• Title/Summary/Keyword: echo time

Search Result 454, Processing Time 0.022 seconds

A Comparative Analysis of Basal Body Temperature to Ultrasound, as a Method of Ovulation Detection in Induced Ovulatory Menstrual Cycles (배란유도주기에 따른 초음파검사와 기초체온표의 비교분석)

  • Choi, W.;Suh, B.H.;Lee, J.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.12 no.2
    • /
    • pp.25-37
    • /
    • 1985
  • Four points on the basal body temperature (B.B.T.) curve was correlated with the estimated time of ovulation, as determined by serial ultrasound in 50 induced menstrual cycles from 22 subjects. The time of ovulation was estimated by measuring the maximal diameter of follicles and observing the morphologic changes within the ovary from follicle to corpus luteum. The results were as following; 1. The diameter of the follicle measured at the day before disappearance was 21.1 mm on an average (S.D.: 2.14). The average follicular growth for 4 days before ovulation was measured at a rate of 2.8 mm/day, and rapid growth of follicle was observed 3.1 mm/day at the day before. 2. The changes associated with rupture of the follicles were the followings, in order of frequency; decrease in size(94%), disappearance of follicles(64%), fluid in the Cul-de-Sac(26%) and increased internal echoes(16%). 3. Only 20 of 50 cycles, exhibited a BBT dip and correlated with the estimated time of ovulation by ultrasound in 2 of which cases(10%). BBT nadir, 30 of 50 cycles, correlated in 5(16.7%). The first day of hyperthermic plateau(FDHP) and BBT coverline was exhibited in all cycles, correlated in 41(82%) and 35(70%) cases. 4. The relationship between the diameter of dominant dominant follicle, measured by ultrasound, and the basal body temperature curve were as following. During cycles in which dip was observed on the BBT curve, the follicular diameter were 10.5${\pm}$2.12 mm on 4 days prior to the point (D-4), and 12.5${\pm}$2.12 mm (D-3), 15.5${\pm$2.12 mm (D-2), 17.0${\pm}$1.41 mm (D-1) and 21.5${\pm}$2.12 mm just prior to the dip (D-0). In the nadir; 9.6${\pm}$1.67 mm (N-4), 12.8${\pm}$1.79 mm (N-3), 16.2${\pm}$1.92 mm (N-2), 18.2${\pm}$2.17 mm (N-1) and 21.4${\pm}$2.61 mm (N-0). In the First day of Hyperthemic Plateau (FDHP); 9.8${\pm}$1.36 mm (F-4), 12.4${\pm}$1.41 mm (F-3),15.1${\pm}$1.57 mm (F-2), 18.1${\pm}$1.67 mm (F-1) and 21.2${\pm}$2.25 mm (F-0). In the BBT coverline endopint; 9.9${\pm}$.39 mm (C-4), 12.5 ${\pm}$1.44 mm (C-3), 15.2${\pm}$1.64 mm (C-2), 18.0 ${\pm}$1.69 mm (C-1), and 21.2${\pm}$2.31 mm (C-0). 5. The relationship between the ultrasonographic signs of ovulation and the basal body temperature curve were as following. The BBT dip correlated with the ovulation in 2 cases, which revealed decrease in follicular diameter (100%), fluid pattem in the Cul-de-Sac (1 case, 50%) and complete disappearance of follicle (1 case, 50%). In the nadir (5 cases); the ultrasonographic signs of ovulation were decrease in follicular diameter (5 cases, 100%), fluid pattern in the Cul-de-Sac (1 case, 20%) and complete disappearance of follicle (3 cases, 60%). In the First day of Hyperthermic Plateau (41 cases); decrease in follicular diameter (40 cases, 97.6%), fluid pattern in the Cul-de-Sac (11 cases, 26.8%), appearance of internal echo and thickening of the wall (6 cases, 14.6%) and com plete disappearance of follicle (28 cases, 68.3%). In the BBT coverline endpoint (35 cases); decrease in follicular diameter (33 cases, 94.3%), fluid pattern in the Cul-de Sac (9 cases, 25.7%), appearance of internal echo and thickening of the wall (5 cases 14.3%) and complete disappearance of follicle (20 cases, 57.1%).

  • PDF

Investigation of Varied MR Spectra by TE and Metabolite Amount in the Localized Voxel using the MR Cone-shape Phantom (자기공명분광법에서 TE와 Voxel 내의 대사물질 양에 따른 스펙트럼 변화 평가에 관한 연구)

