• Title/Summary/Keyword: dynamic scanning

Search Result 356, Processing Time 0.028 seconds

Comparison of the fracture resistances of glass fiber mesh- and metal mesh-reinforced maxillary complete denture under dynamic fatigue loading

  • Im, So-Min;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.22-30
    • /
    • 2017
  • PURPOSE. The aim of this study was to investigate the effect of reinforcing materials on the fracture resistances of glass fiber mesh- and Cr-Co metal mesh-reinforced maxillary complete dentures under fatigue loading. MATERIALS AND METHODS. Glass fiber mesh- and Cr-Co mesh-reinforced maxillary complete dentures were fabricated using silicone molds and acrylic resin. A control group was prepared with no reinforcement (n = 15 per group). After fatigue loading was applied using a chewing simulator, fracture resistance was measured by a universal testing machine. The fracture patterns were analyzed and the fractured surfaces were observed by scanning electron microscopy. RESULTS. After cyclic loading, none of the dentures showed cracks or fractures. During fracture resistance testing, all unreinforced dentures experienced complete fracture. The mesh-reinforced dentures primarily showed posterior framework fracture. Deformation of the all-metal framework caused the metal mesh-reinforced denture to exhibit the highest fracture resistance, followed by the glass fiber mesh-reinforced denture (P<.05) and the control group (P<.05). The glass fiber mesh-reinforced denture primarily maintained its original shape with unbroken fibers. River line pattern of the control group, dimples and interdendritic fractures of the metal mesh group, and radial fracture lines of the glass fiber group were observed on the fractured surfaces. CONCLUSION. The glass fiber mesh-reinforced denture exhibits a fracture resistance higher than that of the unreinforced denture, but lower than that of the metal mesh-reinforced denture because of the deformation of the metal mesh. The glass fiber mesh-reinforced denture maintains its shape even after fracture, indicating the possibility of easier repair.

Studies on the Improvement of Butt Welding Characteristic of Polyethylene Pipes (PE 이중벽관의 맞대기 융착 용접 강도 향상에 관한 연구)

  • An, Ju-Seon;Lee, Kyng-Won;Kim, Jae-Sung;Lee, Bo-Young
    • Journal of Welding and Joining
    • /
    • v.29 no.1
    • /
    • pp.85-89
    • /
    • 2011
  • Waste water is disposed to sewage disposal plant by underground PE double wall pipes. Various processes have been introduced to join PE pipes, but most of these methods have many disadvantages such as costs, lack of reliability and difficulties in joining, etc. Recently butt welding has been paid much attention to joint PE pipes as this process has many advantages such as cost, safety and reliability. In this study, newly developed heat plate, a patent-pending heat plate with a groove, was used to butt-weld PE double wall pipes with different misalignment gaps to simulate real underground conditions, and the butt welding temperature of PE pipe was determined by thermal analysis (Thermal Gravimetric Analysis, Differential Scanning Calorimetry and Dynamic Mechanical Analysis). The resulting joining characteristics of double wall pipes were compared with those from a conventional heat plate, in terms of stiffness, flattening and leakage tests. The results from the stiffness and flattening test showed that there were no big differences between the butt-welded joints made from these two plates. From the leakage test, although PE pipes welded with a conventional heat plate did leak below the required test conditions (10 min. at 0.75kgf/cm2), the pipes welded with a patent-pending grooved heat plate did not show any leakage even at a pressure 1.5 times higher than the required conditions. It was noted that by utilizing a grooved heat plate more complete fusion at the pipe joints could be obtained, which in turn induced a high quality joints.

Characteristic of Underfill with Various Epoxy Resin (에폭시 수지에 따른 언더필의 특성에 관한 연구)

  • Noh, Bo-In;Lee, Jong-Bum;Jung, Seung-Boo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.39-45
    • /
    • 2006
  • This study was investigated the thermal properties of underfill with various epoxy resins using thermal analysis methods such as differential scanning calorimetry (DSC), thermo gravimetry analysis (TGA), dynamic mechanical analysis (DMA) and thermo-mechanical analysis (TMA). And, the adhesion strength of the underfills/FR-4 substrate was evaluated. The glass transition temperature (Tg) of underfill which was composed the cycolaliphatic epoxy resin was lower than that of underfill which was not composed the cycolaliphatic epoxy resin. The thermal degradation of underfill was composed of two processes, which involved chemical reactions between the degrading polymer and oxygen from the air atmosphere. The coefficient of thermal expansion (CTE) of underfill which was composed the cycolaliphatic epoxy resin was higher than that of underfill which was not composed the cycolaliphatic epoxy resin. The excessive curing temperatures caused a weak boundary layer of epoxy resin, which resulted in a deterioration of mechanical properties in the epoxy resin and thus led to poor adhesion property between the underfill/FR-4 substrate.

