One of the most effective methods to consistently ensure the safety of a tap water supply can be achieved by application of a comprehensive risk assessment and risk management approach for drinking water supply systems. This approach can be termed water safety plans(WSP) which recommended by WHO(world health organization) and IWA(international water association). For the introduction of WSP into Korea, 150 hazards were identified all steps in drinking water supply from catchment to consumer and risk assessment tool based on frequency and consequence of hazards were developed. Then, developed risk assessment tool by this research was implemented at a water treatment plant($Q=25,000m^3/d$) to verify its applicability, and several amendments were recommended; classification of water source should be changed from groundwater to stream to strengthen water quality monitoring contaminants and frequencies; installation of aquarium to monitor intrusion of toxic substances into raw water; relocation or new installation on-line water quality analyzers for efficient water quality monitoring; change of chlorination chemical from solid phase($Ca(OCl)_2$) to liquid phase(NaOCl) to improve soundness of chlorination. It was also meaningful to propose hazards and risk assessment tool appropriate for Korea drinking water supply systems through this research which has been inconsistent among water treatment authorities.
Proceedings of the Korean Society of Soil and Groundwater Environment Conference
/
2003.04a
/
pp.225-228
/
2003
For the purpose of finding out the distributions of groundwater uses, the effect of facilities on the parameter and the correlations among measurements, various statistical analysis were carried out with the data of groundwater quality measurements from January to December in 2002. 1. The rates of groundwater for drinking water were 10.5% in Yangcheon-Gu, 10.2% in Kangdong-Gu, and 9.9% in Eunpyung-Gu. The rates of other uses of groundwater were shown to be 58.1%(786 wells) for civil defense emergency, 22.1%(299 wells) for contamination-concerning, 9.8%(133 wells) for water quality monitoring, consisting of 90% of all groundwater. 2. The 52.6% of groundwater for drinking were demonstrated to be appropriate while 91.9% for tither uses-domestic, industrial, agricultural uses- were shown to be proper. 3. For drinking water, the average values of colar, turbidity, NH3-N, F, and Fe were 11.216 degree, 2.138 NTU, 2.458mg/l, 0.212mg/1 and 0.507mg/1 respectively. 4. In cases of drinking water wells for emergency, the results of statistical analysis showed that building year of the wells, depth and pumping rate didn't affect on whether it was proper for that use or not. It were shown that there were linear correlations between depth and NO$_3$-N(-0.171) and F ̄(0.332) while the correlation coefficients were 0.381 and -0.169 between the building year of well and depth and pumping rate respectively.
The characteristics of drinking groundwater quality was analyzed by investigating observed data during 1995-1997 in Daejeon city. As the analysis of observed data, the 30.1% of them were over the drinking water quality standards in Daejeon city and the unfit ratios of each region were 36.4% at Dong-Gu, 32.3% Daedeog-Gu, 31.2% Jung-Gu, 30.0% Seo-Gu and 25.2% at Yusoung-Gu. It was found that the items over the drinking water quality standards were 24 items and all of the mean concentration of water quality items were under the drinking water quality standard except Fe and Mn in 1997. The mean concentration of Fe was $1.31mg/{\ell}$ over the water quality at Daedeog-Gu and that of Mn was $0.53mg/{\ell}$ at Jung-Gu. The concentrations of $NH_3$-N, Mn, Fe, Al and F were increased rapidly in 1997, so that the cause of increasing also must be examined closely. It was found that the rainfall and unfit ratio(unfit frequency/test frequency) of E-coli and bacteria had the hydrologic persistance. The coefficient of correlation between them was 0.525. On the rainfall over 100mm, it was 0.673 and on the rainfall over 150mm, it was 0.641. The correlation between E-coli and rainfall was higher than that between bacteria and rainfall.
Kim, Jong-Min;Kim, Ha-Ram;Jang, Seo-Eun;Choi, Yeong-Seop;Kang, Yu-Mi;Jung, Sook-Kyoung;Cho, Young-Gwan;Kim, Eun-Sun
Journal of Environmental Health Sciences
/
v.43
no.2
/
pp.143-156
/
2017
The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.
The water quality of Paldang reservoir now grades the third class water based on COD criterion, meaning that it is no longer suitable for drinking. This study attempted to estimate the economic value of water quality improvement in Paldang reservoir using CVM. The survey used payment card format to measure the willingness to pay of the questionnaire respondents for the improvement of water quality and also factors that affect the WTP. The survey showed that men rather than women, those had higher income and paid more water supply charges, those who lived in the area for a shorter period of time, those who do not use city water for drinking, had willingness to pay more. The WTP was estimated 4,952 to 5,497 won on a monthly average. The economic value of the improvement of the water quality of Paldang reservoir was estimated between 344.2~382.1 billion won on an annual basis.
