• Title/Summary/Keyword: dual-feeding

Search Result 114, Processing Time 0.029 seconds

Design of a Dual-fed Microstrip Patch Antenna (이중급전 마이크로스트립 패치 안테나 설계)

  • Lee, Jong-Ig;Yeo, Junho;Kim, Gun-kyun;Rhee, Seung-Yeop
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.79-80
    • /
    • 2016
  • In this paper, we considered a design method for a microstrip patch antenna fed through two radiating edges by two feeding microstrip lines. Two feedlines are made to have a phase difference of 180 degree with each other in order to reduce cross-polarization level radiated from the antenna. The operation principle and design procedure for the considered antenna are explained using equivalent circuits. In order to check the validity of this study, the results for reflection coefficients of the antenna obtained by the proposed equivalent circuit method and the simulation using commercial antenna design tool are compared with each other.

  • PDF

Citric Acid Production and Scale-up in Dual Hollow Fiber Bioreactor (이중실관 생물 반응기에서의 구연산 생산과 Scale-up)

  • 장호남;지동진;심상준
    • Membrane Journal
    • /
    • v.2 no.2
    • /
    • pp.122-128
    • /
    • 1992
  • A study on the citric acid production was performed in various size dual hollow fiber bioreactors with immobilized Aspergillus niger (KCTC 1232). The final dry cell mass density reached 300g/l based on the space volume available for cell growth. Under air and oxygen aeration the volumethe productivity reached 0.63 and 1.02g/l.h, which cormsponded to 10 and 16 fold over those of batch fermentation, respectively. The initial pH of the medium was a critical factor and the lower value resulted in higher citric acid yield. The increase in the feeding rate of medium or the number of reactor unit resulted in the improvement of the productivity due to higher consumption rate of substrate.

  • PDF

A Study on the Design of Dual­Band Equilateral­Triangular Microstrip Antennas (듀얼­밴드 정삼각형 마이크로스트립 안테나 설계에 관한 연구)

  • 문정군;이종철;황호순;이문수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1604-1611
    • /
    • 2003
  • For dual­band operation, it can be done by loading two pair of slits in the equilateral­triangular patch, one embeded close to the side edges of the patch and the other inserted at the bottom edge of the patch. The frequency ratio of the two operating frequencies can be tuned by varing the positions and lengths of the inserted slots at the bottom edge of the patch. While the calculated frequency ratio of the antenna by Ensemble 5.0 is $1.66 ({f_10}=1.928GHz, {f_20}=3.2GHz)$, the measured one is 2.04 $({f_10}=1.6806 GHz, {f_20}=3.435 GHz)$. The error in the frequency ratio is due on the fabrication dimension and feeding position error as well as on the permittivity dispersion effect.

A Wide Band Antenna Design using the Synthesis of Independent Dual Resonance Modes for Manpack SDR(Software Defined Radio) (독립적인 이중 공진 모드 합성을 이용한 광대역 SDR 무전기 안테나 설계)

  • Yu, Byunggil;Dong, Moo-Ho;Cho, Ji-Haeng;Han, Sung-Woo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.57-63
    • /
    • 2014
  • In this paper, we have proposed a wide band antenna for manpack SDR(Software Defined Radio). The proposed antenna consists of feeding post, flexible gooseneck and two radiating elements composed of a upper and lower radiators. The upper radiator has a longer electrical length than the lower radiator in order to operate in the lower frequency. Also, the resonant frequency and impedance characteristics of the antenna can be adjusted independently for two radiators. Therefore, the proposed antenna can be achieved wide impedance bandwidth by the combination of two independent resonance modes. To analyze the characteristics of the antenna in the design process is employed the equivalent circuit theory and EM(Electro-Magnetic) simulation. The measurement results show that the proposed antenna have the sufficient wide bandwidth, above -3.4dBi of the gain and fairly good radiation pattern over the wide bandwidth.

