• Title/Summary/Keyword: dry test

Search Result 1,843, Processing Time 0.033 seconds

Computation of Unsteady Aerodynamic Forces in the Time Domain for GVT-based Ground Flutter Test (지상 플러터 실험을 위한 시간 영역에서의 비정상 공기력 계산)

  • Lee, Juyeon;Kim, Jonghwan;Bae, Jaesung
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.1
    • /
    • pp.29-34
    • /
    • 2016
  • Flutter wind-tunnel test is an expensive and complicated process. Also, the test model may has discrepancy in the structural characteristics when compared to those of the real model. "Dry Wind-Tunnel" (DWT) is an innovative testing system which consists of the ground vibration test (GVT) hardware system and software which computationally can be operated and feedback in real-time to yield rapidly the unsteady aerodynamic forces. In this paper, we study on the aerodynamic forces of DWT system to feedback in time domain. The aerodynamic forces in the reduced-frequency domain are approximated by Minimum-state approximation. And we present a state-space equation of the aerodynamic forces. With the two simulation model, we compare the results of the flutter analysis.

Thermographic Assessment in Dry Eye Syndrome, Compared with Normal Eyes by Using Thermography (열화상카메라를 이용한 정상안과 건성안의 서모그래피 비교)

  • Park, Chang Won;Lee, Ok Jin;Lee, Seung Won
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.247-253
    • /
    • 2015
  • Purpose: The purpose of this study was to compare and analyze the ocular surface and the palpebral conjunctiva of categorized subjects, which were divided into normal eye group and dry eye group, by using a thermal camera. Methods: Subjects were 144 eyes of 72 normal university students, who didn't have any corneal disease, abnormal lacrimal ducts, medical records regarding ocular surgeries, or experience of using contact lens. Subjects were divided into two groups, which were normal eye group and dry eye group, based on the results of TBUT, Schirmer I test, and McMonnies test. After categorizing the subjects, the temperature of the subjects' ocular surface and the palpebral conjunctiva were measured and analyzed by using a thermal camera (Cox CX series, Answer co., Korea). Results: In the normal eye group's Central Ar.1, Nasal Ar.2, Temporal Ar.3, Superior Ar.4, Inferior Ar.5, the measured amount of temperature change on each area was $-0.13{\pm}0.08$, $-0.14{\pm}0.08$, $-0.12{\pm}0.08$, $-0.14{\pm}0.08$, $-0.10{\pm}0.09(^{\circ}C/sec)$. The dry eye group's results were $-0.17{\pm}0.08$, $-0.16{\pm}0.07$, $-0.16{\pm}0.08$, $-0.17{\pm}0.09$, $-0.15{\pm}0.08(^{\circ}C/sec)$. When compared with the normal eye group, the values of Ar.1, Ar.3, Ar.5 were significantly different in the dry eye group(p<0.05). The amount of temperature change, which was observed on the palpebral conjunctiva(Ar.1:central, Ar.2: nasal, Ar.3: temporal) of the normal eyes, measured by thermography, was $34.36{\pm}1.12$, $34.17{\pm}1.10$, $34.07{\pm}1.12^{\circ}C$ on each area. Same values taken from the dry eye group was $33.55{\pm}0.94$, $33.43{\pm}0.97$, $33.51{\pm}1.06^{\circ}C$ on each area. The values of Ar.1, taken from the dry eye group, had a significant difference, compared to the values of the normal eye group(p=0.05). Conclusion: The temperature of the ocular surface decreased faster on the dry eyes, compared to the normal eyes. The temperature measured on the palpebral conjunctiva of the dry eyes were also lower than the normal eyes. The temperature changes on the ocular surface, observed with a thermal camera, were objective values to assess the stability of tear films, and might provide useful data for studies related to dry eye syndrome.

