• Title/Summary/Keyword: dual sensing

Search Result 150, Processing Time 0.027 seconds

Successful Removal of 15-year-old Pacemaker Leads by Weight and pulley method

  • Kim, Hyun-Woo;Shin, Ho-Cheol;Jin, Han-Young;Seo, Jeong-Sook;Jang, Jae-Sik;Yang, Tae-Hyun;Kim, Dae-Kyeong;Kim, Dong-Soo
    • Kosin Medical Journal
    • /
    • v.33 no.3
    • /
    • pp.396-401
    • /
    • 2018
  • Extraction of old pacemaker leads remains a complex procedure owing to fibrotic encapsulation and lead adhesions. We report a case of extraction of 15-year-old pacemaker leads by weight and pulley method. A 81-year-old man presented with exposed pacemaker leads out of body with purulent discharge from a pacemaker insertion site. He inserted DDD (dual chamber pacing, dual chamber sensing dual function) pacemaker implantation 15 years ago for SSS. Previously pacemaker battery was removed 3 years ago due to recurrent infection of pacemaker scar site. We extracted the pacemaker leads by weight and pulley method successfully without any complications.

Location of pressure sensing holes in MPA flowmeter and discharge coefficients (MPA 유량계 압력감지공의 위치와 유출계수)

  • Kim, Raymond K.;Choi, Sung Kil
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.160-165
    • /
    • 2004
  • MPA (Multi-Point Averaging) flow element is a new type of differential pressure (DP) flow-sensing device that was developed by Seojin Instech to improve the operating characteristics of the conventional Averaging Pilot Tube (APT) flow elements. Operating characteristics of a flowmeter in general can be defined in terms of measurement accuracy and range. Improvement of accuracy and expanding the range of flow measurement were the two main objectives of the development. To achieve these dual objectives several upstream and downstream pressure-sensing holes were placed in MPA flow element. During the course of the development it was found that certain arrangements of the pressure-sensing holes improved measurement accuracy but did not expand operating flow range of Averaging Pilot Tubes. Development tests were performed with water between Reynolds number of 50,000 and 1,000,000 in the four-inch test line at the Alden Research Laboratory, U.S.A. Purpose of this paper is to present the relationship between the various locations of the pressure-sensing holes and the performance characteristics of MPA flow element. Furthermore, the operating characteristics of the best performing MPA are compared with those of typical orifice and APT.

  • PDF

Development of the A/D Conversion Module and Communication for Remote Sensing Use. (원격 센싱용 A/D 변환 모듈과 그 통신 프로그램의 개발)

  • Park, C.W.;An, K.H.;Kang, H.G.;Choi, G.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1313-1315
    • /
    • 1996
  • This paper presents a new method to obtain more stable and precise A/D conversion for remote sensing use. Hardware is designed to compensate offset voltage and drift & temperature characteristics, as well as to perform dual slop A/D converter by using single chip microprocessor. Serial communication program which is based on ASCII code commands is also developed to add initial setup & calibration functions as well as to perform A/D data communication. Proposed method will give a good applications to the industrial field where a high precision remote sensing is required.

  • PDF

Low-Power 512-Bit EEPROM Designed for UHF RFID Tag Chip

  • Lee, Jae-Hyung;Kim, Ji-Hong;Lim, Gyu-Ho;Kim, Tae-Hoon;Lee, Jung-Hwan;Park, Kyung-Hwan;Park, Mu-Hun;Ha, Pan-Bong;Kim, Young-Hee
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.347-354
    • /
    • 2008
  • In this paper, the design of a low-power 512-bit synchronous EEPROM for a passive UHF RFID tag chip is presented. We apply low-power schemes, such as dual power supply voltage (VDD=1.5 V and VDDP=2.5 V), clocked inverter sensing, voltage-up converter, I/O interface, and Dickson charge pump using Schottky diode. An EEPROM is fabricated with the 0.25 ${\mu}m$ EEPROM process. Power dissipation is 32.78 ${\mu}W$ in the read cycle and 78.05 ${\mu}W$ in the write cycle. The layout size is 449.3 ${\mu}m$ ${\times}$ 480.67 ${\mu}m$.