  • Woo, Dong-Cheol;Kim, Sang-Soo;Rhim, Hyang-Shuk;Jahng, Geon-Ho;Choe, Bo-Young
    • Progress in Medical Physics
    • /
    • v.18 no.3
    • /
    • pp.179-185
    • /
    • 2007
  • The purpose of this study is to investigate the spectra of a magnetic resonance spectroscopy (MRS) in accordance with the variance of TE and the volumes of metabolites in a localized voxel for the quality assurance using a designed single voxel spectroscopy QA phantom. Because a cone-shade phantom is designed as the volume of metabolite in a localized voxel is changeable, we try to analyze the peaks of each metabolite (NAA, Cr, Cho, Lac, etc.) in accordance with metabolite volume in a localized voxel as well as echo time (TE). All data were obtained using a 3T MRI/MRS machine and analyzed using $jMRUI^{(R)}$. The results of this study show that TE is in inverse proportion to the noise of MRS and the longer TE and the less metabolite volume in the localized voxel, the peak intensities of each metabolite decrease. In case of the lactate, its peak was observed on the all TE only if the greatest metabolite is included in the localized voxel. Then, the intensity of a metabolite is more sensitive to the metabolite volume in the localized voxel than the TE. These obtained in vitro MRS data is provide the guideline that is important for in vivo metabolite quantification. But, in the edge of cone-shape vial air bubbles were observed and spectrum could not obtained. Therefore our cone-shape MRS phantom needs to be modified in order to solve these problems.

  • PDF

Delamination Evaluation of Thermal Barrier Coating on Turbine Blade owing to Isothermal Degradation Using Ultrasonic C-scan Image (초음파 C-scan을 이용한 터빈 블레이드 열차폐코팅의 등온열화에 의한 박리 평가 기법)

  • Lee, Ho-Girl;Kim, Hak-Joon;Song, Sung-Jin;Seok, Chang-Sung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.353-362
    • /
    • 2016
  • Thermal barrier coating (TBC) is an essential element consisting of a super-alloy base and ceramic coating designed to achieve long operational time under a high temperature and pressure environment. However, the top coat of TBC can be delaminated at certain temperatures with long operation time. As the delamination of TBC is directly related to the blade damage, the coupling status of the TBC should be assured for reliable operation. Conventional studies of nondestructive evaluation have been made for detecting generation of thermally grown oxide (TGO) or qualitatively evaluating delamination in TBC. In this study, the ultrasonic C-scan method was developed to obtain the damage map inside TBC by estimating the delamination in a quantitative way. All specimens were isothermally degraded at $1,100^{\circ}C$ with different time, having different partial delamination area. To detect partial delamination in TBC, the C-scan was performed by a single transducer using pulse-echo method with normal incidence. Partial delamination coefficients of 1 mm to 6 mm were derived by the proportion of the surface reflection signal and flaw signal which were theoretical signals using Rogers-Van Buren and Kim's equations. Using the partial delamination coefficients, the partial delamination maps were obtained. Regardless of the partial delamination coefficient, partial delamination area was increased when degradation time was increased in TBC. In addition, a decrease in partial delamination area in each TBC specimen was observed when the partial delamination coefficient was increased. From the portion of the partial delamination maps, the criterion for delamination was derived.

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

A Study of NMEA Protocol Multiplexer Simulation on the based optimizing Queue (최적화된 큐 기반의 NMEA 프로토콜 멀티플렉서 시뮬레이션에 관한 연구)

  • Park Si-Hyoung;Jung Sung-Hun;Kim Chang-Soo;Yim Chang-Mook;Yim Jae-Hong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.11a
    • /
    • pp.15-19
    • /
    • 2004
  • Domestic use, or embody program that transmit NMEA protocol using multi port as software and is using because there is no fee and product that develop NMEA protocol Multiplexer, import mounting for foreign climax present. These method is paid or there is problem that must make out special processing part in each application program. Also, each mountings that display NMEA protocol can cause double resources waste and damage etc. because manufacturing firm and platform are different. Can act separatively as single hardware module of reliable processing method and high efficiency to supplement this in this treatise, and because using design of optimized cue, heighten memory efficiency of module, and proposed NMEA protocol Multiplexer that can keep high trustability of Come on, deviation compass, echo sound, mountings of GPS and so on and real time communication that is main input sensor equipment about embodiment.

  • PDF

A Development of Ultrasonic Based Distance Meter Through Detachment of Receiving and Transmitting Capacitive Ultrasonic Transducer (송.수신 분리형 초음파 거리 측정기 개발)

  • Kim Jung-Hoon;Chong Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.3 s.309
    • /
    • pp.41-50
    • /
    • 2006
  • This paper presents a novel ultrasonic sensor system to overcome limited distance detection range that can be measured only more than 30cm by single ultrasonic transducer. This is accomplished by separation of receiving capacitive ultrasonic transducer from transmitting capacitive ultrasonic transducer. And hardwares and software of the system are described in detail. The system makes very close range as well as long range detect by wireless precisely. Frequency of trigger pulse is 10Hz, but it is very low frequency for transmitting data in wireless module. Therefore, for triggering between receiver and transmitter, an algorithm for mixing and distinguishing trigger pulse from carrier pulse by software is proposed. The system is designed by common microprocessor 8051. The performance of the proposed method has been assessed through two types. The first, transmitting and receiving transducer are put on both sides. And then, distance of two point is measured as far as 0mm. Secondly, transmitting transducer send out ultrasonic pulse and measure the time of flight(TOF) until a first echo from an object detected by the detached receiving transducer. The distance between the detached transducers and a reflecting object is measured as far as 7cm. Images of measured ultrasonic waves and TOF for two methods presented to prove effectiveness of results.

