• Title/Summary/Keyword: drain

Search Result 2,238, Processing Time 0.028 seconds

Focus Group Interview on Opinion about the Design and Management of Toothbrushing Facilities (양치시설 설계 및 운영에 대한 관련 실무자의 견해: 초점집단면접 연구)

  • Lee, Hyo-Jin;Paik, Dai-Il
    • Journal of dental hygiene science
    • /
    • v.16 no.2
    • /
    • pp.118-126
    • /
    • 2016
  • This study collected opinions about the design and management of toothbrushing facilities from schoolteachers and the people in charge of public centers, through a focus group interview (FGI), for the development of guidelines. Four moderators conducted eight FGIs of 32 subjects in charge of toothbrushing facilities across all the regions. The qualitative data was analyzed by constant comparative analysis. The findings indicated that more students utilized the facility and brushed their teeth after the installation of toothbrushing facilities. To enhance students' accessibility and safety, guidelines for design and management guidelinesfor toothbrushing facilities need to be developed; the location, sink height and depth, drain size, etc. should be comprehensively considered in the development of the guidelines. This study can help to improve students' satisfaction by enhancing the accessibility, safety, and functionality of toothbrushing facilities, and by providing fundamental data for toothbrushing facilities' development. Finally, this study can maximize the effects of management of toothbrushing facilities management on the improvement of students' oral health and behaviors.

The Improvement of Fabrication Process for a-Si:H TFT's Yield (a-Si:H TFT의 수율 향상을 위한 공정 개선)

  • Hur, Chang-Wu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.6
    • /
    • pp.1099-1103
    • /
    • 2007
  • TFT's have been intensively researched for possible electronic and display applications. Through tremendous engineering and scientific efforts, a-Si:H TFT fabrication process was greatly improved. In this paper, the reason on defects occurring at a-Si:H TFT fabrication process is analyzed and solved, so a-Si:H TFT's yield is increased and reliability is improved. The a-Si:H TFT of this paper is inverted staggered type TFT. The gate electrode is formed by patterning with length of $8{\mu}m{\sim}16{\mu}m$ and width of $80{\sim}200{\mu}m$ after depositing with gate electrode (Cr). We have fabricated a-SiN:H, conductor, etch-stopper and photo-resistor on gate electrode in sequence, respectively. We have deposited n+a-Si:H, NPR(Negative Photo Resister) layer after forming pattern of Cr gate electrode by etch-slower pattern. The NPR layer by inverting pattern of upper Sate electrode is patterned and the n+a-Si:H layer is etched by the NPR pattern. The NPR layer is removed. After Cr layer is deposited and patterned, the source-drain electrode is formed. The a-Si:H TFT made like this has problems at photo-lithography process caused by remains of PR. When sample is cleaned, this remains of PR makes thin chemical film on surface and damages device. Therefor, in order to improve this problem we added ashing process and cleaning process was enforced strictly. We can estimate that this method stabilizes fabrication process and makes to increase a-Si:H TFT's yield.

Effect of Thermophilic Ammonium Tolerant Bacteria on Malodors Emission of Composting of Pig Manure (돈분 퇴비화 과정중 악취물질에 대한 고온성 암모니움 내성균 접종 효과)

  • Seo, Myung-Chul;Kuroda, Kazutaka;Hanajima, Dai;Haga, Kiyonori
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.31 no.1
    • /
    • pp.77-84
    • /
    • 1998
  • In order to investigate microbiological control of malodors, particularly including ammonia, the effect of three thermophilic ammonium tolerant bacteria strains. TAT112. TAT117 and TAT119, were tested during composting of pig manure in the laboratory scale composters. The total weight, volatile solids and BOD of the pig manure compost were decreased during composting process in all treatments. The temperature in all treatments rose in first 3 days dramatically, but that in control without inoculation reached its maximum most lately among the treatments. The nitrogen content of drain water accumulated inside and outside composter, and trapped in 6N $H_2SO_4$ was lower in TAT112 inoculated composter than in control. However, it was not lower in the treatment of TAT117 and TAT119 inoculated. Ammonia concentration in the exhaust gas monitored everyday during composting also demonstrated that it was lowest at TAT112 inoculated among all treatments. It was appeared to have an effect on reducing ammonia emission at the treatment of TAT112 inoculated than the control.

