Abstract
CFST columns are structurally superior because the concrete inside the steel tubes prevents local buckling at the tubes and the tubes confine the concrete. And, the thickness of steel tube in CFST column has been thinner with development of high-strengh steel. The thinner the steel tube of a square CFST column is, the more local buckling is likely to occur. For this reason, we developed welded built-up square steel tube with stiffeners which are placed at the center of the tube width acts as an anchor. In this study, we conduct experimental test for three specimens of the 4m long span welded built-up square CFT column with parameters of L/D and D/t. And, the test results were compared with the analysis results by M-${\phi}$-P Program.
Keywords
Concrete Filled Steel Tubular Column; Slender Column; Cold-Form; Anchor; Width to Thickness Ratio; Eccentricity Ratio;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ellobody, E. (2007) Nonlinear behavior of concrete-filled stainless steel stiffened slender tube columns, Thin-Walled Structures, 45, pp.259-273.   DOI   ScienceOn
2 Ge, H. and Usami, T. (1992) Strength of Concrete-Filled Thin-Walled Steel Box Columns: Experiment, Journal of Structural Engineering, 64(11), pp.3036-3054.
3 Hua,, H. T., Huang, C. S. and Chen, Z.-L. (2005) Finite element analysis of CFT columns subjected to an axial compressive force and bending moment in combination, Journal of Constructional Steel Research, 61, pp.1692-1712.   DOI   ScienceOn
4 Hajjar, J. F. and Gourley, B. C. (1996) Representation of concrete-filled steel tube cross-section strength, Journal of Structural Engineering, 122(11), pp.1327-1336.   DOI   ScienceOn
5 Han, L. H., Zhao, Z.-L. and Tao, Z. (2001) Tests and mechanics model for concrete-filled SHS stub columns, columns and beam-columns, Steel & Composite Structures, 1(1), pp.51-74.   DOI   ScienceOn
6 Lee, S. H., Choi, Y. H., Kim, Y. H. and Choi, S. M. (2012) Structural performance of welded built-up square CFST stub columns, Thin-Walled Structures, 52, pp.12-20.   DOI   ScienceOn
7 Mursi, M. and Uy, B. (2003) Strength of Concrete Filled Steel Box Columns Incorporating Interaction Buckling, Journal of Structural Engineering, 129(5), pp.626-639.   DOI   ScienceOn
8 Patel V. I., Liang, Q. Q. and Hadi, M. N.S. (2012) High Strength thin-walled rectangular concrete-filled steel tubular slender beam-columns, Part I: Modeling, Journal of Constructional Steel Research, 70, pp.377-384.   DOI   ScienceOn
9 Kim, J. M(1991), High school math formula book, Jung-ang academic institute
10 Park, J. W., Rhee, D. J., Chang, S. S. and Hu, J. W. (2012) Advanced Analysis of Connections to Concrete-Filled Steel Tube Columns using the 2005 AISC Specification, J. Korean Soc. Adv. Comp. Struc., Vol.3, No.3, pp.9-21   DOI   ScienceOn
11 Seon, W. H. and Hu, J. W. (2011) Development of A Component and Advanced Model for The Smart PR-CFT Connection Structure, J. Korean Soc. Adv. Comp. Struc., Vol.2, No.4, pp.1-10.   DOI
12 Uy, B. (1998) DUCTILITY, STRENGTH AND STABILITY OF CONCRETE-FILLED FABRICATED STEEL BOX COLUMNS FOR TALL BUILDINGS, Vol.7, pp.113-133.   DOI
13 Tao, Z., Han L. H., Wang, Z. B. (2005), Experimental behavior of stiffened concrete-filled thin-walled hollow steel structural (HSS) stub column, Journal of Constructional Steel Research, 61, pp.962-983.   DOI   ScienceOn