• Title/Summary/Keyword: eccentric structures

Search Result 145, Processing Time 0.027 seconds

Experimental compressive behavior of novel composite wall with different width-to-thickness ratios

  • Qin, Ying;Chen, Xin;Zhu, Xing-Yu;Xi, Wang;Chen, Yuan-Ze
    • Steel and Composite Structures
    • /
    • v.36 no.2
    • /
    • pp.187-196
    • /
    • 2020
  • Double skin composite wall system owns several structural merits in terms of high load-carrying capacity, large axial stiffness, and favorable ductility. A recently proposed form of truss connector was used to bond the steel plates to the concrete core to achieve good composite action. The structural behavior of rectangular high walls under compression and T-shaped high walls under eccentric compression has been investigated by the authors. Furthermore, the influences of the truss spacings, the wall width, and the faceplate thickness have been previously studied by the authors on short walls under uniform compression. This paper experimentally investigated the effect of width-to-thickness ratio on the compressive behavior of short walls. Compressive tests were conducted on three short specimens with different width-to-thickness ratios. Based on the test results, it is found that the composite wall shows high compressive resistance and good ductility. The walls fail by local buckling of steel plates and crushing of concrete core. It is also observed that width-to-thickness ratio has great influence on the compressive resistance, initial stiffness, and strain distribution across the section. Finally, the test results are compared with the predictions by modern codes.

Characteristics of wind-Induced Coupled Motion of Tapered and Setback Tall Buildings (비정형 초고층 건물의 바람에 의한 편심응답 특성)

  • Kim, Yong-Chul;Kanda, Jun;Tamura, Yukio
    • Journal of Korean Association for Spatial Structures
    • /
    • v.13 no.1
    • /
    • pp.79-86
    • /
    • 2013
  • For most of recent tall buildings, one characteristic is that their building shapes vary with height such as taper and setback, and this implies that the distribution of their structural components may also vary with height. Because of these structural variations, although the sectional shapes of these buildings are symmetric, it is difficult to say whether or not they are structurally symmetric. The acceleration responses of structurally asymmetric tall buildings are larger than those of non-eccentric buildings, thus raising the possibility of problems during strong winds and typhoons. This paper describes wind tunnel tests carried out using building models with height variations and acceleration response analyses, and discusses the resulting response characteristics. For tapered and setback buildings, although the across-wind accelerations are larger than those of a square building, the total root-mean-square accelerations remain small because of smaller along-wind and torsional rms accelerations. And it was found that the effects of statistical couplings between along-wind force and other two forces are negligible.

The Structrual Behavior of Eccentrically Loaded Hybrid FRP-Concrete Composite Columns (편심재하된 하이브리드 FRP-콘크리트 합성 기둥의 구조적 특성)

  • Choi, Jin-Woo;Seo, Su-Hong;Park, Joon-Soek;Joo, Hyung-Joong;Yoon, Soon-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.4
    • /
    • pp.1-8
    • /
    • 2013
  • Pile foundations constructed by the fiber reinforced polymer plastic piles have been used in coastal and oceanic regions in many countries. Generally, fiber reinforced polymer plastic piles are consisted of filament winding FRP which is used to wrap the outside of concrete pile to increase the axial load carrying capacity or pultruded FRP which is located in the core concrete to resist the bending moment arising due to eccentric loading. In this paper, the analytical procedures of hybrid concrete filled FRP tube flexural members are suggested based on the CFT design method. Moreover, the analytical results are compared with the experimental results to obtained by the previous researches. The results of comparison analyses are performed to estimate the accuracy of the analytical procedure for hybrid FRP-concrete composite compression test, members under eccentrical loading.

