• Title/Summary/Keyword: duty efficiency

Search Result 448, Processing Time 0.026 seconds

Off-time Control Method for High Power Density AC/DC Adapter (고전력밀도 AC/DC Adapter를 위한 off-time 제어법)

  • Kang, Shin-Ho;Jang, Jun-Ho;Hong, Sung-Soo;Lee, Jun-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.12 no.6
    • /
    • pp.510-516
    • /
    • 2007
  • The proposed method offers an improved control method for high power density AC/DC adapter by using more energy efficient electrical equipments. Power factor correction (PFC) topology is based on boost topology with boundary conduction mode (BCM). DC/DC topology is based on half-bridge topology with fixed 50% duty and newly introduced off-time control method, which helps to reduce size of the semiconductor and the magnetic devices. Test results with 85W AC/DC adapter (18.5V/4.6A) design show that the measured efficiency is 90% with power density of $36W/in^3$. It also shows low no load power consumption of about 0.5W.

A Study on Duty and System and Work Environment of the Turnover Factors among Bakery Employees at Tourist Hotel (호텔 베이커리 종사원의 직무, 조직, 작업환경이 이직의도에 미치는 영향에 관한 연구)

  • 안호기
    • Culinary science and hospitality research
    • /
    • v.10 no.3
    • /
    • pp.32-50
    • /
    • 2004
  • The purpose of this study was to examine what caused bakery employees at tourist hotel to leave their job. It's basically meant to lay the foundation for increasing personnel management efficiency and reducing turnover rate, as an attempt to prevent workers from quiting their jobs would be a successful way to take advantage of human resources more efficiently. Both theoretical and experimental approaches were utilized to serve the purpose of this study. First, concerning salaries, their turnover intention was under the influence of whether they were properly paid or gained a sufficient living. Second, as for environmental factors, their turnover intention was affected by performance appraisal and interpersonal trust with colleagues. Third, regarding job-related factors, their turnover intention was impacted by whether their job was clearly defined, how much they were satisfied with their job and whether their posts were suitable. Forth, the change of job was subjected to the influence of the desire for job in another region, job in another company and another kind of job. And there should be a clear distinction between sales and other works, and they should carefully be treated so that they could find their job more satisfactory.

  • PDF

Design of Non-Dissipative Snubber for Current-Fed Half-bridge Converter Operating at Duty Ratio above 0.5 (0.5보다 큰 시비율로 동작하는 전류원 하프-브릿지 컨버터의 무손실 스너버 설계)

  • 강정일;한상규;윤현기;김정은;윤명중;김윤호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.7 no.5
    • /
    • pp.405-412
    • /
    • 2002
  • Since the switching device of current-fed bridge-type topology suffers from him-off voltage spikes associated with larger energy than that of voltage-fed topology, a high-efficiency non-dissipative snubber is considered essential. However, the complicated operation and the capricious performance according to various conditions make the design of the non-dissipative difficult. In this paper, the non-dissipative snubber employed in the current-fed half-bridge converter operating at a duty ratio above 0.5 is completely analyzed and the design considerations are discussed. Some design examples and the experimental results are provided to confirm the analysis and design presented in this paper.

Task Scheduling Technique for Energy Efficiency in Wireless Sensor Networks (무선 센서 네트워크 환경에서의 에너지 효율성을 고려한 태스크 스케줄링 기법)

  • Lee Jin-Ho;Choi Hoon;Baek Yun-Ju
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.9A
    • /
    • pp.884-891
    • /
    • 2006
  • A wireless sensor node is typically battery operated and energy constrained. Therefore it is critical to design efficient power management technique and scheduling technique. In this paper, we propose an OS-level power management technique for energy saving of wireless sensor node, it is called EA-SENTAS (Energy-Aware Sensor Node TAsk Scheduling). It can decrease the energy consumption of a wireless sensor node to use task scheduling technique that shut down components or use low power mode of each component when not needed. Simulation results show that EA-SENTAS saves energy up to 56 percent to compare with conventional duty cycle.

Comparison of Correlation between CVS-75 Mode and Korea Mode to Estimate Emission Factors from Vehicles (자동차 오염물질 배출계수 산정을 위한 CVS-75모드와 국내차속모드의 상관성 비교 연구)

  • Jung, Sung-Woon;Ryu, Jeong-Ho;Lyu, Young-Sook
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.22 no.3
    • /
    • pp.383-391
    • /
    • 2006
  • In Korea, the major source of serious air pollution is motor vehicles. Air pollution from vehicles has been annually increased. Then the government will try to control the vehicle emission by applying the effective emission management policy for the manufactured and in-used car. It is necessary to correctly calculate the emission factor for successful propulsion of the vehicle emission control policy. In this study, correlation analysis of exhaust emissions from vehicles between CVS-75 mode and Korea mode was conducted. A total of 25 light-duty buses were tested on the chassis dynamometer system in order to measure CO, HC, NOx PM and fuel efficiency (F.E.). For the test modes, 10 different Korea modes and CVS-75 mode were used. As the result of correlation analysis between those modes, most of the correlation coefficients were higher than 0.90. On the basis of high correlation between those modes, correction factors by driving conditions were estimated. Through the results of this study, we obtained essential basic data to correct difference from those modes.