Some Physical Oceanographic Survey in the Sea Off Kori (고리해역에 있어서의 표류병 및 염료확산시험)

  • Chang, Jee-Won;Park, Shi-Yohl;Soh, Doo-Ok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1971
  • The forth dye diffusion experiment, which was authorized by the Office of Atomic Energy, and some physical aspect of oceanographic observations were carried out in the sea off Kori in September 29-October 1, 1971. In a series of drift bottle experiments the 337 bottles were released. And bottom topography by echo soundings in the survey was well approached to the chart No. 433, Kori and Approaches, published by Hydrographic Office in October 1970. Results deduced from this survey were as follows: 1. A small ridge extends from Kori-Mal tip in southwestward over 1300 meters, and eastside of which is plain and a little sloping while westside of which cliffy and very steeper sloping. 2. A gyre was formed in the waters from Kori-Mal to Mat-dum in cum sole definitely at flood tide and in contra solem less definitely at ebb tide. And that the gyre rose and decayed with the turn of the tide. 3. Diffusion coefficients of 2.5% Rhodamine B solution of 200 liters were 9. 3 ${\times}{10^2}$ c$m^2$/sec in the waters Kori-Mal to Mat-dum and 28.6${\times}{10^2}$ c$m^2$/sec in the waters eastside of Mat-dum at the time after 26 minutes from releasing of the dye solution. 4. According to the above results the eastside of Mat-dum is rather recommendable to settle as the point for the outlet of drainage or waste of atomic power plant to be constructed.

  • PDF

Use of office-based ultrasonography for soft tissue lesions : A report of 3 cases with literature review (안면부 연조직 진단에서 외래기반 초음파의 사용 : 증례 보고(3례) 및 문헌 고찰)

  • Kim, Jae-Young;Kim, Min-Kyu;Lee, Sung-Hwa;Kim, Hyung Jun;Nam, Woong
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.143-152
    • /
    • 2015
  • Ultrasonography is relatively inexpensive, non-invasive imaging tool and provides real-time imaging. In addition, the images can be obtained repeatedly. But it is not widely used by dentists because it is hard to interpret and technique sensitive. Above all, ultrasonography cannot be used for hard tissue diagnosis. However, ultrasonography can be applied for diagnosis of infection, soft tissue tumor and inflammatory muscle diseases which are commonly found in dental outpatients. Generally, it shows well-defined border, hypoechoic and homogenous structure in case of benign tumor. Malignant tumor appears relatively irregular margin and heterogenous structure. Cyst represents relatively echo-free features compared with benign tumor. Although the general characteristics of abscess are similar with benign tumor, we can observe an increased vascularity and different clinical features. The purpose of this report is to present 3 cases of US images using office-based ultrasonography with their features and discuss the role of office-based ultrasound in dentistry for diagnosis of soft tissue lesions with literature review.

Hepatic Lipid Changes in Fatty Liver Rat Model by In Vivo Short-TE 1H-MRS (생체 내 양성자 자기공명분광법을 이용한 지방간 쥐에서 간 지질 변화)

  • Kim, Joo-Yeon;Baek, Hyeon-Man
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.623-630
    • /
    • 2018
  • Non-alcoholic fatty liver disease is the most common cause of chronic liver diseases. This study was to characterize early hepatic lipid changes in fatty liver rat model by in vivo short-echo time(TE) $^1H$-MRS(Proton - Magnetic Resonance Spectroscopy). Each the examinations were measured from liver parenchyma in rats at 0, 2, 4, 6, 8 weeks followed by high fat diet, respectively. Significant increase in lipid signals. 0.9, 1.3, 2.3, 2.8, and 5.3 ppm was found in animals with 2 weeks(p<0.01). Therefore, $^1H$-MRS is useful in detecting and characterizing various hepatic lipid alterations as early as 2 weeks for the start high fat diet.

Evaluation of the Surface Crack by a Large Aperture Ultrasonic Probe (대구경 초음파 탐촉자를 이용한 표면균열 평가)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.180-185
    • /
    • 2004
  • Conventional ultrasonic examination to detect micro and small surface cracks is based on the pulse-echo technique using a normal immersion focused transducer with high frequency, or an angle-beam transducer generating surface waves. It is difficult to make an automatic ultrasonic system that can detect micro and small surface cracks and position in a large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of the transducer. In this study, a high-precision scanning acoustic microscope with a 10MHz large-aperture transducer has been used to assess the existence, position and depth of a surface crack from the real-time A, B, C scans obtained by exploiting the ultrasonic diffraction. The ultrasonic method with large aperture transducer has improved the accuracy of the crack depth assessment and also the scanning speed by ten times, compared with the conventional ultrasonic methods.