The Quality Characteristics of Rice-Mugwortbreads (건식 및 습식 쌀가루에 쑥가루를 첨가한 쑥쌀빵의 품질 특성)

  • 김영인;한경선
    • The Korean Journal of Community Living Science
    • /
    • v.11 no.1
    • /
    • pp.1-8
    • /
    • 2000
  • The characteristics of rice-breads with wet-milling and dry-milling rice-flours were investigated. Rice-breads by wet-milling had a good fermentation than the breads by dry-milling. Also, the fermentation of mugwort rice-breads was lower than those. Rice-breads by dry-milling indicated the higher value in hardness and the lower value in springiness, cohesiveness and chewiness than rice-breads by wet-milling. Also, mugwort rice-breads was the higher value in hardness, springiness, chewiness and the lower value in cohesiveness than rice breads. The test of the sensory characteristics for rice-breads showed that moistness, springiness, chewiness was higher for rice-breads by wet-milling. The sensory characteristics of mugwort rice-breads were lower than those, of rice-breads except the chewiness. Overall quality of rice-breads by wet-milling was higher than that of rice-breads by dry-milling. The overall quality of mugwort rice breads was higher than that of rice-breads by wet-milling, but lower than that of rice-breads by dry-milling.

A Experimental Study for Developing of the Dry Double Floors Hydronic Ondol System (건식이중바닥온돌시스템 개발을 위한 실험적 연구)

  • Kim Nan-Haeng;Sohn Jang-Yeul
    • Journal of the Korean housing association
    • /
    • v.17 no.3
    • /
    • pp.1-7
    • /
    • 2006
  • The aim of the research was to evaluate the characteristics of thermal environment and thermal comfort in the Dry Double floors Hydronic Ondol System. Physical indoor thermal environments (the floor surface temperature, the vertical temperature, etc.) and skin temperature have especially been measured. Physical features conditions, sensation, thermal comfort, humidity sensation, comfort of body were investigated for the survey. As a result, (1) During the operation of the boiler (12 hour), the average indoor temperature is appeared to be $21.6^{\circ}C$. The floor surface temperature showed peak value of $31.4{\sim}40.6^{\circ}C$ after 8hours 30minutes after the start-point of the heating. The vertical difference of temperature was turned out to be not uniform. (2) While the skin temperature showed a narrow distribution of temperature in the Dry Double floors Hydronic Ondol system. (3) The response to thermal comfort which people felt was satisfactory, and most of them felt dry during the test.

A Comparison Analysis on Thermal Performance According to Shape of Steel Stud Applied to Steel House (스틸 하우스 적용 스틸 스터드의 형상에 따른 단열성능 비교 연구)

  • Jang, Cheol-Yong;Lee, Na-Eun;Um, Eun-Jung
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.241-245
    • /
    • 2009
  • The dry wall using steel stud is used to buildings in the inside and outside of the country because it has the merit that application is possible to various architecture. The purpose of this study is to measure thermal performance of dry wall which uses steel stud transformed one by using measurement equipment to decrease heat bridge of steel stud and ensure heat performance as dry wall. As a comparative performance test result, dry wall which uses steel stud transformed one has a performance enhancement compare with the dry wall using general steel stud.

  • PDF

A Study on distribution of Dry Eye and Diagnosis Methods (건성안의 분포와 진단 방법에 대한 연구)

  • Ryu, Geun Chang;Park, Hyun Ju;Kim, Jae Min;Lee, Seung A;Ra, Myung Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.91-98
    • /
    • 2000
  • To investigate the distribution of dry eye and to accept diagnosis methods of dry eye in ophthalmic shop, this study was performed on 81 persons(male : 49, female : 32). 1. We divided two group for diagnosing dry eye by dry eye screening questionnaire : one was dry eye symptom group(49.3%) and the other was non-dry eye symptom group(50.7%). 2. Non-invasive break-up time(NIBUT) which was measured by using Tear $scope^{(R)}$ (Killer. co)was longer than invasive break-up time(IBUT). 3. A blink rate in dry eye symptom group(10%) was measured lesser than 10 cycle/min, in non-dry eye symptom group(14.9%). 4. In shirmer test there were lesser than 10mm/5min in dry eye symptom group(67.5%), in non-dry eye symptom group(39%). 5. Cornea and conjunctival staining by rose bengal represented Mild 25%, medium 36.25%, extreme 38.75% in dry eye symptom group. Non-dry eye symptom group was showed Mild 19.51%, medium 14.63%, extreme 12.19%. 6. These results showed that the patient showed dry eye symptom in 3 items of eye examination was 22.5%, 4 items 25%, 5 items 30%, 6 items 15%.