  • PDF

A new, hybrid, heterodyne, fiber-optic electric field sensor scheme and its applications (I/Q 변조 풀이 방식의 헤테로다인 간섭계를 이용한 미소 전기장 및 복굴절 측정)

  • 윤신영;조규만;이용산
    • Korean Journal of Optics and Photonics
    • /
    • v.8 no.2
    • /
    • pp.161-164
    • /
    • 1997
  • A new hybrid, heterodyne, fiber-optic electric field sensor scheme is presented. In this scheme, a dual polarization, dual frequency, stabilized He-Ne laser is used for the light source of the interferometer, Probe beam is delivered to the sensor head using polarization maintaining fiber. In the sensor head, $LiTaO_3$ electro-optic crystal is used for sensing element. Phase retardation is induced on the dual frquency, dual polarization probe beam due to applied electric field across the crystal. Induced phase retardation is demodulated by in-phase and quadrature demodulation technique. In this way, we can obtain optimum sensitivity for electric field measurement regardless a quasi-static phase difference between two polarization components.

  • PDF

Sea fog detection near Korea peninsula by using GMS-5 Satellite Data(A case study)

  • Chung, Hyo-Sang;Hwang, Byong-Jun;Kim, Young-Haw;Son, Eun-Ha
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.214-218
    • /
    • 1999
  • The aim of our study is to develop new algorism for sea fog detection by using Geostational Meteorological Satellite-5(GMS-5) and suggest the techniques of its continuous detection. So as to detect daytime sea fog/stratus(00UTC, May 10, 1999), visible accumulated histogram method and surface albedo method are used. The characteristic value during daytime showed A(min) > 20% and DA < 10% when visble accumulated histogram method was applied. And the sea fog region which detected is of similarity in composite image and surface albedo method. In case of nighttime sea fog(18UTC, May 10, 1999), infrared accumulated histogram method and maximum brightness temperature method are used, respectively. Maximum brightness temperature method(T_max method) detected sea fog better than IR accumulated histogram method. In case of T_max method, when infrared value is larger than T_max, fog is detected, where T_max is an unique value, maximum infrared value in each pixel during one month. Then T_max is beneath 700hpa temperature of GDAPS(Global Data Assimilation and Prediction System). Sea fog region which detected by T_max method was similar to the result of National Oceanic and Atmosheric Administration/Advanced Very High Resolution Radiometer (NOAA/AVHRR) DCD(Dual Channel Difference). But inland visibility and relative humidity didn't always agreed well.

  • PDF

Characterization of Double-layer Optical Sensing Membranes for Dual Sensing of Dissolved Oxygen Concentrations and pH and Their Application to the On-line Monitoring of Fermentation Processes (용존산소농도와 pH의 동시 검출용 이중층 광학 센서막의 특성 및 발효공정의 온라인 모니터링에의 응용)

  • Kim, Chun-Kwang;Lee, Jong-Il
    • Applied Chemistry for Engineering
    • /
    • v.20 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • A double-layer optical sensing membrane has been fabricated to measure the concentration of dissolved oxygen (DO) and pH value simultaneously. (tris(4,7-diphenyl-1,10-phenanthroline (Rudpp) ruthenium(II)) as a DO sensitive dye has been mixed in the methyl trimethoxy silane (MTMS) sol-gel solution and coated onto one well in a 24-well microtiter plate. On the DO-sensing layer the GA (3-glycidoxypropyl trimethoxy silane (GPTMS), 3-aminopropyl trimethoxy silane (APTMS)) sol-gel solution mixed with 8-hydroxypyrene-1,3,6-trisulfonic acid trisodium salt (HPTS) has been coated and used to measure pH values. The double-layer sensing membrane was affected by ionic strength and temperature. The double-layer sensing membrane for DO and pH has been applied to online monitor in microorganism cultivation processes and showed a good performance.

