• Title/Summary/Keyword: dynamic filtration

Search Result 42, Processing Time 0.025 seconds

Dynamic Characteristics for the Separation of Inulin Solution in Membrane Filtrsition System of Tangential Flow (접선류 막분리 시스템에 의한 이눌린 수용액의 분리 동특성)

  • 허병기;배천순이기정목영일
    • KSBB Journal
    • /
    • v.5 no.1
    • /
    • pp.69-74
    • /
    • 1990
  • Dynamic characteristics of separation in membrane filtration system of tangential flow was investigated to find the functional relationship among the filtrate flux, transmembrane pressure, inulin concentration and recirculation rate. In case that NMWL is 1000, tracts-membrane pressure $0.4kgf/\;{\textrm{cm}^2}$ to $3.2kgf/\;{\textrm{cm}^2}$, inulin concentration lwt% to 5wt%, and recirculation rate 4ml / sec, mathematical model for the function among filtrate flux, transmembrane pressure, and inulin concentration was deduced and expressed as follows.Jv = (0.0022p + 0.0003) ln \frac{3p\;+\;2.1}{C_b}$ The values calculated by the above equation and those measured were compared to find to be nicely in accord with each other. Especially the agreement was enhanced in the region of higher concentration of inulin.

  • PDF

Nanoporous graphene oxide membrane and its application in molecular sieving

  • Fatemi, S. Mahmood;Arabieh, Masoud;Sepehrian, Hamid
    • Carbon letters
    • /
    • v.16 no.3
    • /
    • pp.183-191
    • /
    • 2015
  • Gas transport through graphene-derived membranes has gained much interest recently due to its promising potential in filtration and separation applications. In this work, we explore Kr-85 gas radionuclide sequestration from natural air in nanoporous graphene oxide membranes in which different sizes and geometries of pores were modeled on the graphene oxide sheet. This was done using atomistic simulations considering mean-squared displacement, diffusion coefficient, number of crossed species of gases through nanoporous graphene oxide, and flow through interlayer galleries. The results showed that the gas features have the densest adsorbed zone in nanoporous graphene oxide, compared with a graphene membrane, and that graphene oxide was more favorable than graphene for Kr separation. The aim of this paper is to show that for the well-defined pore size called P-7, it is possible to separate Kr-85 from a gas mixture containing Kr-85, O2 and N2. The results would benefit the oil industry among others.

The Evaluation of Drainage Characteristics Using a New Drainage Tester (새로운 탈수측정 설비를 이용한 탈수 특성 평가)

  • 김용식;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.3
    • /
    • pp.1-9
    • /
    • 2000
  • The MDDA (Modified Dynamic Drainage Analyzer) was developed to evaluate the drainage characteristics on paper machine. The initial forming vacuum velocity was decreased with the increase of stock consistency and there were no significant effects of the applied vac-uum. On the other hand the initial forming drainage velocity was rapidly decreased with the increase of stock consistency above the 0.35 bar of applied vacuum. The final drainage time and wet web permeability showed similar trends under 0.075% consistency but increased rapidly at the higher consistencies. SFR(Specific Filtration Resistance) and drainage obtained for different vacuum level applied and deposited weights measured by using MDDA showed the linear relationship.

  • PDF

Estimation of longitudinal velocity noise for rail wheelset adhesion and error level

  • Soomro, Zulfiqar Ali
    • Multiscale and Multiphysics Mechanics
    • /
    • v.1 no.3
    • /
    • pp.261-270
    • /
    • 2016
  • The longitudinal velocity (forward speed) having significant importance in proper running of railway wheelset on track, depends greatly upon the adhesion ratio and creep analysis by implementation of suitable dynamic system on contamination. The wet track condition causes slip and slide of vehicle on railway tracking, whereas high speed may also increase slip and skidding to severe wear and deterioration of mechanical parts. The basic aim of this research is to design appropriate model aimed estimator that can be used to control railway vehicle forward velocity to avoid slip. For the filtration of disturbance procured during running of vehicle, the kalman filter is applied to estimate the actual signal on preferered samples of creep co-efficient for observing the applied attitude of noise. Thus error level is detected on higher and lower co-efficient of creep to analyze adhesion to avoid slip and sliding. The skidding is usually occurred due to higher forward speed owing to procured disturbance. This paper guides to minimize the noise and error based upon creep coefficient.