  • PDF

Nucleation Enhancing Effect of Different ECR Plasmas Pretreatment in the RUO2 Film Growth by MOCVD (ECR플라즈마 전처리가 RuO2 MOCVD시 핵생성에 끼치는 효과)

  • Eom, Taejong;Park, Yunkyu;Lee, Chongmu
    • Journal of the Korean Ceramic Society
    • /
    • v.42 no.2 s.273
    • /
    • pp.94-98
    • /
    • 2005
  • $RuO_2$ is widely studied as a lower electrode material for high dielectric capacitors in DRAM (Dynamic Random Access Memories) and FRAM (Ferroelectric Random Access Memories). In this study, the effects of hydrogen, oxygen, and argon Electron Cyclotron Resonance (ECR) plasma pretreatments on deposited by Metal Organic Chemical Vapor Deposition (MOCVD) $RuO_2$ nucleation was investigated using X-Ray Diffraction (XRD), Scanning Electron Microscopy (SEM), and Atomic Force Microscopy (AFM) analyses. Argon ECR plasma pretreatment was found to offer the highest $RuO_2$ nucleation density among these three pretreatments. The mechanism through which $RuO_2$ nucleation is enhanced by ECR plasma pretreatment may be that the argon or the hydrogen ECR plasma removes nitrogen and oxygen atoms at the TiN film surface so that the underlying TiN film surface is changed to Ti-rich TiN.

Mechanical Properties of EPDM Gasket after Long-Term Operations (EPDM 가스켓의 장시간 운전에 따른 기계적 성능변화)

  • Wu, Lan;Kim, Seon-Hak;Cheon, Seung-Ho;Kim, Jin-Su;Hyun, Deok-Su;Kim, Byeong-Heon;Lee, Sung-Kun;Jeong, Jae-Hoon;Ji, Duk-Jin;Oh, Byeong-Soo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.4
    • /
    • pp.488-494
    • /
    • 2011
  • Gasket plays an important role on sealing of the polymer electrolyte membrane fuel cell (PEMFC) stack. Stack requires gaskets in each cell to keep the hydrogen and air/oxygen within their respective regions. The failure of the gasket creates the problems of fuel leakage, mixing, damage on parts and can be a direct reason for the degrading the efficiency of fuel cell. The purpose of this paper researches on how mechanical properties of EPDM gasket in PEMFC are changed after long-term operations. The EPDM (ethylenepropylene-diene monomer) gaskets are obtained from the stack after long-term operations. DMA (dynamic mechanical analysis) is conducted to access the change of mechanical properties of the EPDM gasket. SEM/EDS (scanning electron microscope/energy dispersive spectroscopy) was used to show the surface topography and chemical characterization on the sample surface.

Development of Polymeric Nanopaclitaxel and Comparison with Free Paclitaxel for Effects on Cell Proliferation of MCF-7 and B16F0 Carcinoma Cells

  • Yadav, Deepak;Anwar, Mohammad Faiyaz;Garg, Veena;Kardam, Hemant;Beg, Mohd Nadeem;Suri, Suruchi;Gaur, Sikha;Asif, Mohd
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.5
    • /
    • pp.2335-2340
    • /
    • 2014
  • Paclitaxel is hydrophobic in nature and is recognized as a highly toxic anticancer drug, showing adverse effects in normal body sites. In this study, we developed a polymeric nano drug carrier for safe delivery of the paclitaxel to the cancer that releases the drug in a sustained manner and reduces side effects. N-isopropylacrylamide/vinyl pyrrolidone (NIPAAm/VP) nanoparticles were synthesized by radical polymerization. Physicochemical characterization of the polymeric nanoparticles was conducted using dynamic light scattering, transmission electron microscopy, scanning electron microscopy and nuclear magnetic resonance, which confirmedpolymerization of formulated nanoparticles. Drug release was assessed using a spectrophotometer and cell viability assays were carried out on the MCF-7 breast cancer and B16F0 skin cancer cell lines. NIPAAm/VP nanoparticles demonstrated a size distribution in the 65-108 nm range and surface charge measured -15.4 mV. SEM showed the nanoparticles to be spherical in shape with a slow drug release of ~70% in PBS at $38^{\circ}C$ over 96 h. Drug loaded nanoparticles were associated with increased viability of MCF-7 and B16F0 cells in comparison to free paclitaxel. Nano loaded paclitaxel shows high therapeutic efficiency by sustained release action for the longer period of time, i increasing its efficacy and biocompatibility for human cancer therapy. Therefore, paclitaxel loaded (NIPAAm/VP) nanoparticles may provide opportunities to expand delivery of the drug for clinical selection.

Annealing Effect in the Cold-Plastic Deformation of Amorphous PET Material (무정형 PET 재료의 플라스틱 냉간 변형에서의 열처리 효과)

  • Lee, Jong-Young;Park, Seong-Soo
    • Polymer(Korea)
    • /
    • v.25 no.1
    • /
    • pp.56-62
    • /
    • 2001
  • When polyethylene terephthalate(PET) film specimen were stepwise elongated under tension with various speeds of about 0.5~500 mm/min, the necking area, consisted of transparent and opaque bands, was formed during plastic deformation. Stress oscillation was apparently obtained in the stress-strain curve of above specimen. However, stress oscillation was not obtained in the stress-strain curve of annealing specimen. Microstructure was examined dynamically using an optical microscopy and thermal analysis was carried out in a differential scanning calorimeter at a heating rate of 10${\circ}$/min. Also, orientation and crystallization were examined using monochromatic-pinhole technique and elastic modulus was measured by a dynamic mechanical analyzer in the temperature range of -150~70 ${\circ}$ with the frequency of 1 Hz. Transparent PET products were fabricated by use of the PET pellets annealed at 83${\circ}$ for 30 min in an electric furnace.