Grid-tied Power Conditioning System for Battery Energy Storage Composed of 2-stage DC-DC converter (2단 DC-DC 컨버터로 구성된 배터리 에너지저장용 계통연계형 전력변환장치)

  • Park, Ah-Ryeon;Kim, Do-Hyun;Kim, Kyeong-Tae;Han, Byung-Moon;Lee, Jun-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.12
    • /
    • pp.1848-1856
    • /
    • 2012
  • This paper proposes a new grid-tied power conditioning system for battery energy storage, which is composed of a 2-stage DC-DC converter and a PWM inverter. The 2-stage DC-DC converter is composed of an LLC resonant converter connected in cascade with a 2-quadrant hybrid-switching chopper. The LLC resonant converter operates in constant duty ratio, while the 2-quadrant hybrid-switching chopper operates in variable duty ratio for voltage regulation. The operation of proposed system was verified through theoretical analysis and computer simulations. Based on computer simulations, a hardware prototype was built and tested to confirm the technical feasibility of proposed system. The proposed system could have relatively higher efficiency and smaller size than the existing system.

An Investigation of the Effect of Diesel Particulate Filter for Heavy-duty Diesel Engine on Emission Reduction (디젤입자상물질 여과장치의 배기저감성능 효과 분석)

  • Park, Yong-Hee;Shin, Dae-Yewn
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.1 s.94
    • /
    • pp.36-42
    • /
    • 2007
  • Diesel PM can be controlled using Diesel Particulate Filter, which can effectively reduce the level of soot emissions to ambient background levels. In the Heavy Duty Diesel area, the Continuously Regeneration trap has been widely applied in the retrofit market. As the Special act for the improvement of air quality in the capital area, the retrofit program for DPF to used diesel vehicle has progressed favorably and there are currently over 1,000 of these DPF in use in retrofit applications in korea. These DPF comprise a specially formulated Diesel Oxidation Catalyst upstream of a DPF. The $NO_2$ generated by the DOC is used to combust the carbon collected in the DPF at low temperature. To certificate DPF device that is suitable to domestic circumstances, it is necessary to evaluate exactly the DPF devices according to the regulation of DPF certificate test procedure for retrofit(ministry of environment(MOE) announcement NO. 2005-16). To do so the understand of that regulation like the standard of PM reduction rate is needed. In this study the test procedure including test cycle and BPT test condition was examined and also the test result for specific DPF was analyzed. In every test like field test, PM reduction efficiency test and seoul-10 mode test, no defect could be showed.

The Study of fabrication and characteristics of Inorganic EL Device with combination of high dielectric constant layer (고유전 유전막을 적용한 Inorganic EL Device 제작 및 특성 연구)

  • Lee, Gun-Sub;Ryu, Ji-Ho;An, Sung-Il;Lee, Seong-Eui
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.392-393
    • /
    • 2007
  • In this paper, we report the characteristics inorganic EL device with high dielectric constant materials of PMN, PZT. Fabricated EL device shows stable light emission even at 20kHz -400Volt without any break down failure. Brightness voltage curve of EL device is same with typical EL. As increasing applied voltage, the brightness increased linearly. From the results of Frequency and duty ratio variation, over 50% of brightness increment was seen. Luminous efficiency was increased upto 200V range and saturated over 200V by slow increasement of light emission. We got e bright stable emission of 1733 cd/m2 at the condition of Frequency 35 KHz, Duty 10%, 400V.

  • PDF

Design, Analysis and Evaluation of A New Energy Conserving MAC Protocol for Wireless Sensor Networks

  • Lim, Sangsoon;Kang, Young-Myoung;Jeong, Jiwoong;Kim, Chong-Kwon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3046-3060
    • /
    • 2012
  • Low power listening (LPL) MAC protocols based on duty-cycling mechanism have been studied extensively to achieve ultra low energy consumption in wireless sensor networks (WSNs). Especially, recent ACK-based LPL schemes such as X-MAC employ strobe preambles and an early ACK, and show fair performances in communications and energy efficiencies. However, the state-of-the-art ACK-based LPL scheme still suffers from collision problems due to the protocol incompleteness. These collision effects are not trivial and make WSNs unstable, aggravate energy consumptions. In this paper, we propose two novel schemes; (i) ${\tau}$-duration CCA to mitigate the collision problem in ACK-based LPL MAC protocols. (ii) Short Preamble Counter (SPC) to conserve more energy by reducing unnecessary overhearing. We demonstrate the performance improvement of our scheme via a mathematical analysis and real-time experiments. Both analysis and experimental results confirm that our proposed scheme saves energy by up to 36% compared to the naive ACK-based LPL MAC protocol thanks to ${\tau}$-duration CCA and SPC.

Work Stress and Affecting Factors of Emergency Medical Technicians (응급구조사의 업무 스트레스와 그 영향 요인)

  • Jo, Hyeon Tae
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.15 no.3
    • /
    • pp.95-103
    • /
    • 2014
  • Objectives: To identify work stress and affecting factors of the emergency medical technicians(EMT) and to provide basic data for work circumstance improvement and emergency medical service and duty efficiency elevation. Methods: The data were collected by questionnaire from 635 emergency medical technicians throughout the whole country from August 5 to September 20 2013 and analyzed by using the SPSS(version 18.0) program. Factors affecting stress were analyzed by Multiple Linear Regression Analysis(${\alpha}=0.05$). Results: Mean level of job stress was markedly high in the spot situation(3.43 point), user awareness(3.31 point), burden related to work(3.21 point), role and conflict as a professional job(3.10 point), unsuitable treatment(2.95 point) but was lowest in specialty demand of knowledge and skill(2.76 point). Conclusions: To diminish work stress, understanding and cooperation of the residents and reduction of burden related to work must be improved. Above all, positive interest of 119 and related organ and duty environment improvement will and effort and continuous measure establishment and support and cooperation of the government are needed.

  • PDF