• Title/Summary/Keyword: dry heat

Search Result 917, Processing Time 0.031 seconds

Sludge Drying Method Using Microwave Drying Device and Heat Transfer Medium Oil (마이크로웨이브와 열전매체유를 이용한 슬러지 건조방법)

  • Kim, Yong-Ryul;Son, Min-Il
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.367-373
    • /
    • 2011
  • This research is a basic researching process for producing solid fuel that mixing paper sludge and Heat Transfer Medium Oil. Under the presence of Heat Transfer Medium Oil, paper sludge is heated and dried with home appliance microwave for comparing drying efficiency and energy efficiency of different types of drying method. As a result, Heat Transfer Medium Oil and paper mixing case of drying method, OMD, is the most efficient way to shorten the time for evaporating moisture in the paper sludge. In addition, heat transfer effect and density is increased with adding Heat Transfer Medium Oil by microwave. Future more, OMD's energy cost for evaporating whole moisture is 78% cheaper than MD. Also, OMD process shows the best energy efficiency with comparing other process. Evaporation rate of paper sludge evaporation process with microwave is 11.66% increased by adding Heat Transfer Medium Oil 150g. Preheating Heat Transfer Medium Oil or improving different ways injecting Heat Transfer Medium Oil is a good way to increase a rate of initiative moisture evaporation process.

A Study on the Performance of Heat Exchanger for Closed Cooling Tower (밀폐식 냉각탑용 열교환기의 성능에 관한 연구)

  • Lee, Sang-Sik;Yoo, Seong-Yeon;Kim, Jin-Hyuck;Ahn, Young-Hwan;Park, Hyoung-Joon;Ryu, Hae-Sung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

Experimental study of air side pressure drop and heat transfer characteristics of wave and wave-slit fin-tube heat exchangers (웨이브 및 웨이브-슬릿 열전달촉진 휜-관 열교환기의 공기측 압력강하 및 열전달 특성에 관한 실험)

  • Yoon, Baek;Gil, Yong-Hyun;Park, Hyun-Yeon;Yoo, Guk-Chul;Kim, Young-Saeng
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.5
    • /
    • pp.589-599
    • /
    • 1998
  • Air side heat transfer and pressure drop for fin-tube heat exchanger with wave and wave-slit fins were measured for various fin spacings and number of tube rows. Outer diameter of the tube including fin collar is 10.07mm, and experiments were done with dry surface condition. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of the wave fin is 2mm. Experiments were conducted for 1, 2 and 3 rows and 3 different fin spacings, 1.3, 1.5 and 1.7mm. An attempt was made to demonstrate advantage of the enhanced fins over the plane fin by introducing the concept of fan power, Effect of the number of tube rows on heat transfer was discussed in connection with general mechanisms of heat transfer enhancement for fin-tube heat exchanger. Also the effect of hydrophilic coating was investigated. Lastly, correlations for Colburn j-factor and friction factor were developed.

  • PDF

Unsteady heat exchange at the dry spent nuclear fuel storage

  • Alyokhina, Svitlana;Kostikov, Andrii
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1457-1462
    • /
    • 2017
  • Unsteady thermal processes in storage containers with spent nuclear fuel were modeled. The daily fluctuations of outer ambient temperatures were taken into account. The modeling approach, which is based on the solving of conjugate and inverse heat transfer problems, was verified by comparison of measured and calculated temperatures in outer channels. The time delays in the reaching of maximal temperatures for each spent fuel assembly were calculated. Results of numerical investigations show that daily fluctuation of outer temperatures does not have a large influence on the maximal temperatures of stored spent fuel, so that fluctuation can be neglected and only daily average temperature should be considered for safety estimation using the "best estimation" approach.

Protection of Canola (Low Glucosinolate Rapeseed) Meal and Seed Protein from Ruminal Degradation - Review -

  • Mustafa, A.F.;McKinnon, J.J.;Christensen, D.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.13 no.4
    • /
    • pp.535-542
    • /
    • 2000
  • Canola meal and seed are poor sources of ruminal undegraded protein (RUP). On average, canola meal and canola seed contains 35 and 14% RUP, respectively. Several protection methods are effective in reducing ruminal degradation of canola protein and in increasing RUP without affecting total tract protein digestibility. Heat (e.g., dry heat, moist heat and jet-sploding) and chemical (e.g., formaldehyde) treatments are the most common methods used to reduce ruminal degradability of canola protein. In most cases, heat treatments were found to be more effective than chemical treatments in protecting canola protein form ruminal degradation. Despite improvement in RUP content and intestinal availability of RUP, data form several studies showed little or no improvement in animal performance as a result of increasing the RUDP level of canola meal and seed.

Development of Heat Transfer and Evaporation Correlations for the Turbulent Natural Convection in the Vertical Channel by Using Numerical Analysis

  • Kang, Han-Ok;Lee, Un-Chul
    • Nuclear Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.532-541
    • /
    • 1996
  • Theoretical and numerical study on heat transfer and evaporation in the vertical channel has been carried out and basic correlations have been derived for the heat transfer evaluation of PCCS. Analysis program was developed with low-Reynolds-number k-$\varepsilon$ model and surface transfer rates were calculated for the turbulent natural convection in the vertical channel. In relation to dry cooling by buoyancy-driven air, first, the system parameters which govern overall heat transfer rate are determined through the adequate nondimensionalization procedure. After comparison with existing experimental data, numerical results are used to derive heat transfer correlation by sensitivity calculations. In relation to wet cooling by falling water film, numerical analysis are carried out for evaporation process with real film surface conditions and evaporation correlation is derived through analogy concept and correction factors.