  • PDF

Electrical Resistivity and Mechanical Properties of Polypropylene Composites Containing Carbon Nanotubes and Stainless Steel Short Fibers (탄소나노튜브와 스테인레스강 단섬유를 함유한 폴리프로필렌 복합체의 전기저항 및 기계적 특성)

  • Jung, Jong Ki;Park, Kihun;Bang, Daesuk;Oh, Myunghoon;Kim, Bongseok;Lee, Jong Keun
    • Polymer(Korea)
    • /
    • v.38 no.2
    • /
    • pp.250-256
    • /
    • 2014
  • Polypropylene (PP) composites containing conductive multi-walled carbon nanotube (MWNT) and stainless steel short fiber (SSF) were manufactured using a twin screw extruder and characterized their surface resistivity and mechanical properties in this work. Surface resistivity measurements showed that the percolation threshold appeared at a lower MWNT loading when a small amount of SSF was added to PP/MWNT composites. Tensile modulus and strength of the composites increased but elongation-at-break decreased greatly compared to pure PP. Also, the effects of MWNT and SSF on storage modulus and tan ${\delta}$ from dynamic mechanical analysis for the composites were examined, and the morphologies of fractured surface and the fillers were observed using a scanning electron microscope.

The Characteristics of (Ba,Sr)$TiO_3$ Thin Films Etched With The high Density $BCl_3/Cl_2$/Ar Plasma ($BCl_3/Cl_2$/Ar 고밀도 플라즈마에서 (Ba,Sr)$TiO_3$ 박막의 식각 특성에 관한 연구)

  • Kim, Seung-Bum;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.863-866
    • /
    • 1999
  • (Ba,Sr)$TiO_3$ thin films have attracted groat interest as new dielectric materials of capacitors for ultra-large-scale integrated dynamic random access memories (ULSI-DRAMs) such as 1 Gbit or 4 Gbit. In this study, inductively coupled $BCl_3/Cl_2$/Ar plasmas was used to etch (Ba,Sr)$TiO_3$ thin films. RF power/dc bias voltage = 600 W/-250 V and chamber pressure was 10 mTorr. The $Cl_2/(Cl_2+Ar)$ was fixed at 0.2, the (Ba,Sr)$TiO_3$ thin films were etched adding $BCl_3$. The highest (Ba,Sr)$TiO_3$ etch rate is 480$\AA/min$ at 10 % $BCl_3$ adding to $Cl_2$/Ar. The characteristics of the plasmas were estimated using optical emission spectroscopy (OES). The change of Cl, B radical density measured by OES as a function of $BCl_3$ percentage in $Cl_2$/Ar. The highest Cl radical density was shown at the addition of 10% $BCl_3$ to $Cl_2$/Ar. To study on the surface reaction of (Ba,Sr)$TiO_3$ thin films was investigated by XPS analysis. Ion enhancement etching is necessary to break Ba-O bond and to remove $BaCl_2$. There is a little chemical reaction between Sr and Cl, but Sr is removed by physical sputtering. There is a chemical reaction between Ti and Cl, and Tic14 is removed with ease. The cross-sectional of (Ba,Sr)$TiO_3$ thin film was investigated by scanning electron microscopy (SEM), the etch slope is about $65\;{\sim}\;70$.

  • PDF

Efficient Implementation of Synthetic Aperture Imaging with Virtual Source Element in B-mode Ultrasound System Based on Sparse Array (희박 어레이 기반의 효율적인 양방향 화소단위 집속 기법의 구현)

  • 김강식;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.6
    • /
    • pp.419-430
    • /
    • 2002
  • In this paper. we propose an efficient method for implementing hi-directional pixel-based focusing(BiPBF) based on a sparse array imaging technique. The proposed method can improve spatial resolution and frame rate of ultrasound imaging with reduced hardware complexity by synthesizing transmit apertures with a small number of sparsely distributed subapertures. As the distance between adjacent subapertures increases, however. the image resolution tends to decrease due to the elevation of grating lobes. Such grating lobes can be eliminated in conventional synthetic aperture imaging techniques. On the contrary, grating lobes arisen from employing sparse synthetic transmit apertures can not be eliminated, which has been shown analytically in this paper. We also propose the condition and method for suppressing the grating lobes below -40dB, which is generally required in practical imaging. by placing the transmit focal depth at a near depth and properly selecting the subaperture distance in Proportion to receive aperture size. The results of both the Phantom and in vivo experiments show that the proposed method implements two-wav dynamic focusing using a smaller number of subapertures, resulting in reduced system complexity and increased frame rate.