Design aspects for minimizing the rotational behavior of setbacks buildings

  • Georgoussis, George K.
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1049-1066
    • /
    • 2016
  • An approximate analysis is presented for multi-story setback buildings subjected to ground motions. Setback buildings with mass and stiffness discontinuities are common in modern architecture and quite often they are asymmetric in plan. The proposed analysis provides basic dynamic data (frequencies and peak values of base resultant forces) and furthermore an overview of the building response during a ground excitation. The method is based on the concept of the equivalent single story system, which has been introduced by the author in earlier papers for assessing the response of uniform in height buildings. As basic quantities of the dynamic response of elastic setback buildings can be derived by analyzing simple systems, a structural layout of minimum elastic rotational response can be easily constructed. The behavior of such structural configurations, which is basically translational into the elastic phase, is also examined into the post elastic phase when the strength assignment of the various bents is based on a planar static analysis under a set of lateral forces simulating an equivalent 'seismic loading'. It is demonstrated that the almost concurrent yielding of all resisting elements preserves the translational response, attained at the end of the elastic phase, to the post elastic one.

P-M Relations of Slender Welded Built-up Square CFT Column under Eccentric Loads (시공성을 향상시킨 용접조립 각형 CFT 편심 장주의 P-M 관계)

  • Lee, Seong-Hui;Choi, Sung-Mo;Kim, Young-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.23-31
    • /
    • 2015
  • CFST columns are structurally superior because the concrete inside the steel tubes prevents local buckling at the tubes and the tubes confine the concrete. And, the thickness of steel tube in CFST column has been thinner with development of high-strengh steel. The thinner the steel tube of a square CFST column is, the more local buckling is likely to occur. For this reason, we developed welded built-up square steel tube with stiffeners which are placed at the center of the tube width acts as an anchor. In this study, we conduct experimental test for three specimens of the 4m long span welded built-up square CFT column with parameters of L/D and D/t. And, the test results were compared with the analysis results by M-${\phi}$-P Program.

Thermopiezoelastic Nonlinear Dynamic Characteristics of Piezolaminated Plates (압전적층판의 열-압전-탄성 동적 비선형 작동특성)

  • Oh, Il-Kwon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.7 s.100
    • /
    • pp.836-842
    • /
    • 2005
  • Nonlinear dynamic characteristics of active piezolaminated plates are investigated with respect to the thermopiezoelastic behaviors. For largely deformed structures with small strain, the incremental total Lagrangian formulation is presented based on the virtual work principles. A multi-field layer-wise finite shell element is proposed for assuring high accuracy and non-linearity of displacement, electric and thermal fields. For dynamic consideration of thermopiezoelastic snap-through phenomena, the implicit Newmark's scheme with the Newton-Raphson iteration is implemented for the transient response of various piezolaminated models with symmetric or eccentric active layers. The bifurcate thermal buckling of symmetric structural models is first investigated and the characteristics of piezoelectric active responses are studied for finding snap-through piezoelectric potentials and the load-path tracking map. The thermoelastic stable and unstable postbuckling, thermopiezoelastic snap-through phenomena with several attractors are proved using the nonlinear time responses for various initial conditions and damping loss factors. Present results show that thermopiezoelastic snap-through phenomena can result in the difficulty of buckling and postbuckling control of intelligent structures.

Strength of Interior Plat Plate-Column Connections Subjected to Unbalanced Moment (불균등 휨모멘트를 받는 플랫 플레이트-기둥 접합부의 강도산정모델)

  • 최경규;박홍근
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.961-972
    • /
    • 2002
  • Flat plate structures under lateral load are susceptible to the brittle shear failure of plate-column connection. To prevent such brittle failure, strength and ductility of the connection should be ensured. However, according to previous studies, current design methods do not accurately estimate the strength of plate-column connection. In the present study, parametric study using nonlinear finite element analysis was performed for interior connections. Based on the numerical results, a design method for the connection was developed. At the critical sections around the connection coexist flexural moment and shear developed by lateral and gravity loads, and maximum allowable eccentric shear stresses were proposed based on the interactions between the flexural moment and shear, The proposed method can precisely predict the strength of the connection, compared with the current design provisions. The predictability of the proposed method was verified by the comparisons with existing experiments and nonlinear numerical analyses.