  • PDF

A Bibliographic Study on The Research of nosebleeding by damaged lung (상폐(傷肺)에 의(依)한 비출혈(鼻出血)의 문헌적(文獻的) 고찰(考察))

  • Kim, Sung-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.45-55
    • /
    • 1991
  • It has been known that the nosebleeding is a king hemorrhage occured to be damaged yang-rak (陽略) & lung. the results obtained were as follows; 1. The cause of nosebleeding were divided internal external, these were lung-heat(肺實熱), wind-heat(風熱), dry-heat(煥熱), wind-cold(風寒), summer-heat(暑熱), and those were transporting of Liver-fire(肝火犯肺), Liver-kidney-fire(肝腎陰虛熱傷肺), Stomach-fire(胃火熾盛), Heart-fire(心火千肺). 2. The treatment of external ; Chungpaesulyul(淸肺泄熱), Yanghyuljihyul(凉血止血), Sanpungchungyul(散風淸熱), Jaeumchungjo(滋陰淸煥). 3. The treatment of internal ; Chungkansahwa(淸肝瀉火), Yanghuljihyul(凉血止血), Jayumganghwa(滋陰降火), Chunguysahwa(淸胃瀉火). The cause of nosebleeding was almost heat (fire), and the treatment were Sanpyo(散表) & Chungri(淸裏).

  • PDF

Study on the Development of Diagnosis Algorithm of Soeumin Symptomology (소음인(少陰人) 병증(病證) 진단 알고리즘 개발 연구)

  • Shin, Seung-Won;Lee, Eui-Ju;Koh, Byung-Hee;Lee, Jun-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.23 no.1
    • /
    • pp.33-43
    • /
    • 2011
  • 1. Objectives: This study is aimed to develop the algorithm, which can help clinicians diagnose Soeumin's symptomology, based on the indexes such as dry mouth, water drinking, sweat, urine, appetite, digestion, and stool, etc. 2. Methods: This research analyzes the items of "Donguisusebowon(東醫壽世保元)" to reveal the inevitable and sequential indexes of Soeumin's symptomology diagnosis, in order of exterior-interior pattern differentiation, favorable-unfavorable pattern differentiation, and mild-severe-dangerous-urgent pattern differentiation. 3. Results and Conclusions: 1) 1st step: Soeumin's exterior pattern and interior pattern are differentiated in terms of heat and cold, respectively. Stool and digestion are used to confirm the difference. 2) 2nd step: The existence of sweat is used to find out that an exterior pattern is with or without favor, while the indexes of stool, dry mouth, and generalized pain are used to identify an interior pattern with or without favor. 3) 3rd step: The favorably exterior-heat pattern can be either mild or severe by the indexes of cold-heat, stool, tidal fever, and manic raving, panting and straight looking, while the unfavorably exterior-heat pattern can be either dangerous or urgent by the ones of cold-heat, stool, and urine. And, the favorably interior-cold pattern can be either mild or severe by the indexes of stuffiness and fullness, jaundice, and edema, while the unfavorably interior-cold pattern can be either mild or severe by the ones of vexation level.

Fundamental Evaluation and Hydration Heat Analysis of Low Heat Concrete with Premixed Cement (저발열형 Premixed Cement를 사용한 콘크리트의 기초물성 평가 및 수화열 해석에 관한 연구)

  • Yoon, Ji-Hyun;Jeon, Joong-Kyu;Jeon, Chan-Ki;Kim, Ki-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.10-18
    • /
    • 2014
  • This study carried out to evaluate the hydration heat analysis and fundamental characteristics such as air content, slump, compressive strength and dry shrinkage according to concrete with premixed cement, ternary concrete and OPC concrete for using concrete with premixed cement. The results of experiment are founded that concrete with premixed cement have sufficient performances such as workability, compressive strength and dry shrinkage. Also, the results of hydration heat analysis are founded that concrete with premixed cement have more performance than ternary concrete and OPC concrete at a point of view for the quality control such as thermal crack reducing and economic benefit. Therefore, it is desirable that concrete with premixed cement should be used to rise durability performance and convenience of maintenance.

Inhibitory Effect of Dry-Heat Treatment and Chemical Sanitizers against Foodborne Pathogens Contaminated on the Surfaces of Materials (재질 표면에 오염된 여러 병원성 세균에 대한 건열살균 및 살균소독제의 저해효과)

  • Bae, Young-Min;Heu, Sun-Gi;Lee, Sun-Young
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1265-1270
    • /
    • 2009
  • Pathogens contaminated on the surface of utensils could contribute to the occurrence of outbreaks due to cross-contamination to foods during the food preparation process. Therefore, the efficacy of chemical sanitizers (chlorine-based and alcohol-based commercial sanitizers) and dry-heat ($71^{\circ}C$) on inhibiting biofilms of five foodborne pathogens (Escherichia coli O157:H7, Salmonella Typhimurium, Pseudomonas aeruginosa, Listeria monocytogenes, and Staphylococcus aureus) on the surface of stainless steel and polypropylene were investigated in this study. Initial populations of pathogens were 8.8$\sim$9.3 and 9.4$\sim$10.3 log CFU/coupon on the surface of stainless steel and polypropylene coupon, respectively, and these populations were not significantly reduced when they were treated with water for 5 min at room temperature. Treatments with chlorine sanitizer and dry-heat were not effective on inactivating pathogens on the surfaces of stainless steel and polypropylene. In contrast, treatments with alcohol sanitizer were very effective on inactivating pathogens on the surfaced of stainless steel and polypropylene. Reduction levels ranged from 3.4 to 6.4 log and from 5.5 to 7.4 log CFU/coupon in stainless steel and plastic coupons, respectively. From these results, alcohol-based sanitizer could be used as a potential way for controlling microbial contamination on the surface of utensils, cooking equipment, and other related environments.