  • PDF

DC and RF Characteristics of 100-nm mHEMT Devices Fabricated with a Two-Step Gate Recess (2단계 게이트 리세스 방법으로 제작한 100 nm mHEMT 소자의 DC 및 RF 특성)

  • Yoon, Hyung Sup;Min, Byoung-Gue;Chang, Sung-Jae;Jung, Hyun-Wook;Lee, Jong Min;Kim, Seong-Il;Chang, Woo-Jin;Kang, Dong Min;Lim, Jong Won;Kim, Wansik;Jung, Jooyong;Kim, Jongpil;Seo, Mihui;Kim, Sosu
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.282-285
    • /
    • 2019
  • A 100-nm gate-length metamorphic high electron mobility transistor(mHEMT) with a T-shaped gate was fabricated using a two-step gate recess and characterized for DC and microwave performance. The mHEMT device exhibited DC output characteristics having drain current($I_{dss}$), an extrinsic transconductance($g_m$) of 1,090 mS/mm and a threshold voltage($V_{th}$) of -0.65 V. The $f_T$ and $f_{max}$ obtained for the 100-nm mHEMT device were 190 and 260 GHz, respectively. The developed mHEMT will be applied in fabricating W-band monolithic microwave integrated circuits(MMICs).

Evaluation of Surgical Completeness in Endoscopic Total Thyroidectomy with Central Neck Dissection via a Unilateral Axillo-Breast Approach Compared with Bilateral Axillo-Breast and Open Approach (양측 액와유방 접근법과 개방성 접근법과의 비교를 통한 일측 액와유방 접근 내시경 갑상선 전 절제술과 중심 경부 절제술의 수술적 완전성에 대한 평가)

  • Choi, Ik Joon;Lim, Ilhan;Lee, Byeong-Cheol;Lee, Guk Haeng;Lee, Myung-Chul
    • Korean Journal of Otorhinolaryngology-Head and Neck Surgery
    • /
    • v.61 no.12
    • /
    • pp.697-701
    • /
    • 2018
  • Background and Objectives The aim of this study was to evaluate surgical completeness in endoscopic total thyroidectomy with central neck dissection via unilateral axillo-breast approach (UABA) compared with bilateral axillo-breast (BABA) and open approach (OA) by means of the radioactive iodine uptake (RAIU) ratio and thyroglobulin (Tg) of remnant thyroid. Subjects and Method From July 2010 to March 2013, 82 patients who had underwent total thyroidectomy with central neck dissection and postoperative radioactive iodine (RAI) ablation for papillary thyroid carcinoma were enrolled. Of these patients, 27 patients underwent UABA, 24 patients BABA, and 31 patients OA. Clinicopathologic data, surgical outcome, stimulated Tg and RAIU ratio on the first postoperative RAI ablation scan were compared among 3 groups. Results Patients in the endoscopic surgery groups (UABA, BABA) were younger than those in the OA groups. Invasiveness such as operation time, postoperative pain, and drain amount in UABA was less than that in BABA and severer than that in OA. Other variables regarding clinicopathologic and surgical data were not significantly different. Stimulated Tg and RAIU ratio did not show significant differences among 3 groups (p=0.659 and p=0.664). Conclusion The completeness of UABA was comparable with that of BABA and OA. The UABA may be a safe option for patients who need endoscopic thyroidectomy for papillary thyroid carcinoma.

Experimental study of the air emission effect in the tangential and the multi-stage spiral inlet (접선식 유입구와 다단식 나선 유입구의 공기 배출 효과에 관한 실험적 연구)

  • Seong, Hoje;Rhee, Dong Sop;Park, Inhwan
    • Journal of Korea Water Resources Association
    • /
    • v.52 no.4
    • /
    • pp.235-243
    • /
    • 2019
  • Recently, urban inundation was frequently occurred due to the intensive rainfall exceeding marginal capacity of the flood control facility. Furthermore, needs for the underground storage facilities to mitigate urban flood are increasing according to rapidly accelerating urbanization. Thus, in this study, drainage efficiency in drain tunnel connecting to underground storage was investigated from the air-core measurements in the drop shaft against two types of inlet structure. In case of the spiral inlet, the multi-stage structure is introduced at the bottom of the inlet to improve the vortex induction effect at low inflow discharge (multi-stage spiral inlet). The average cross-sectional area of the air-core in the multi-stage spiral inlet is 10% larger than the tangential inlet, and show the highly air emission effect and the highly inflow efficiency at the high inflow discharge. In case of the tangential inlets, the air emission effect decreased after exceeding the maximum inflow discharge, which is required to maintain the inherent performance of the tangential inlet. From the measurements, the empirical formula for the cross-sectional area of the air-core according to locations inside the drop shaft was proposed in order to provide the experimental data available for the inlet model used in experiments.