Preparation, characterization and comparison of antibacterial property of polyethersulfone composite membrane containing zerovalent iron or magnetite nanoparticles

  • Dizge, Nadir;Ozay, Yasin;Simsek, U. Bulut;Gulsen, H. Elif;Akarsu, Ceyhun;Turabik, Meral;Unyayar, Ali;Ocakoglu, Kasim
    • Membrane and Water Treatment
    • /
    • v.8 no.1
    • /
    • pp.51-71
    • /
    • 2017
  • Antimicrobial polyethersulfone ultrafiltration membranes containing zerovalent iron ($Fe^0$) and magnetite ($Fe_3O_4$) nanoparticles were synthesized via phase inversion method using polyethersulfone (PES) as membrane material and nano-iron as nanoparticle materials. Zerovalent iron nanoparticles (nZVI) were prepared by the reduction of iron ions with borohydride applying an inert atmosphere by using $N_2$ gases. The magnetite nanoparticles (nMag) were prepared via co-precipitation method by adding a base to an aqueous mixture of $Fe^{3+}$ and $Fe^{2+}$ salts. The synthesized nanoparticles were characterized by scanning electron microscopy, X-ray powder diffraction, and dynamic light scattering analysis. Moreover, the properties of the synthesized membranes were characterized by scanning electron microscopy energy dispersive X-ray spectroscopy and atomic force microscopy. The PES membranes containing the nZVI or nMag were examined for antimicrobial characteristics. Moreover, amount of iron run away from the PES composite membranes during the dead-end filtration were tested. The results showed that the permeation flux of the composite membranes was higher than the pristine PES membrane. The membranes containing nano-iron showed good antibacterial activity against gram-negative bacteria (Escherichia coli). The composite membranes can be successfully used for the domestic wastewater filtration to reduce membrane biofouling.

Solid-Liquid Separation Characteristics with Bio-filter Media Reactor (여과분리형 생물반응조의 고액분리 특성)

  • Park, Young Bae;Jung, Yong Jun
    • Journal of Wetlands Research
    • /
    • v.16 no.3
    • /
    • pp.347-353
    • /
    • 2014
  • This work was performed to find the effect of operation parameters on the permeate flux through the activated sludge dynamic layer, and to indicate the relationship between the water quality of supernatant and flux based on the results. Since the effluent can be obtained through steady and stable formation of cake layer in the bio-filter media system, it is an important subject to keep and control microbes with activated state in the bio-reactor. Filtration resistance was drastically increased at more than 18000mg/L of MLSS. With filtration time continued, the flux was gradually decreased and the water qualities of supernatant monitored by turbidity and TOC were also deteriorated. This phenomenon indicated that the organic materials generated by microbes and accumulated in the reactor might affect the flux in the system. In addition, the decrease of flux was simultaneously observed in the sludge volume index. When SVI was controlled from 150 to 250, the flux was also decreased. The proper aeration time was recommended to 30 to 60 seconds in this system. In order to operate this system steadily, therefore, the control of water quality of supernatant and SVI should be proceeded.

Experimental Evaluation Method of Mass Transfer Coefficient on Biotrickling Filtration for Air Pollution Control (대기오염제어를 위한 생물살수여과법에서 물질전달계수 실험평가방법에 관한 연구)

  • Won, Yang-Soo;Jo, Wan-Keun
    • Korean Chemical Engineering Research
    • /
    • v.53 no.4
    • /
    • pp.482-488
    • /
    • 2015
  • Biological treatment is promising alternative to conventional air pollution control method. Bioreactors for air pollution control have found most of their success in the treatment of dilute and high flow waste air streams containing volatile organic compounds and odor. The studies of mass transfer in biotrickling filters for air pollution control were of importance in order to control and optimize the purification process. The objectives of this study were to develop the experimental methodologies to evaluate the mass transfer coefficients of gas/liquid(trickling liquid), gas/solid(biomass) and liquid/solid in three phase biotrickling filtration. Also, this study characterized the influence factors on mass transfer such as dynamic holdup volume, gas/liquid flow rate ratio, biomass weight in reactor and recirculation rate of trickling medium for each phase of biotrickling filter.

