• Title/Summary/Keyword: dry eye tests

Search Result 11, Processing Time 0.035 seconds

A comparative study of contact lens wearer with dry-eye patient on tear function tests (콘텐트렌즈 착용자와 건성안 환자의 눈물 검사에 대한 비교 연구)

  • Kim, Soon-Ae;Seo, Eun-Sun;Lee, Young-Hwan;Kim, Ja-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.301-312
    • /
    • 2004
  • This study was performed to compare the relationship between contact lens wearer and dry-eye patient. In this study, TBUT, SIT, TTT, Rose bengal staining and McMonnies dry eye symptom questionnaire were performed as a baseline. With the base data, the subjects were classified to 3 groups : 3S patients who have dry eye signs and symptoms, 38 patients who are wearing soft contact tenses, 35 subjects who have health eyes and never worn on a contact lenses as control subjects. Contact lens wearers were divided into 3 groups according to the duration of contact lens wear. There were no significant differences in TBUT, STT, TTT, Rose-bengal staining and McMonnies dry eye symptom questionnaire result between contact lens wearer group and dry eye patients group. We suggest that there are similarities in tear function tests between the dry-eye patient and the contact lens wearer.

  • PDF

Development of Paper-based Microfluidic Device for Dry Eye Test (종이-미세유체공학을 이용한 건성안 검사 용지 개발)

  • Seo, Young Tae;Noh, Hyeran
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2013
  • Purpose: The aim of this study was to develop a dry eye test method using a paper based microfluidic device that improves inaccuracy caused by using one of current point-of-care dry eye tests such as Shirmer's. Methods: Wax printed hydrophilic chromatography papers were dyed with anthocyanin extracts to detect colorimetric display of liquid samples with varying pH. Fluid distribution rates were measured using artificial tears and human tears directly from 32 subjects. Results: With Shirmer's, fluid distribution rates with small amount of samples (less than $0.5{\mu}l$) were not displayed. However, with paper based microfluidic device, fluid imbibition distances over time were clearly showed. Also clinical results of dry eye from newly developed paper based microfluidic device showed correlation with the results from tear break up time tests. Conclusions: The newly developed paper based microfluidic devices were easy to use and exhibited more accurate clinical results than current dry eye point of care tests such as Shirmer's.

Reference values for selected dry eye tests in normal Beagle dogs: a pilot study

  • Kim, Youngsam;Kang, Seonmi;Kim, Sunhyo;Shim, Jaeho;Go, Seokmin;Seo, Kangmoon
    • Journal of Veterinary Science
    • /
    • v.23 no.1
    • /
    • pp.10.1-10.12
    • /
    • 2022
  • Background: Dry eye disease (DED) cannot be diagnosed by a single test because it is a multifactorial disorder of the ocular surface. Although studies on various dry eye tests (DETs) in dogs have been reported, standard criteria have not been established except for the Schirmer tear test 1 (STT-1). Objectives: To establish reference values for DETs in dogs with normal STT-1 values (≥ 15 mm/min) and to analyze the correlation between DETs. Methods: The STT-1 was performed in 10 healthy Beagle dogs (20 eyes). After 20 min, interferometry (IF) for estimating the lipid layer thickness (LLT) of the tear film, tear meniscus height (TMH), non-invasive tear breakup time (NIBUT), and meibomian gland loss rate of the upper eyelid (MGLRU) and lower eyelid (MGLRL), were measured using an ocular surface analyzer. Results: Mean values for STT-1, TMH, and NIBUT were as follows: 21.7 ± 3.4 mm/min, 0.41 ± 0.21 mm, and 19.1 ± 9.5 sec, respectively. The most frequent LLT range, measured by IF, was 30-80 nm (11 eyes), followed by 80 nm (5 eyes) and 80-140 nm (4 eyes). MGLRU ≤ 25% was measured in 11 eyes and 26%-50% in 9 eyes; MGLRL ≤ 25% in 8 eyes and 26%-50% in 12 eyes. Besides positive correlation between TMH and NIBUT (P = 0.038), there were no significant associations between DETs. Conclusions: Data obtained in this study provided normative references that could be useful for diagnosing DED and for further research into correlation between DETs in dogs with DED.