Spatially Scalable Kronecker Compressive Sensing of Still Images (공간 스케일러블 Kronecker 정지영상 압축 센싱)

  • Nguyen, Canh Thuong;Jeon, Byeungwoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.10
    • /
    • pp.118-128
    • /
    • 2015
  • Compressive sensing (CS) has to face with two challenges of computational complexity reconstruction and low coding efficiency. As a solution, this paper presents a novel spatially scalable Kronecker two layer compressive sensing framework which facilitates reconstruction up to three spatial resolutions as well as much improved CS coding performance. We propose a dual-resolution sensing matrix based on the quincunx sampling grid which is applied to the base layer. This sensing matrix can provide a fast-preview of low resolution image at encoder side which is utilized for predictive coding. The enhancement layer is encoded as the residual measurement between the acquired measurement and predicted measurement data. The low resolution reconstruction is obtained from the base layer only while the high resolution image is jointly reconstructed using both two layers. Experimental results validate that the proposed scheme outperforms both conventional single layer and previous multi-resolution schemes especially at high bitrate like 2.0 bpp by 5.75dB and 5.05dB PSNR gain on average, respectively.

A Design of Multi-Channel Capacitive Touch Sensing ASIC for SoC Applications in 0.18 ${\mu}m$ CMOS Process (0.18 ${\mu}m$ CMOS 공정을 이용한 SoC용 정전 용량형 멀티 채널 터치 센싱 ASIC의 설계)

  • Nam, Chul;Pu, Young-Gun;Park, Joon-Sung;Hong, Seong-Hwa;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.4
    • /
    • pp.26-33
    • /
    • 2010
  • This paper presents a multi-channel capacitive touch sensing unit for SoC applications. This unit includes a simple common processing unit and switch array to detect the touch sensing input by capacitive-time(C-T) conversion method. This touch sensor ASIC is designed based on the Capacitive-Time(C-T) conversion method to have advantages of small current and chip area, and the minimum resolution of the unit is 41 fF per count with the built-in sensing oscillator, LDO regulator and $I^2C$ for no additional external components. This unit is implemented in 0.18 um CMOS process with dual supply voltage of 1.8 V and 3.3 V. The total power consumption of the unit is 60 uA and the area is 0.26 $mm^2$.

Concrete structural health monitoring using piezoceramic-based wireless sensor networks

  • Li, Peng;Gu, Haichang;Song, Gangbing;Zheng, Rong;Mo, Y.L.
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.731-748
    • /
    • 2010
  • Impact detection and health monitoring are very important tasks for civil infrastructures, such as bridges. Piezoceramic based transducers are widely researched for these tasks due to the piezoceramic material's inherent advantages of dual sensing and actuation ability, which enables the active sensing method for structural health monitoring with a network of piezoceramic transducers. Wireless sensor networks, which are easy for deployment, have great potential in health monitoring systems for large civil infrastructures to identify early-age damages. However, most commercial wireless sensor networks are general purpose and may not be optimized for a network of piezoceramic based transducers. Wireless networks of piezoceramic transducers for active sensing have special requirements, such as relatively high sampling rate (at a few-thousand Hz), incorporation of an amplifier for the piezoceramic element for actuation, and low energy consumption for actuation. In this paper, a wireless network is specially designed for piezoceramic transducers to implement impact detection and active sensing for structural health monitoring. A power efficient embedded system is designed to form the wireless sensor network that is capable of high sampling rate. A 32 bit RISC wireless microcontroller is chosen as the main processor. Detailed design of the hardware system and software system of the wireless sensor network is presented in this paper. To verify the functionality of the wireless sensor network, it is deployed on a two-story concrete frame with embedded piezoceramic transducers, and the active sensing property of piezoceramic material is used to detect the damage in the structure. Experimental results show that the wireless sensor network can effectively implement active sensing and impact detection with high sampling rate while maintaining low power consumption by performing offline data processing and minimizing wireless communication.