An application of operational deflection shapes and spatial filtration for damage detection

  • Mendrok, Krzysztof;Wojcicki, Jeremi;Uhl, Tadeusz
    • Smart Structures and Systems
    • /
    • v.16 no.6
    • /
    • pp.1049-1068
    • /
    • 2015
  • In the paper, the authors propose the application of operational deflection shapes (ODS) for the detection of structural changes in technical objects. The ODS matrix is used to formulate the spatial filter that is further used for damage detection as a classical modal filter (Meirovitch and Baruh 1982, Zhang et al. 1990). The advantage of the approach lies in the fact that no modal analysis is required, even on the reference spatial filter formulation and other components apart from structural ones can be filtered (e.g. harmonics of rotational velocity). The proposed methodology was tested experimentally on a laboratory stand, a frame-like structure, excited from two sources: an impact hammer, which provided a wide-band excitation of all modes, and an electro-dynamic shaker, which simulated a harmonic component in the output spectra. The damage detection capabilities of the proposed method were tested by changing the structural properties of the model and comparing the results with the original ones. The quantitative assessment of damage was performed by employing a damage index (DI) calculation. Comparison of the output of the ODS filter and the classical modal filter is also presented and analyzed in the paper. The closing section of the paper describes the verification of the method on a real structure - a road viaduct.

Effects of EPS on membrane fouling in a hybrid membrane bioreactor for municipal wastewater treatment

  • Zhang, Aining;Liu, Zhe;Chen, Yiping;Kuschk, Peter;Liu, Yongjun
    • Membrane and Water Treatment
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 2014
  • A pilot-scale hybrid membrane bioreactor (HMBR) for real municipal wastewater treatment was developed by adding biofilm carriers into a conventional membrane bioreactor, distribution and dynamic changes of the extracellular polymeric substances (EPS) and their roles in membrane fouling were investigated. The results showed that the concentrations of loosely bond EPS (LB-EPS) and tightly bond EPS (TB-EPS) in activated sludge, carrier biofilm and sludge cake layer have been increased significantly with the running time of HMBR, during operation of the HMBR, EPS demonstrated positive correlations with membrane fouling. Compared to TB-EPS, LB-EPS showed more significant correlations with sludge physical properties and specific resistance to filtration (SRF) in HMBR, and thus demonstrated that LP-EPS have a stronger potential of fouling than TB-EPS. It was also found that a lower organic loading in HMBR could result a significant increase in EPS concentration, which would in turn influence membrane fouling in HMBR. This critical investigation would contribute towards a better understanding of the behavior, composition and fouling potential of EPS in HMBR operation.

Cost-effective polyvinylchloride-based adsorbing membrane for cationic dye removal

  • Namvar-Mahboub, Mahdieh;Jafari, Zahra;Khojasteh, Yasaman
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.131-139
    • /
    • 2020
  • The current study focused on the preparation of low-cost PVC-based adsorbing membrane. Metakaolin, as available adsorbent, was embedded into the PVC matrix via solution blending method. The as-prepared PVC/metakaolin mixed matrix membranes were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, atomic force microscopy (AFM), pure water permeability and contact angle measurements. The results confirmed the improvement of PWP and hydrophilicity due to the presence of metakaolin in the PVC matrix. Additionally the structure of PVC membrane was changed due to the incorporation of metakaolin in the polymer matrix. The static adsorption capacity of all samples was determined through dye removal. The effect of metakaolin dosage (0-7%) and pH (4, 8, 12) on dye adsorption capacity was investigated. The results depicted that the highest adsorption capacity was achieved at pH of 4 for all samples. Additionally, adsorption data were fitted on Langmuir, Freundlich, and Temkin models to determine the appropriate governing isotherm model. Finally, the dynamic adsorption capacity of the optimum PVC/metakaolin membrane was studied using dead-end filtration cell. The dye removal efficiency was determined for pure PVC and PVC/metakaolin membrane. The results demonstrated that PVC/metakaolin mixed matrix membrane had a high adsorption capacity for dye removal from aqueous solution.