  • PDF

Evaluation on the Electrical Properties of Outdoor Epoxy Resin Insulators under Accelerated Agings (가속열화에 따른 옥외용 epoxy 수지 애자의 전기적특성 평가)

  • Cho, H.G.;Kim, I.S.;Ahn, M.S.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1360-1363
    • /
    • 1994
  • Epoxy resin insulator have good electrical properties (high electric strength, high resistivity, low dielectric loss) in addition to high mechanical strength, small dimensions and design versatility. Polymer insulator, however, are subjected to aging processes, caused by the surrounding atmosphere, which may lead to degradation of their properties. This paper describes the results of a important study on the artificial pollution test, Weather-Ometer properties and rotating wheel dip test of high voltage different aging insulators which are the most important factors for outdoor uses. Also, the objects of this paper are to (a)result of insulator under dry(wet) flashover voltage, (b)artificial pollution test of salt spay, (c)Accelerated aging test of Weather-Ometer, (d) wet and dry flashover voltage under rotating wheel dip test.

  • PDF

EFFECT OF WETNESS ON THE ENAMEL BONDING (법랑질 접착에 대한 습윤 효과)

  • Ko, Keun-Ho;Cho, Young-Gon;Jin, Cheul-Hee;Yoo, Sang-Hoon;Kim, Jong-Uk;Park, Byung-Cheul;Ki, Young-Jae;Choi, Hee-Young;Kim, Jong-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.205-211
    • /
    • 2004
  • This study evaluated the microleakage and interfacial gap between enamel and composite resin under the dry and wet condition of the enamel surface. V shaped class 5 cavities were prepared on the occlusal portion of extracted human molars. Samples were divided into three groups:D group (air dry for 10-15s), BD group (blot dry with moist cotton pellet), and DR group (air dry for 10-15s and rewet with Aqua-Prep F for 20s), Cavities were filled using Aelitefil composite resin after applied One-Step. Microleakage was tested by 2% methylene blue dye solution and the data were statistically analysed by Kruskal-Wallis test and Mann-Whitney test. Also Enamel-resin interface was observed under SEM. Group BD showed statistically lower microleakage than group D (p < 0.05). but there was no statistically significant difference between group BD and DR (p > 0.05). At the enamel-resin interface, group D showed the gap of $2{\;}{\mu}m$ thickness, but group BD and DR showed close adaptation. In conclusion, the use of blot dry and rewetting agent (Aqua-Prep F) resulted in decreased microleakage and improved adhesion between enamel and resin when using One-Step.

Experiment Evaluation for the Heavy-weight Impact Sound of Dry Double-floor System - Effect of Rubber Hardness and Ceiling Structure - (건식이중바닥구조의 중량충격음에 대한 실험적 평가 - 지지구조 및 천장구조 구성에 따른 영향 -)

  • Yeon, Junoh;Kim, Kyoungwoo;Choi, Hyunjuong;Yang, Kwanseop;Kim, Kyungho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.34-40
    • /
    • 2013
  • The 1st assessment(performance test) was applied to assure the floor impact sound performance for developing the dry double-floor with the change of rubber hardness of the upper panel's support and the ceiling structure of the sub-floor. Depends on the change of the rubber hardness in sub-structure, the heavy-weight sound impact value is improved up to 3 dB, and the light-weight sound impact value is moved up to 21 dB, comparing with the bare-slab. Also, the improved value for the floor impact sound conjugating with the sub-floor's ceiling was 5 dB. Based on this result, the 2nd assessment(performance test) was made the state that the rubber hardness of the sub-floor support was ranged between 50 and 70 for considering the stability of walking patients. In addition to this process, the assessment was carried out with a variety of ceiling structure applied to the dry double-floor structure with the air flow system on the sub-floor's ceiling. The result for the 2nd assessment proved that TYPEII-3 had the better sound reduction performance in the heavy-weight impact sound test than other types, and also for the light-weight impact sound TYPEII-3 had the 29 dB sound reduction performance overall. Henceforth, based on the result the research for the sound reduction performance from the floor impact sound shall be ongoing process as well as the development of a double-dry floor and a sound reduction ceiling to suitable on the field.