An Analysis of the Effect of PBD Discharge Capacity to Leave Period (방치기간에 따른 PBD의 통수능 효과 분석)

  • Lee, Keeyong;Park, Minchul;Jeong, Sangguk;Lee, Song
    • Journal of the Korean GEO-environmental Society
    • /
    • v.12 no.10
    • /
    • pp.39-49
    • /
    • 2011
  • Recently PBD method, one of acceleration of consolidation methods is used in the soft ground to shorten consolidation time for fast settlement during construction. It is economical and easy to work. Discharge capacity of PBD is sensitive in proportion to thickness of soft ground layer, and drainage of PBD declines due to disturbance effect in surrounding ground by mandrel used for vertical drainage setting and setting machines and type. Also, deviation of discharge capacity is large according to ground condition, construction condition and soil properties. In addition, when embankment loading is not conducted instantly after PBD setting due to rain or lack of embankment material supply, it causes leaving period problems. But cause and analysis of those problems for discharge capacity is lack. So, in this test, ground improvement and discharge capacity is investigated by implementing composite discharge capacity test for analysis of an effect factor of PBD discharge capacity with leaving period. After fixing the vertical drain on a cylindrical cylinder, put churned sample into the cylinder. Then leave 0day, 30day, 60day and 90day. And then, load following the loading step of 30, 70 and 120kPa using a pressure device. As a result, the longer leaving period, discharge capacity is reduced. It is caused by a decrease of discharge area caused by creep transformation moisture absorption of PBD filter after long leaving period.

Performance of Pentacene-based Thin-film Transistors Fabricated at Different Deposition Rates (증착 속도에 따른 펜타센 박막 트랜지스터의 성능 연구)

  • Hwang, Jinho;Kim, Duri;Kim, Meenwoo;Lee, Hanju;Babajanyan, Arsen;Odabashyan, Levon;Baghdasaryan, Zhirayr;Lee, Kiejin;Cha, Deokjoon
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1192-1195
    • /
    • 2018
  • We studied the electrical properties of organic thin-film transistors (OTFTs) fabricated at different deposition rates by measuring the field-effect mobility and the threshold voltages. As the active layer, pentacene thin film with a thickness of 50 nm was deposited at a rate of $0.05{\AA}/s$ to $1.14{\AA}/s$. The thickness of the drain-source gold electrode was 50 nm. The mobility was $1.9{\times}10^{-1}cm^2/V{\cdot}s$ at a deposition rate of $0.05{\AA}/s$, the mobility increased to $5.2{\times}10^{-1}cm^2/V{\cdot}s$ when the deposition rate was increased to $0.4{\AA}/s$, and then the mobility decreased to $6.5{\times}10^{-1}cm^2/V{\cdot}s$ when the deposition rate decreased to $1.14{\AA}/s$. Thus, the mobility of pentacene OTFTs was observed to depend on the thermal deposition rate.

Transition from Linear Economy to Circular Economy (선형경제에서 순환경제로의 전환)

  • Kim, Joon Soo;Jun, Yun-Su;Jun, Jung Hyuk;Cho, Jai Young
    • Resources Recycling
    • /
    • v.30 no.3
    • /
    • pp.3-17
    • /
    • 2021
  • Currently, there is a drain of natural resources, environmental contamination, generation of waste, and problems of the earth's climate by CO2 emissions according to mass production and overconsumption of mankind. It is effectuated by a linear economy that involves manufacturing products, use, and waste repeatedly; there is no guarantee in the lives of humans and the future of the globe if we do not find alternative proposals. For a sustainable developing society and to overcome the present global problems, we must successively change to a circular economy from a linear economy. The circular economy has the concept of an extended value chain in recovery, reuse, remanufacturing, and recycling, instead of discarding after the use of manufactured goods. New business models of circular economy have been realized to save the earth ecology and sustainable developing society in serious recognition of the linear economy system. New business models are established by creating a vision and developing a program, and by renovating technology, law, and financial support through a worldwide government policy.

Retrospective analysis of the urban inundation and the impact assessment of the flood barrier using H12 model (H12 모형을 이용한 도시침수원인 및 침수방어벽의 효과 분석)

  • Kim, Bomi;Noh, Seong Jin;Lee, Seungsoo
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.5
    • /
    • pp.345-356
    • /
    • 2022
  • A severe flooding occured at a small urban catchment in Daejeon-si South Korea on July 30, 2020 causing significant loss of property (inundated 78 vehicles and two apartments) and life (one casualty and 56 victims). In this study, a retrospective analysis of the inundation event was implemented using a physically-based urban flood model, H12 with high-resolution data. H12 is an integrated 1-dimensional sewer network and 2-dimensional surface flow model supported by hybrid parallel techniques to efficiently deal with high-resolution data. In addition, we evaluated the impact of the flooding barriers which were installed after the flood disaster. As a result, it was found that the inundation was affected by a combination of multiple components including the shape of the basin, the low terrain of the inundation area located in the downstream part of the basin, and lack of pipe capacity to drain discharge from the upstream during heavy rain. The impact of the flooding barriers was analyzed by modeling with and without barriers on the high-resolution terrain input data. It was evaluated that the flood barriers effectively lower the water depth in the apartment complex. This study demonstrates capability of high-resolution physically-based urban modeling to quantitatively assess the past inundation event and the impact of the reduction measures.