were conducted under concentric axial loads. The ultra-high strength concrete (100MPa) was used. From this test result, it evaluate influence of the strength enhancement and ductility enhancement, important variables about behavior of the confined concrete by confinement of ultra-high strength reinforced concrete.There are two ways to improve the confinement effect of high strength concrete columns through the increase of amounts and/or strength of transverse reinforcement.

샛강 생태복원을 위한 해외 사례 연구의 고찰 (An Analytical Study of Foreign Researches and Examples on Ecological Restoration for the Small Stream)

  • 권태호;박재현;김동욱
    • 한국환경복원기술학회지
    • /
    • 제7권5호
    • /
    • pp.26-37
    • /
    • 2004
  • Most domestic small rivers and streams due to industrialization and urbanization have managed by concrete structures. The environmental functions of the river and stream are disappearing and urban streams play only the role of drainage systems. Also, the researches to restore natural streams are something yet to develop and not established the restoration for ecological functions of a small stream. Therefore the researches are required to develop ecological engineering system for watershed management system to handle various pollutants with restoration for ecological functions of a small stream. To develop this, the ecological engineering system for watershed management system could be developed with ecological conservation. In addition, ecological engineering system for watershed management system should be prior to conserve the habitat of biological resources and water conservation and applied to the original shape of streams. Also, it should be designed to restore the micro-topography of stream, the habitat of plant population in watershed. It is needed to develop the integrated researches to restore a small stream ecosystem.

축하중을 받는 콘크리트 충전 탄소섬유튜브 기둥의 소성 이론을 적용한 비선형 유한요소해석 (Nonlinear finite element analysis of Concrete Filled Carbon Tube Columns Using Plasticity Theory)

  • 김희철;서상훈;이영학
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.119-126
    • /
    • 2007
  • In the field of composite structures, the use of carbon tube for the confinement of concrete has been arisen since 1990's. However, experimental and analytical studies were limited to those of reinforced concrete and concrete filled steel tube. The carbon tube provides excellent confinement capabilities for concrete cores, enhancing compressive strength and ductility of concrete significantly. The carbon tube has high tensile strength, light weight, corrosion immunity and high fatigue strength properties. Since carbon fiber is an anisotropic material, carbon tube could be optimized by adjusting the fiber orientation, thickness and the number of different layers. In this study, both experimental and analytical studies of axial and lateral behavior of full-scale CFCT (Concrete Filled Carbon Tube) columns subjected to monotonic axial load were carried out using Drucker-Prager theory. And, based on comparison results between experiment results and analytical results, k factor estimation was proposed for effective analysis.

콘크리트용 PNS 치환 혼화제의 기초물성 및 친환경 특성 평가에 대한 실험적 연구 (An Experimental Study on the Basic Performance and Eco-Affinity Property of PNS Substituted Additive for Concrete)

  • 김도수;길배수;전준영;전영환;류득현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.729-732
    • /
    • 2008
  • 나프탈렌계 유동화제는 오랫동안 콘크리트 혼화제중 AE감수제의 주요성분으로 우수한 효과 때문에 널리 사용되어 왔으나 포름알데히드의 혼용으로 인해 유해성이 지적되어 왔다.따라서 본 연구에서는 AE 감수제에 사용되는 나프탈렌계 고성능감수제(PNS)에서 합성과정에서 포르말린을 적용하지 않은 PNS 치환용 혼화제를 제조하고, 이를 콘크리트에 적용하여 PNS를 사용한 기존 AE감수제와 콘크리트의 기초물성에 미치는 효과 및 친환경 특성을 평가하였다.

  • PDF

천연 무기 광물계 혼화재료를 혼입한 철근콘크리트 구조물의 부식저항성에 관한 연구 (A Study on Corrosion Resistance of Reinforced Concrete Structures using Natural Inorganic Minerals)

  • 태성호;박재영;김재영;박재승;경제운;남호윤
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.127-133
    • /
    • 2007
  • As a fundamental study on the corrosion resistance of reinforced concrete structures using Natural Inorganic Minerals exposed to carbonation environment, The test specimens were concrete(W/C=60%) with Natural Inorganic Minerals content of 0%, 10%. Accelerated carbonation and autoclave corrosion accelerated curing were then conducted with them. The corrosion resistance of steel in concrete with Natural Inorganic Minerals content of 0%, 10% was examined by corrosion form, half-cell potential, polarization resistance, corrosion area and weight loss after 24 hours of autoclave corrosion accelerated curing.The results of the study showed that as for steel in concrete with Natural Inorganic Minerals content of 10%, the corrosion resistance was more excellent than steel in concrete with Natural Inorganic Minerals content of 0%.

철골 프리캐스트 콘크리트 합성보 성능 분석 연구 (Load carrying capacity of Structural Composite Hybrid System (Green Frame))

  • 홍원기;김선국;김승일
    • KIEAE Journal
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2010
  • An experimental investigation of composite beams composed of wide flange steel and precast concrete is presented. The bottom flange of the steel section is encased in precast concrete. The composite beams tested in this study were designed to reduce the depth of the slab and beam. The slabs are constructed on top of the edges of the Structural Composite Hybrid System, instead of on top of the steel flange, decreasing the depth of the beams. When concrete is cast on the metal deck plate located on the edges of the precast concrete, the weight of the concrete slabs and other construction loads must be supported by the contacts between the steel and the precast concrete. This interface must not exhibit bearing failures, shear failures, and failures caused by torque due to the loading of the precast concrete. When the contact area between the concrete and the bottom flange of the steel beam is small, these failures of the concrete are likely and must be prevented. The premature failure of precast concrete must not also be present when the weight of the concrete slabs and other construction loads is loaded. This paper presents a load carrying capacity of Structural Composite Hybrid System in order to observe the failure mode. The symmetrically distributed loading that caused the failure of the composite beam was found. The paper also provides design recommendations of such type of composite structure.