Design and Fabrication of Miniaturized Dual-bandpass filter Using Rectangular ring resonator and Interdigital capacitive feeding-structure (Rectangular Ring 공진기와 Interdigital Capacitive 급전구조를 이용한 소형화된 이중대역통과필터의 설계 및 제작)

  • Yoon, Hyun-Soo;Kang, Sang-Rok;Choi, Byoung-Ha
    • Journal of Navigation and Port Research
    • /
    • v.31 no.5 s.121
    • /
    • pp.415-420
    • /
    • 2007
  • In this paper, we have designed and fabricated a new type of bandpass-filter that used rectangular ring and interdigital capacitive feeding-structure. The filter is applied the modified rectangular ring and interdigital capacitive feeding-structure in patch, which reduce rho size of filter and IEEE 802. 11 correspond to wireless LAN domain(2.45GHz and 5.2GHz) for operating. As a result, the design and fabrication process of the filter become simple and the size of it is reduced more than 60% compared with RF filter are available conventional PEMBF(Parallel Edge-coupled Microstrip Bandpass Filter) of accounted circuit by minimum stage, measurement result of fabricated filter, center frequence is down 2.408GHz and 5.075GHz. input return loss is -39.169dB at 2.408GHz, -40.922dB at 5.075GHz. insertion loss is -0.437dB at 2.408GHz, -1.669dB at 5.075GHz.

Design and Fabrication of Dual Linear Polarization Antenna for 28 GHz Band (28 GHz 대역에서 동작하는 이중 선형편파 안테나의 설계 및 제작)

  • Yoon, Joong-Han
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.1
    • /
    • pp.13-22
    • /
    • 2022
  • In this paper, we propose single and array antenna with dual linear polarization characteristics for 28 GHz band. The proposed antenna is designed two microstirp feeding structure and Taconic TLY-5 substrate, which is thickness 0.5 mm, and the dielectric constant is 2.2. The size of single patch antenna is 3.4 mm×3.4 mm, and total size of single antenna is 15.11 mm×15.11 mm. Also, the size of array antenna is 3.15 mm×3.15 mm, and total size of array antenna is 21.5 mm×13.97 mm. From the fabrication and measurement results, for 1×2 array antenna, in case of vertical polarization, cross polarization ratios are obtained from 14.23 dB to 20.79 dB and in case of horizontal polarization, cross polarization ratios are obtained from 14.31 dB to 22.74 dB for input port 1. in case of vertical polarization, cross polarization ratios are obtained from 15.75 dB to 25.88 dB and in case of horizontal polarization, cross polarization ratios are obtained from 14.70 dB to 22.82 dB for input port 2.

Design and Fabrication of Dual Linear Polarization Antenna for mmWave Application using FR-4 Substrate

  • Choi, Tea-Il;Yoon, Joong-Han
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.3
    • /
    • pp.71-77
    • /
    • 2022
  • In this paper, we propose 1×2 array antenna with dual linear polarization characteristics for mmWave band operation. The proposed antenna is designed two microstirp feeding structure and FR-4 substrate, which is thickness 0.4 mm, and the dielectric constant is 4.3. The size of 1×2 array antenna is 2.33 mm×2.33 mm, and total size of array antenna is 13.0 mm×6.90 mm. From the fabrication and measurement results, bandwidths of 1.13 GHz (28.52~29.65 GHz) for port 1 and 1.08 GHz (28.45~29.53 GHz) for port 2 were obtained based on the impedance bandwidth. Cross polarization ratios are obtained from 7.68 dBi to 16.90 dBi in case of vertical polarization, and from 7.46 dBi to 15.97 dBi in case of horizontal polarization for input port 1, respectively. Also, cross polarization ratios are obtained from 8.59 dBi to 13.72 dBi in case of vertical polarization and from 9.03 dB to 14.0 dB in case of horizontal polarization for input port 2, respectively.

Anemia and Iron Deficiency according to Feeding Practices in Infants Aged 6 to 24 Months