Kim, Sang-Goo;Park, Hong-Gi;Son, Hee-Jong;Yoom, Hoon-Sik;Ryu, Dong-Choon
Journal of Environmental Science International
/
v.24
no.12
/
pp.1551-1558
/
2015
In Korea, many drinking water treatment plants (DWTPs) have introduced and are going to introduce biological activated carbon (BAC) process to treated dissolved organic matter (DOM) in water which are difficult to control by conventional water treatment processes. Even though more decade have passed since introduced BAC in Korea, most of BAC operating method was followed to the modified sand filter operating manuals. In case of BAC backwashing, many DWTPs set the periods of backwashing about 3~5 days. In this study, we have collected data to set the proper BAC backwashing periods from both pilot-plant and real DWTPs. We had measured heterotrophic plate count (HPC), turbidity, water temperature, dissolved organic carbon (DOC) and headloss from just after backwashing to the next backwashing time for two years. Considering water quality factors, the BAC run time from backwashing to the next backwashing could extend more 30 days without water quality deterioration if the head loss do not reach the limited level which depends on each BAC facilities' condition. It means the BAC treated water could be saved in the proportion of extended the backwashing period to the existing backwashing period.
Evaluation of groundwater quality is vital due to its diverse use for several purposes. In the present study, groundwater quality and suitability from the Peshawar basin, Pakistan, were evaluated for drinking and irrigation purposes. The water samples were analysed for major cations (Ca, Mg, Na and K) and anions (chloride, bicarbonate and sulphate) along with other physicochemical parameters (pH, electrical conductivity, total dissolved solids, and total hardness). About 95% of the water samples were found to be within the WHO, US-EPA and Pak-EPA permissible levels for drinking purposes. Seventy percent (70%) of the water samples belonged to the hard water category. Irrigation water quality parameters, such as, chloride, residual sodium bicarbonate, sodium adsorption ratio, percent sodium, magnesium adsorption ratio, Kelly's ration and permeability index were evaluated which demonstrated that the groundwater was highly to moderately suitable for irrigation. A correlation study was conducted to find out the mutual associations among the variables. Piper diagram indicated the overall chemical nature of the study area was calcium-magnesium bicarbonate type. Cluster analysis revealed mutual apportionment of various parameters in the groundwater of the Peshawar basin, Pakistan.
There are many possibilities that may lead to low quality of drinking water Recently, some unknown deposits in tap water raised a lot of public concern regarding the safety of drinking water in Seoul. We analyzed the quality of tap water from several areas of Seoul, including the area where public complaints about tap water were high. The results shows that the quality of tap water in Seoul was good, well below the environmental standards. Only the tap water from the area with high public complaints showed turbidity higher than that of other area. Also, result shows that component of deposit in tap water was Al, Fe, Mn, and Zn. Based on the research result we propose several measures that might help to reduce the amount of deposit in tap water as follows : 1 Using coagulant aid when coagulating or adjusting pH when filtering. 2. Replacing old water pipeline with new corrosive- resistant one. 3. Increasing water treatment efficiency by enhancing water treatment system such as automation of water treatment system adjusting production capacity, and improving operational condition of filler basin. 4. Chlorine disinfection at the distribution reservoir would help maintaining the same pH level and chlorine concentration throughout the water pipeline and reduce corrosion of pipe.
In this study, chlorine dose at water storage tank was predicted to meet the recommended guideline for free chlorine residual in drinking water distribution system, using EPANET which is a computer program that performs extended Period simulation of hydraulic and water quality behavior within pressurized pipe networks. The results may be summarized as follows. The decay of chlorine residual by season varied considerably in the following order; in summer ($25^{\circ}C$) > spring and fall (15$^{\circ}C$) > winter (5$^{\circ}C$). For re-chlorination at water storage tank by season, season-varying chlorine dose was required at its maximum of 1.00 mg/l in summer and minimum of 0.40 mg/l in winter as free chlorine residual. The decay of chlorine residual through out the networks increased with water age spent by a parcel of water in the network except for some points with low water demand. In conclusion, the season-varying chlorine dose as well as the monitoring of water quality parameters at the some points which showed high decay of chlorine residual may be necessary to deliver the safe drinking water.
The purpose of this study is to raise the drinking rate of Arisu, the tap water in Seoul, and to propose new solution for continuous water quality management and raising awareness. The research scope was limited to point-of-use water treatment system, and based on the this contents I proceed this study how this will help to increase direct drinking rate of Arisu. Through research, Korea has provided users with the ability to filter contaminated tap water simply as water to be rinsed through water purification. Therefore, it was predicted that it would be difficult to improve tap water as drinking water. With this study, I expect that the strength of point-of-use system and the reliability of tap water quality will be raised and hope various product will be developed to improve the perception as drinking water and I also expect that this can be applied to whole country even further in the scope of Seoul city.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.