Evaluation of Water Quality Characteristics of Floor Fountains in Gwangju

광주지역 바닥분수의 수질특성 평가

  • Kim, Jong-Min (Health and Environment Research Institute of Gwangju) ;
  • Kim, Ha-Ram (Health and Environment Research Institute of Gwangju) ;
  • Jang, Seo-Eun (Health and Environment Research Institute of Gwangju) ;
  • Choi, Yeong-Seop (Health and Environment Research Institute of Gwangju) ;
  • Kang, Yu-Mi (Health and Environment Research Institute of Gwangju) ;
  • Jung, Sook-Kyoung (Health and Environment Research Institute of Gwangju) ;
  • Cho, Young-Gwan (Health and Environment Research Institute of Gwangju) ;
  • Kim, Eun-Sun (Health and Environment Research Institute of Gwangju)
  • 김종민 (광주광역시보건환경연구원) ;
  • 김하람 (광주광역시보건환경연구원) ;
  • 장서은 (광주광역시보건환경연구원) ;
  • 최영섭 (광주광역시보건환경연구원) ;
  • 강유미 (광주광역시보건환경연구원) ;
  • 정숙경 (광주광역시보건환경연구원) ;
  • 조영관 (광주광역시보건환경연구원) ;
  • 김은선 (광주광역시보건환경연구원)
  • Received : 2017.02.27
  • Accepted : 2017.03.08
  • Published : 2017.04.28

Abstract

The purpose of this study was to investigate water quality through a field survey at six floor fountain sites. The floor fountain facilities were designed and operated in such a way that tap water was stored in a water tank and recycled repeatedly. The water tank was cleaned once or twice per week in the summer. The number of facility users was low during the day due to sweltering heat, but up to 40 people, mainly children, were using them around 8 pm. Since the operation time was as short as 30 minutes, it is considered necessary to extend it for at least one hour for the number of users. As a result of the water quality test of the reservoir tank prior to operation after cleaning, it was measured to be within drinking water quality standards at the six facilities. As a result of the water quality test after use, ammonia nitrogen was measured to be 1.45 mg/L at Site IV. This exceeded the drinking water quality standard of 0.5 mg/L. In the case of turbidity, two cases exceed at 7.38 and 4.52 NTU when applying 4 NTU as the water quality standard for waterscape facilities. Twenty-eight cases exceed the standard of drinking water quality. The result of microbiological tests, at five sites excepting Site I, where disinfectant was injected, was that the maximum total colony count was 180,000 CFU/mL, total coliforms was 2,100,000 CFU/100 mL, fecal coliforms was 4,600 CFU/100 mL, Escherichia coli was 170 MPN/100 mL and Enterococcus was 100 CFU/100 mL. This exceeded the water quality standards of drinking water. Children are very likely to inhale because the water spews from below and falls from above, so it is necessary to apply water quality standards for ammonia nitrogen, turbidity and microbes. Current floor fountain facilities are highly susceptible to disease caused by microbial contamination because of water cycling and reuse, so it is necessary to change the water every day, clean the water tank, and perform chlorination. Therefore, it is necessary to inject calcium hypochlorite according to the free chlorine water quality standard of swimming pools with a different water tank capacity. In addition, facilities should be improved to prevent the reuse of water by installing the water tank at a separate location.

Keywords

References

  1. 환경부, "물놀이형 수경시설의 수질관리지침" (2010. 8.)
  2. 윤상훈, 김선경, 김난희, 위환, 이세행, 조광운, 김동수, 조영관, "물놀이형 수경시설의 수질과 항생제 내성 대장균 분포에 관한 연구", 한국환경보건학회지 2014; 40(3): 225-233. https://doi.org/10.5668/JEHS.2014.40.3.225
  3. 환경부, "수경시설 수질관리방안 연구", 최종보고서 (2010. 7.).
  4. 환경부 보도자료, "아이들 노는 바닥분수 수질검사 의무화 등 제도개선", (2016. 1.).
  5. 환경부, 환경부고시 제2015-214호, 먹는물수질공정 시험기준 (2015. 11.).
  6. 환경부, 환경부고시 제2014-163호, 수질오염공정시험기준 (2014. 9.).
  7. Method 1600: Enterococci in Water by Membrane Filtration Using membrane-Enterococcus Indoxyl-B-D-Glucoside Agar (mEI), July 2006.
  8. 김정아, 이세화, 기민석, 김종임, 허영선, "물놀이분수의 수질실태 조사에 관한 연구" 대전광역시보건 환경연구원 (2012).
  9. 유은희, 유숙진, 정태욱, 지화성, 박은희, 이경심, "부산시내 물놀이형 수경시설 수질특성 및 관리항목 개선에 관한 연구", 부산광역시보건환경연구원 (2014).
  10. Swimming Pool and Water Recreation Facilities Ordinance (USA, 2012).
  11. Bathing Water Directive, 76/160/EEC
  12. Centers for Disease Control and Prevention (CDC). 1998. Outbreak of cryptosporidiosis associated with a water sprinkler fountain-Minnesota, 1997. MMWR Morb Mortal Wkly Rep. 16; 47(40): 856-62.
  13. Sell, A.F., 1994. Phytoplanton-excreted organic carbon. in Overbeck, J. and R.J. Chrost (eds) Microbial Ecology of Lake Plusssee. Springer-Verlag New York. pp 81-91.
  14. 송주훈, 채수천, 강보익, 유두철, 정상돈, 이미선, 박소영, 정주리, 박미연, "물놀이 분수시설 수질 실태 조사", 전라북도보건환경연구원보 (2010).
  15. 김경민, "물놀이형 수경시설 수질관리를 위한 개선 방안", 국회입법조사처 (2014).
  16. 송영상, 이재호, 류권걸, 김명희, 심재순, "도내 공공수영장의 효율적인 관리방안 연구", 충청북도보건 환경연구원 (2014).