Comparative Analysis of Questionnaires for Dry Eye Screening Test (안구건조증 설문지의 일치도 연구)

  • Kim, Da-Young;Lee, Sun-Haeng;Cho, Hyun-Gug;Kim, Kun-Kyu;Kim, Ha-Na;Moon, Byeong-Yeon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.4
    • /
    • pp.499-504
    • /
    • 2014
  • Purpose: This study is to evaluate the accuracy of dry eye screening test by comparing coincidences between three types of questionnaires and objective tests. Methods: 90 adults were classified into the normal and dry eye groups using evaluations of three types of questionnaires (SPEED, OSDI, TERTC-DEQ) and objective tests (NIBUT, Schirmer test). Coincidences-between the results of objective tests and questionnaires were compared and analyzed for dry eye diagnosis. Results: Coincidences between NIBUT test and each questionnaire were 83.3% by SPEED, 77.8% by OSDI and 72.3% by TERTC-DEQ, respectively. Concordance by SPEED was highest among three types of questionnaire. Coincidences between the Schirmer test and each questionnaire were 57.8% by SPEED, 58.9% by OSDI and 73.3% by TERTC-DEQ, respectively, thus coincidence by TERTC was higher than by others. But coincidences by Schirmer test were generally lower than those by NIBUT test. Conclusions: SPEED questionnaire showed the highest concordance with objective test as compared with others. Therefore, SPEED is expected to be used usefully to diagnose dry eyes.

A study of Conjunctival Cellular Changes in Dry Eye Patients by Impression Cytology (Impression cytology를 이용한 건성안의 결막 세포변화에 관한 연구)

  • Kim, Jai-Min;Kho, Eun-Gyung;Chae, Soo-Chul;Kim, Soon-Ae
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.333-343
    • /
    • 2004
  • Impression cytology refers to application of cellulose acetate filter material to the ocular surface to remove the superficial layers of the conjunctival epithelium. The technique is non-invasive, is easy to perform, causes minimal discomfort to the patient, and can be used to follow changes in the conjunctival ocular surface over time. With this method, the morphology of the conjunctival ocular surface can be studied and the degree of squmaous metaplasia assessed. This study was performed to evaluate the conjunctival surface by impression cytology in dry eye patients. A total of 70 students with no contact lens wearing history were recruited. Subjects were required to fill in a McMonnies dry eye symptom questionnaire. The non-invasive tear thinning time(TIT) test of each subject was measured, followed by Schirmer tear test(STI), tear film break-up time(TBUT) tests and Rose-bengal staining were performed as a baseline. Conjunctival epithelial cells from the inferior bulbar conjunctiva were harvested by the impression cytology technique. The specimens collected were labelled and stained with PAS(Periodic Acid Schift)-haematoxylin. The goblet cells and conjunctival epithelial cells were observed under a light microscope of 400x magnification. The specimens were classified according to the Nelson Grading scale which was based on the degree of squamous metaplasia such as changes of goblet cells density, size/form, N:C(nucleus : cytoplasm) ratio. Dry eye patients were observed morphological changes of the epithelial cells, different nuclear alterations, decrease of the goblet cells density. The degree of cytological changes was related to severity of dry eye conditions. When the epithelial cell morphology was graded according to the system described by Nelson, specimens from the control group revealed 91.43% of the eyes to be grade 0 and 8.57% to be grade 1, whereas of the dry eye patients, 20% were grade 0, 42.86% grade 1, 34.29% grade 2 and 2,86% grade 3. Impression cytology represents a non- or minimally invasive biopsy of the ocular surface epithelium with no side effects or contraindications. It has demonstrated to be a useful diagnostic aid for a wide variety of processes involving the ocular surface. This technique is a safe, simple method and may help increase understanding of various ocular surface alterations in dry eye patients.

  • PDF

Comparison Among the Four Examination Methods for Dry Eye (OQAS test, TBUT, Schirmer Test, McMonnies test) (4가지 건성안 분석방법(OQAS test, TBUT, Schirmer test, McMonnies test)의 비교)

  • Park, Chang Won;Kim, Hyojin
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.519-526
    • /
    • 2015
  • Purpose: To evaluate the changes of OSI value according to tear-film instability measured serially by OQAS(Optical Quality Analysis System, Visiometrics, Spain) every seconds. The presented study analyzed the relationship of the OQAS parameter with the results of the tear-film break-up time, Schirmer test, and the McMonies score. Methods: 147 eyes of 82 subjects were randomly selected from university students (age: $21.51{\pm}3.97$, male 45, female 37). Subjects were measured tear-film break-up time, Schirmer test, McMonies score and once every second for 15 seconds after blinking by continuous measurements from OQAS system. Results: The normal eye groups presented OSI values of $2.13{\pm}1.16$ while the dry eye groups had OSI values of $3.76{\pm}1.42$. Therefore, a significant difference between the normal eye group and dry eye group was discovered (p<0.05). In addition, the OSI value of all subjects increased over time. The OSI value, which was measured every second after blinking occurred, significantly increased between 6 seconds and 7 seconds after the start of the measurement (p<0.05). OSI cut off of 30% (sec.) showed a greater correlation; TBUT (r = 0.855, p = 0.000), McMonies test (r = -0.351, p = 0.003), Schirmer (r = 0.316, p = 0.012). Conclusions: Continuous measurement of OQAS showed a high correlation with the value of the existing dry eye tests. Therefore, Analysis of OSI values by utilization of OQAS could be useful in objectively evaluation of tear film in patients.

Association of serum 25-hydroxyvitamin D concentrations with Schirmer tear test 1 and tear film breakup time in dogs

  • Youngsam Kim;Seonmi Kang;Kangmoon Seo
    • Journal of Veterinary Science
    • /
    • v.24 no.2
    • /
    • pp.32.1-32.10
    • /
    • 2023
  • Background: The association between vitamin D and canine keratoconjunctivitis sicca (KCS) has not been investigated in dogs. Objectives: To investigate the association of serum 25-hydroxyvitamin D [25(OH)D] concentrations with Schirmer tear test 1 (STT-1) and tear film breakup time (TFBUT) in dogs. Methods: Sixty-one clinically healthy, client-owned dogs were enrolled. STT-1 and TFBUT were measured in 122 (61dogs) and 82 (41 dogs out of total 61 dogs) eyes, respectively. Serum 25(OH)D concentrations were evaluated by quantitative chemiluminescent immunoassay. The dogs were classified into 6 groups according to the evaluations (STT-1: group 1, normal [≥ 15 mm/min] in both eyes; group 2, normal in one eye and abnormal [< 15 mm/min] in the fellow eye; group 3, abnormal in both eyes; TFBUT: group 4, normal [≥ 20 sec] in both eyes; group 5, normal in one eye and abnormal [< 20 sec] in the fellow eye; group 6, abnormal in both eyes). Results: STT-1 was positively correlated with TFBUT (p < 0.001). Among the STT-1 groups, the mean serum 25(OH)D concentration in group 1 was significantly higher than in groups 2 and 3 with positive correlation (p < 0.001). However, there were no significant differences among the TFBUT groups 4, 5, and 6. Conclusions: In dogs, it was found that serum 25(OH)D concentrations had a greater effect on quantitative KCS than qualitative KCS. Therefore, it is considered that measurement of serum 25(OH)D concentration could be included in the diagnostic tests in canine quantitative KCS patients.

Effects of Humidity Changes on Eyes (습도 변화가 눈에 미치는 영향)

  • Sun-Hee Han;Bong-Hwan Kim;So-Bin Kim;Min-Jung Kim;Hee-Kyung Park;Hyun-Ji Kim;Heon-Tae Kim;Hyeong-Su Kim
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1616-1624
    • /
    • 2023
  • Purpose. The purpose of this study was to investigate the effect of changes in tear break-up time, accommodative response amount, and accommodative microwave on the eyes due to changes in humidity. Methods. A total of 48 adult men and women in their 20s (21.1±1.56 years old) were surveyed on dry eye questionnaires (OSID questionnaires), tear destruction time was measured by humidity (40%, 60%, 80%), and controlled reactions and controlled fine waves were measured through tactile tests. Result. As a result of the OSID questionnaire, there were 10 normal patients, 8 mild dry eyes, 1 moderate dry eye, and 5 severe dry eyes. The initial tear film destruction time was 7.34±4.67 seconds at 40% humidity, 8.99±4.75 seconds at 60% humidity, 10.26±4.52 seconds at 80% humidity, and the average tear film destruction time was 9.51±4.07 seconds at 40% humidity, 10.99±3.82 seconds at 60% humidity, and 12.05±3.42 seconds at 80% humidity. The accommodative response was -0.41~1.79D at 40% humidity, -0.34~1.79D at 60% humidity, and -0.30~2.01D at 80% humidity. The accommodative microwave was measured as 56.39~63.43dB when it was 40%, 56.41~62.64dB when it was 60%, and 55.96 ~61.13dB when it was 80%. Conclusion. As the humidity (40~80%) increased, the tear break-up time increased, and as the accommodative stimulus amount increased, the accommodative response amount increased. It was found that the accommodative microwave according to the amount of accommodative stimulation increased, and as the humidity increased, the accommodative microwave decreased.

Development of Cellulose Strip for Dry Eye Inspection (건성안검사용 셀룰로즈 스트립 개발)

  • Lee, Myeonggu;Jeong, Myeong-jin
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.4
    • /
    • pp.355-359
    • /
    • 2019
  • Schirmer test is one of the most used methods for the diagnosis of dry eye. We attempted to develop a tear level measurement tool to replace unreliable Schirmer test with inaccurate results. Absorbency tests for various absorbents were carried out. As a result, ${\alpha}$ cellulose pulp was selected as the absorbent. Prototypes were produced and evaluated twice. Finally a tear level measurement tool in the form of a strip of ${\alpha}$ cellulose pulp adhered to a polyurethane was prepared. Usability evaluation of prepared tear level measurement tool was performed. As a result, it was confirmed that it has a significant correlation with SM tube developed oversea recently. In addition, it was judged to be useful as an alternative to the Schirmer test in terms of measurement time and accuracy.

A Study for Improvement of the Testing Methods for Quality Control of Recycled Aggregate (순환골재의 품질평가를 위한 시험방법 개선에 관한 실험적 연구)

  • Jaung, Jae-Dong;Lee, Do-Heun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.4
    • /
    • pp.105-114
    • /
    • 2008
  • This study investigates the saturation level of surface dryness, quantity of adhesive mortar, and the alien substance content of recycled aggregates for concrete to develop an adequate quality testing method for understanding the properties of recycled aggregates, which differ greatly from preexisting aggregates. For tests that measure the saturation level of surface dryness, where detail methods are applied differently according to the tester, various testing methods from across world were compared and analyzed. This study revealed that when measuring the saturation level of surface dryness of a certain sample, aggregates must be supplemented immediately whenever the height of the sample becomes lower than the measuring mold, and allowing the tamper to free fall on the sample will provide the most accurate results. When measuring the quantity of adhesive mortar of recycled aggregates for concrete, an acid solution was used, and since the quantity of adhesive mortar increases as the particle sizes gets smaller, the sample for testing should represent the entire granularity. Sulfuric acid solution is adequate for immersion, and the concentration should be 20% for best results. According to the alien substance content measurement, which was examined by the naked eye, the error range caused by the difference in particle size was neglectable, and therefore the sample should be $2.5{\sim}5.0mm$ in size concerning the accuracy and measuring time. Also, for coarse recycled aggregates, the sample should amount to 1kg for measuring alien substance content by the naked eye, which proves that assortment by the naked eye is the most adequate method for measuring the alien substance content of a recycled aggregate.