Single Bundle PCL Reconstruction with Remnant Preservation (잔여 조직을 보존한 단일 다발 후방십자인대 보강재건술)

  • Lee, Dong Chul;Kim, Won-Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.15 no.2
    • /
    • pp.125-131
    • /
    • 2011
  • Optimal treatment of the torn posterior cruciate ligament (PCL) remains controversial. The type of tibial fixation (transtibial vs inlay), the femoral tunnel position within the femoral footprint (central, eccentric or isometric), and the number of bundles in the reconstruction (single-bundle vs double-bundle) are controversial issues. The PCL has a better chance of spontaneously healing than the anterior cruciate ligament (ACL) because of a rich blood supply (near the branch of the middle genicular artery) and coverage with a thicker synovium. In general, for easier passage of the graft and full visualization of the original ligament attachment site during the precise positioning of the tunnel, the remaining PCL fibers are usually debrided during reconstruction. However, the remaining remnant structures would significantly contribute to the posterior stability of the knee joint, the healing of the graft, preserving proprioceptive function of the mechanoreceptors in the PCL. Double bundle PCL reconstruction may result in some surgical complications because of increased complexity of making tunnel. Therefore, single bundle PCL reconstruction with remnant preservation seems to be an effective procedure.

  • PDF

An Experimental Study on the Structural Behavior of Stub Columns with HSA800 High-strength Steels under Eccentric Loads (편심하중을 받는 건축구조용 고강도 강재(HSA800) 단주의 거동에 관한 실험적 연구)

  • Lee, Kangmin;Lee, Myung Jae;Oh, Young Suk;Oh, Keunyeong;Hong, Sungbin
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.4
    • /
    • pp.289-297
    • /
    • 2014
  • Recently, high performance steels have been utilized to structural materials in buildings and bridges with the demand for high-rise and long-span of main structures. In this paper, flexure-compression members with the high-strength steel were experimentally evaluated to satisfy the design criteria when stub columns fabricated with HSA800 steel were eccentrically loaded. This test was conducted on box-shaped and H-shaped steels stub columns with high-strength steel to verify the P-M interaction of members subjected to combined forces according to axial load ratios. The results showed that all specimens were satisfied the requirements of Korean Building Code(KBC2009) for using of structural members.

Partial Confinement Utilization for Rectangular Concrete Columns Subjected to Biaxial Bending and Axial Compression

  • Abd El Fattah, Ahmed M.;Rasheed, Hayder A.;Al-Rahmani, Ahmed H.
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.1
    • /
    • pp.135-149
    • /
    • 2017
  • The prediction of the actual ultimate capacity of confined concrete columns requires partial confinement utilization under eccentric loading. This is attributed to the reduction in compression zone compared to columns under pure axial compression. Modern codes and standards are introducing the need to perform extreme event analysis under static loads. There has been a number of studies that focused on the analysis and testing of concentric columns. On the other hand, the augmentation of compressive strength due to partial confinement has not been treated before. The higher eccentricity causes smaller confined concrete region in compression yielding smaller increase in strength of concrete. Accordingly, the ultimate eccentric confined strength is gradually reduced from the fully confined value $f_{cc}$ (at zero eccentricity) to the unconfined value $f^{\prime}_c$ (at infinite eccentricity) as a function of the ratio of compression area to total area of each eccentricity. This approach is used to implement an adaptive Mander model for analyzing eccentrically loaded columns. Generalization of the 3D moment of area approach is implemented based on proportional loading, fiber model and the secant stiffness approach, in an incremental-iterative numerical procedure to achieve the equilibrium path of $P-{\varepsilon}$ and $M-{\varphi}$ response up to failure. This numerical analysis is adapted to assess the confining effect in rectangular columns confined with conventional lateral steel. This analysis is validated against experimental data found in the literature showing good correlation to the partial confinement model while rendering the full confinement treatment unsafe.