• Title/Summary/Keyword: double sequence

Search Result 305, Processing Time 0.025 seconds

Design parameters on the fatigue characteristics of a co-cured double lap joint (양면겹치기 동시경화조인트의 피로특성에 영향을 미치는 설계변수에 관한 연구)

  • 신금철;이정주
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.05a
    • /
    • pp.5-8
    • /
    • 2002
  • The use of the co-cured joining method for composite structures is attractive due to several benefits. However, since the design stress level in cyclic loads is often smaller than the joint strength obtained from the static tensile load test, it is important to establish proper fatigue design criteria. Although some researchers have reported on co-cured joints, there are only a few papers published on the fatigue characteristics of co-cured joints. In this paper, the effect of bond parameters on the fatigue characteristics of a steel-composite co-cured double lap joint under cyclic tensile loads was experimentally investigated. We considered the surface roughness of the steel adherend and the stacking sequence of the composite adherend as bond parameters. A fatigue failure mechanism of the co-cured double lap joint was explained systematically by investigating the surfaces of failed specimens.

  • PDF

Anti-islanding Detection Method for BESS Based on 3 Phase Inverter Using Negative-Sequence Current Injection (역상분 전류 주입을 적용한 3상 인버터 기반 BESS의 단독 운전 검출 방법)

  • Sin, Eun-Suk;Kim, Hyun-Jun;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.9
    • /
    • pp.1315-1322
    • /
    • 2015
  • This paper proposes an active islanding detection method for the BESS (Battery Energy Storage System) with 3-phase inverter which is connected to the AC grid. The proposed method adopts the DDSRF (Decoupled Double Synchronous Reference Frame) PLL (Phase Locked-Loop) so that the independent control of positive-sequence and negative-sequence current is successfully carried out using the detected phase angle information. The islanding state can be detected by sensing the variation of negative-sequence voltage at the PCC (Point of Common Connection) due to the injection of 2-3% negative-sequence current from the BESS. The proposed method provides a secure and rapid detection under the variation of negative-sequence voltage due to the sag and swell. The feasibility of proposed method was verified by computer simulations with PSCAD/EMTDC and experimental analyses with 5kW hardware prototype for the benchmark circuit of islanding detection suggested by IEEE 1547 and UL1741. The proposed method would be applicable for the secure detection of islanding state in the grid-tied Microgrid.

STATISTICAL CONVERGENCE OF DOUBLE SEQUENCES OF COMPLEX UNCERTAIN VARIABLES

  • DATTA, DEBASISH;TRIPATHY, BINOD CHANDRA
    • Journal of applied mathematics & informatics
    • /
    • v.40 no.1_2
    • /
    • pp.191-204
    • /
    • 2022
  • This paper introduces the statistical convergence concepts of double sequences of complex uncertain variables: statistical convergence almost surely(a.s.), statistical convergence in measure, statistical convergence in mean, statistical convergence in distribution and statistical convergence uniformly almost surely(u.a.s.).

Evaluation of sequence tracking methods for Compton cameras based on CdZnTe arrays

  • Lee, Jun;Kim, