• Title/Summary/Keyword: drop system

Search Result 1,901, Processing Time 0.032 seconds

Experimental Evaluation of Bi-directionally Unbonded Prestressed Concrete Panel Impact-Resistance Behavior under Impact Loading (충돌하중을 받는 이방향 비부착 프리스트레스트 콘크리트 패널부재의 충돌저항성능에 대한 실험적 거동 평가)

  • Yi, Na-Hyun;Lee, Sang-Won;Lee, Seung-Jae;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.5
    • /
    • pp.485-496
    • /
    • 2013
  • In recent years, frequent terror or military attacks by explosion or impact accidents have occurred. Examplary case of these attacks were World Trade Center collapse and US Department of Defense Pentagon attack on Sept. 11 of 2001. These attacks of the civil infrastructure have induced numerous casualties and property damage, which raised public concerns and anxiety of potential terrorist attacks. However, a existing design procedure for civil infrastructures do not consider a protective design for extreme loading scenario. Also, the extreme loading researches of prestressed concrete (PSC) member, which widely used for nuclear containment vessel, gas tank, bridges, and tunnel, are insufficient due to experimental limitations of loading characteristics. To protect concrete structures against extreme loading such as explosion and impact with high strain rate, understanding of the effect, characteristic, and propagation mechanism of extreme loadings on structures is needed. Therefore, in this paper, to evaluate the impact resistance capacity and its protective performance of bi-directional unbonded prestressed concrete member, impact tests were carried out on $1400mm{\times}1000mm{\times}300mm$ for reinforced concrete (RC), prestressed concrete without rebar (PS), prestressed concrete with rebar (PSR, general PSC) specimens. According to test site conditions, impact tests were performed with 14 kN impactor with drop height of 10 m, 5 m, 4 m for preliminary tests and 3.5 m for main tests. Also, in this study, the procedure, layout, and measurement system of impact tests were established. The impact resistance capacity was measured using crack patterns, damage rates, measuring value such as displacement, acceleration, and residual structural strength. The results can be used as basic research references for related research areas, which include protective design and impact numerical simulation under impact loading.

A Study for Factors Influencing the Usage Increase and Decrease of Mobile Data Service: Based on The Two Factor Theory (모바일 데이터 서비스 사용량 증감에 영향을 미치는 요인들에 관한 연구: 이요인 이론(Two Factor Theory)을 바탕으로)

  • Lee, Sang-Hoon;Kim, Il-Kyung;Lee, Ho-Geun;Park, Hyun-Jee
    • Asia pacific journal of information systems
    • /
    • v.17 no.2
    • /
    • pp.97-122
    • /
    • 2007
  • Conventional networking and telecommunications infrastructure characterized by wires, fixed location, and inflexibility is giving way to mobile technologies. Numerous research reports point to the ultimate domination of wireless communication. With the increasing prevalence of advanced cell-phones, various mobile data services (hereafter MDS) are gaining popularity. Although cellular networks were originally introduced for voice communications, statistics indicate that data services are replacing the matured voice service as the growth engine for telecom service providers. For example, SK Telecom, the Korea's largest mobile service provider, reported that 25.6% of revenue and 28.5% of profit came from MDS in 2006 and the share is growing. Statistics also indicate that, in 2006, the average revenue per user (ARPU) for voice didn't change but MDS grew seven percents from the previous year, further highlighting its growth potential. MDS is defined "as an assortment of digital data services that can be accessed using a mobile device over a wide geographic area." A variety of MDS have been deployed, with a few reaching the status of killer applications. Many of them need to access the Internet through the cellular-phone infrastructure. In the past, when the cellular network didn't have acceptable bandwidth for data services, SMS (short messaging service) dominated MDS. Now, Internet-ready, next-generation cell-phones are driving rich digital data services into the fabric of everyday life, These include news on various topics, Internet search, mapping and location-based information, mobile banking and gaming, downloading (i.e., screen savers), multimedia streaming, and various communication services (i.e., email, short messaging, messenger, and chaffing). The huge economic stake MDS has on its stakeholders warrants focused research to understand associated dynamics behind its adoption. Lyytinen and Yoo(2002) pointed out the limitation of traditional adoption models in explaining the rapid diffusion of innovations such as P2P or mobile services. Also, despite the increasing popularity of MDS, unexpected drop in its usage is observed among some people. Intrigued by these observations, an exploratory study was conducted to examine decision factors of MDS usage. Data analysis revealed that the increase and decrease of MDS use was influenced by different forces. The findings of the exploratory study triggered our confirmatory research effort to validate the uni-directionality of studied factors in affecting MDS usage. This differs from extant studies of IS/IT adoption that are largely grounded on the assumption of bi-directionality of explanatory variables in determining the level of dependent variables (i.e., user satisfaction, service usage). The research goal is, therefore, to examine if increase and decrease in the usage of MDS are explained by two separate groups of variables pertaining to information quality and system quality. For this, we investigate following research questions: (1) Does the information quality of MDS increase service usage?; (2) Does the system quality of MDS decrease service usage?; and (3) Does user motivation for subscribing MDS moderate the effect information and system quality have on service usage? The research questions and subsequent analysis are grounded on the two factor theory pioneered by Hertzberg et al(1959). To answer the research questions, in the first, an exploratory study based on 378 survey responses was conducted to learn about important decision factors of MDS usage. It revealed discrepancy between the influencing forces of usage increase and those of usage decrease. Based on the findings from the exploratory study and the two-factor theory, we postulated information quality as the motivator and system quality as the de-motivator (or hygiene) of MDS. Then, a confirmative study was undertaken on their respective role in encouraging and discouraging the usage of mobile data service.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 - (공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰-)

  • Choi, Yong-Don;Kang, Yong-Tae;Kim, Nae-Hyun;Kim, Man-Hoe;Park, Kyoung-Kuhn;Park, Byung-Yoon;Park, Jin-Chul;Hong, Hi-Ki
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.1
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

Evaluation of Thermal Catalytic Decomposition of Chlorinated Hydrocarbons and Catalyst-Poison Effect by Sulfur Compound (염소계 탄화수소의 열촉매 분해와 황화합물에 의한 촉매독 영향 평가)

  • Jo, Wan-Kuen;Shin, Seung-Ho;Yang, Chang-Hee;Kim, Mo-Geun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.5
    • /
    • pp.577-583
    • /
    • 2007
  • To overcome certain disadvantages of past typical control techniques for toxic contaminants emitted from various industrial processes, the current study was conducted to establish a thermal catalytic system using mesh-type transition-metal platinum(Pt)/stainless steel(SS) catalyst and to evaluate catalytic thermal destruction of five chlorinated hydrocarbons[chlorobenzene(CHB), chloroform(CHF), perchloroethylene (PCE), 1,1,1-trichloroethane(TCEthane), trichloroethylene(TCE)]. In addition, this study evaluated the catalyst poison effect on the catalytic thermal destruction. Three operating parameters tested for the thermal catalyst system included the inlet concentrations, the incineration temperature, and the residence time in the catalyst system. The thermal decomposition efficiency decreased from the highest value of 100% to the lowest value of almost 0%(CHB) as the input concentration increased, depending upon the type of chlorinated compounds. The destruction efficiencies of the four target compounds, except for TCEthane, increased upto almost 100% as the reaction temperature increased, whereas the destruction efficiency for TCEthane did not significantly vary. For the target compounds except for TCEthane, the catalytic destruction efficiencies increased up to 30% to 97% as the residence time increased from 10 sec to 60 sec, but the increase of destruction efficiency for TCEthane stopped at the residence time of 30 sec, suggesting that long residence times are not always proper for thermal destruction of VOCs, when considering the destruction efficiency and operation costs of thermal catalytic system together. Conclusively, the current findings suggest that when applying the transition-metal catalyst for the better destruction of chlorinated hydrocarbons, VOC type should be considered, along with their inlet concentrations, and reaction temperature and residence time in catalytic system. Meanwhile, the addition of high methyl sulfide(1.8 ppm) caused a drop of 0 to 50% in the removal efficiencies of the target compounds, whereas the addition of low methyl sulfide (0.1 ppm), which is lower than the concentrations of sulfur compounds measured in typical industrial emissions, did not cause.

Experimental Study on Combined Failure Damage of Bi-directional Prestressed Concrete Panel under Impact-Fire Loading (충돌 후 화재에 대한 이방향 프리스트레스트 콘크리트 패널부재의 복합 파괴손상에 관한 실험적 연구)

  • Yi, Na-Hyun;Lee, Sang-Won;Choi, Seung-Jai;Kim, Jang-Ho Jay
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.429-440
    • /
    • 2014
  • Since the World Trade Center and Pentagon attacks in 2001, terror, military attack, or man-made disaster caused impact, explosion, and fire accident have frequently occured on civil infrastructures. However, structural behavior researches on major Prestressed Concrete (PSC) infrastructures such as bridges, tunnels, Prestressed Concrete Containment Vessel (PCCVs), and LNG tanks under extreme loading are significantly lacking. Especially, researches on possible secondary fire scenarios after terror, bombing, collision of vehicles and vessels on concrete structures have not been performed domestically where most of the past researches related to extreme loadings on structures focused on an independent isolated extreme loading scenario. Due to the outcry of public concerns and anxiety of potential terrorist attacks on major infrastructures and structures, a study is urgently needed at this time. Therefore, in this study, the bi-directional prestressed concrete $1400{\times}1000{\times}300mm$ panels applied with 430 kN prestressing force using unbonded prestressing thread bars were experimentally evaluated under impact, fire, and impact-fire combined loadings. Due to test site restrictions, impact tests were performed with 14 kN impactor with drop heights of 10m and 3.5 m to evaluate impact resistance capacity. Also, fire and impact-fire combined loading were tested using RABT fire loading curve. The measured residual strength capacities of PSC and RC specimens applied with impact, fire, impact-fire combined loadings were compared with the residual strength capacity of undamaged PSC and RC specimens for evaluation. The study results can be used as basic research data for related research areas such as protective design and numerical simulation under extreme loading scenarios.

Evaluation for Soil Moisture Stabilization and Plant Growth Response in Horizontal Biofiltration System Depending on Wind Speed and Initial Soil Moisture (풍속과 초기 토양수분에 따른 평면형 바이오필터 내 토양수분 안정화 및 식물 생육반응 평가)

  • Choi, Bom;Chun, Man Young;Lee, Chang Hee
    • Korean Journal of Plant Resources
    • /
    • v.27 no.5
    • /
    • pp.546-555
    • /
    • 2014
  • The final aim of this study is to develop a biofiltration system integrated with plant vegetation for improving indoor air quality effectively depending on indoor space and characteristics. However, to approach this final goal, several requirements such as constant pressure drops (PDs) and soil moisture contents (SMCs), which influence the capacity design for a proper ventilation rate of biofiltration system, should be satisfied. Thus, this fundamental experiment was carried out to adjust a proper wind speed and to ensure a stabilization of initial SMCs within biofilter for uniform distribution of SMCs and PDs, and for normal plant growth, especially avoiding root stress by wind. Therefore, we designed horizontal biofliter models and manufactured them, and then calculated the ventilation rate, air residence time, and air-liquid ration based on the biofilter depending on three levels of wind speed (1, 2, and $3cm{\cdot}s^{-1}$). The relative humidity (RH) and PD of the humidified air coming out through the soil within the biofilter, and SMC of the soil and plant growth parameters of lettuce and duffy fern grown within biofilter were measured depending on the three levels of wind speed. As a result of wind speed test, $3{\cdot}sec^{-1}$ was suitable to keep up a proper RH, SMC, and plant growth. Thus, the next experiment was set up to be two levels of initial SMCs (low and high initial SMC, 18.5 and 28.7%) within each biofilter operated and a non-biofiltered control (initial SMC, 29.7%) on the same wind speed ($3cm{\cdot}sec^{-1}$), and measured on the RH and PD of the air coming out through the soil within the biofilter, and SMC of the soil and plant growth parameters of Humata tyermani grown within biofilter. This result was similar to the first results on RHs, SMCs, and PDs keeping up with constant levels, and three SMCs did not show any significant difference on plant growth parameters. However, two biofiltered SMCs enhanced dry weights of the plants slightly than non-biofiltered SMC. Thus, the stability of this biofiler system keeping up major physical factors (SMC and PD) deserved to be adopted for designing an advanced integrated biofilter model in the near future.

Performance Comparison between Indirect Evaporative Coolers made of Aluminum, Plastic or Plastic/Paper (알루미늄, 플라스틱, 플라스틱/종이 재질의 간접 증발 소자 성능 비교)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8165-8175
    • /
    • 2015
  • In Korea, summer is hot and humid, and air-conditioners consume lots of electricity. In such case, simultaneous usage of indirect evaporative cooler may reduce the sensible heat and save the electricity. In this study, heat transfer and pressure drop characteristics of indirect evaporative cooler made of aluminum, plastic, plastic/paper are investigated both under dry or wet condition. Results show that indirect evaporation efficiencies of the plastic/paper sample (38.5% ~ 51.4%) are approximately the same as those of the aluminum sample (41.9% ~ 47.5%), and are larger than those of the plastic sample (29.0% ~ 37.4%). This suggests that the plastic/paper sample could be a good substitute to the aluminum sample. However, the pressure drops across the paper channel are 92% ~ 106% larger than those across the aluminum channel. The heat transfer coefficients of the paper channel under dry condition are 15% ~ 44% larger than those of the plastic channel. The increases are 185% ~ 203% for the aluminum channel. The pressure drops of the paper channel are 34% ~ 48% larger than those of the plastic channel and 93% ~ 106% larger than those of the aluminum channel. Rigorous heat transfer analysis reveals that, for the plastic sample, 30% ~ 37% of the wet channels remain dry, whereas all the channels are wet for plastic/paper sample. For aluminum sample, the ratio is 17% ~ 23%.

A Comparative Study on Chinese Adult women's constitutional components and Somatotype Characteristic (지역별.연령별 중국 성인여성(地域別.年齡別 中國 成人女性)의 체형구성 요인(體型構成 要因)과 유형 비교 연구(類型 比較 硏究))

  • Wee, Hye-Jung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.10 no.5
    • /
    • pp.58-73
    • /
    • 2006
  • The purpose of this study was to improve of fittness and coverage rate of exporting domestic clothing to China for Chinese Adult Female. For study, It was measured 1381 female women aged between 19 and 50 who resident in Beijing and Shanghai in China. as a sample, 1360 female women was seleted for development of apparel sizing system. As for the method of this study was made of 111 items by indirect measures done during Jun. 23 $\sim$ Aug. 7, 2004. Data analysis were processed by SPSS WIN 10.0 Program was used to for technical statistical analysis, correlation analysis, factor analysis, ANOVA(t-test and F-test), duncan's multiple test. The result was as follows: Chinese Adult women's constitutional components determined by factor analysis, six components could be identified: factor 1:constitutional obesty and width size, factor 2: longistudinal body size, factor 3: shoulder form and size, factor 4: longistudinal upper body size, factor 5: under body size, factor 6: shoulder dropping. According to the Women's Wear Specifications(GB/T 1335.2-1997) by drop, body types of Chinese Adult female was classified into six types, it was Y, A, B, C and Z, D. In order, A type as standard somatotype(49.8%), B type(26.9%), Y type (18.8%), C type(2.9%). Y type had the average height and shoulder, bust girth. They were slimmer in overall terms. A type had a normal obesity and body size in height, shoulder, bust girth. They were average Chinese Women. B type had a smaller then A type. They were more obes and thick waist girth. C type had the highest obesity, the widest shoulder and bust girth, and thick waist girth. The characteristics of each body type following the body type structure factor are Y-type for slender type, A-type for standard type, B-type for slightly large type, and C-type for obese type. For each region, the Beijing area had in the order of A-type, Y-type, B-type and C-type, and the Shanghai area had in the order of A-type, B-type, Y-type and C-type.

Effects of Inert Gas Composition Variations in Biogas on the Performance of a SI Engine (바이오가스 내의 불활성 가스 성분 변화가 SI 엔진 성능에 주는 영향)

  • Lee, Sunyoup;Park, Seunghyun;Park, Cheolwoong;Kim, Changgi;Lee, Janghee;Woo, Sejong
    • Journal of the Korean Institute of Gas
    • /
    • v.16 no.5
    • /
    • pp.14-20
    • /
    • 2012
  • Biogas can be obtained from biogenic materials through an anaerobic digestion process. Since biogas has low calorific value and its composition significantly varies, appropriate combustion strategies need to be established to obtain stable combustion in engine applications. In this study, efforts have been made to investigate the effects of inert gas composition variations on engine performance and emissions. Results show that the MBT spark timing was advanced and $NO_x$ was reduced as the inert gas in the biogas rose. Moreover, $NO_x$ emission drop in $CO_2$ diluted biogas was more significant than that of $N_2$ due to higher heat capacity of $CO_2$, while THC emissions showed the opposite tendency. Thermal efficiency was increased in $N_2$ case with elevation of $N_2$ due to the decreased heat loss and PMEP. However, there is no difference in $CO_2$ case because of deteriorated flame propagation speed.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.