  • 김순기
    • Journal of Nutrition and Health
    • /
    • v.31 no.1
    • /
    • pp.96-101
    • /
    • 1998
  • The prevalence of iron deficiency in later infancy and the toddler years(25% to 40% at 1 year of age) has not decreased remarkably , except in Western countries. The purpose of this study was to 1) determine the relationship between current feeding practices and iron status, and 2) assess compliance to infant feeding instructions. Two groupsof infants were examined. The first group of 302 infants aged 6 to 24months was seen at a well baby clinic while the second group of 135 infants of the same age group was assessed by venipuncture. Cutoff values for laboratory tests were as follows ; hemoglobin<11g/dL, mean corpuscular volume (MCV) <72fl ; red cell distribution width(RDW)>15% ; serum ferritin level<10ng/ml ; and transferrin saturation (serum iron(TIBC)<10%. The diagnosis of iron deficiency anemia (IDA) was made when a low hemoglobin level was associated with either low ferritin orlow transferrin saturation . Of the 302 children brought to the well baby clinic , 12.3%(n=37) were found to have anemia (hemoglobin<11.0/dL). In terms of children grouped according to feeding practices, it was found that children with anemial comprised 32.0% (24/75) of the prolonged breast-fed group (Group A), significantly more than the 4.0%(7/176) of the artificial milk feeding group(Group B). and 3.9%(2/51) of the switched from breast milk to iron -fortified weaning foods group(Group C).Among the 107 children with IDA , iron deficiency in 105 children(98.1%) was suggested by their dietary histories ; exclusive or prolonged breast-feeding for more than 6 months without iron fortification in 98 infants ; cow's milk consumption> 500ml/day without iron fortification during infancy(n=12), or >800ml without iron-fortified foods after infancy(n=15) ; and the use of unfortified forumula or unbalanced diets, mainly limited to rice gruel. Despite the relatively high (79.6%) motivation on the part of the infants mothers and supervison by professional personnel, the poor results in the infants receiving iron fortified foods were due to poor compliance(85.75). Among the mothers of 98 IDA patients who were contacted by telephone , it was revealed that 29% did not give the oral iron preparation for more than 2 months. Furthermore, negligence or disregard by the parents occurred in 14% of the case , discontinuance of the oral iron preparation by the parents due to side effects occurred in 6%, and the children's refusal or poor oral intake and no further trial occurred in 6%. The dietary history of a large group of infants was highly predictive of their risk for anemia . Continued consumption of breast milk until the age of 1 year is not warranted unless iron-fortified foods are given concomitantly. Because there is a problem with compliance, more successful and safe strategies for preventing iron deficiency woold included dual coverage in the from of therapeutic iron supplementation as well use of iron-fortified foods for teddlers who are at risk of iron deficiency.

  • PDF

Dual Band Microstrip Antenna with Modified Inset Feeder and a Slot (수정된 Inset 급전선과 단일 슬롯을 이용한 이중대역 마이크로스트립 안테나)

  • Rhee, Seung-Yeop
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.9
    • /
    • pp.800-807
    • /
    • 2016
  • In this paper, we study the characteristics of dual band microstip antenna with modified inset feeder and a single slot. The modified inset feeder consists of the vertical inset feeder placed in x direction and the horizontal one in y direction for shortening the total length of inset feeder. The optimun feeding position for good impedance matching at two resonant frequencies can be easily found by adjusting the horizontal inset distance. And Various frequency ratios can be simply obtained by the parameters of slot. The measurements for fabricated antenna prototypes are carried out for validation. The measured results show a tunable frequency ratio from 1.25 to 1.88 with the variation of slot parameters. It is worthwhile to point out that the radiation patterns are similar at both bands. and below -20.0 dB of cross polarization level at the E plane.

Effect of Swirl Angle on the Atomization Characteristics in Two-Fluid Nozzle with Dual Air Supplying System (이중공기공급 이유체노즐의 선회각 변화에 따른 분무특성)

  • Kim, E.S.;Kang, S.M.;Choi, Y.J.;Kim, D.J.;Lee, J.K.;Rho, B.J.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.54-60
    • /
    • 2008
  • The atomization characteristics of the dual air supplying twin-fluid nozzle were investigated experimentally using PIV and PDA systems. The two-fluid nozzle is composed of three main parts: the feeding injector to supply fluid that is controlled by a PWM (pulse-width modulation) mode, the adaptor as a device with the ports for supplying the carrier and assist air and the main nozzle to produce the spray. The main nozzle has the swirl tip with four equally spaced tangential slots, which give the injecting fluid an angular momentum. The angle of the swirl tip varied with 0$^{\circ}$ 30$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$, and the ratios of carrier air to assist air and ALR(total air to liquid) were 0.55 and 1.23, respectively. The macroscopic behavior of the spray was investigated using PIV system, and the mean velocity, turbulent intensity and SMD distributions of the sprays were measured using PDA system. As the results, the mean axial velocity at the spray centerline decrease with the increase of the swirl angle. The turbulent intensities of the axial and radial velocity were increased with the increase of the swirl angle. The mean SMD (Sauter mean diameter) of the radial direction along the axial distance shows the lowest value at the swirl angle of 60$^{\circ}$.

  • PDF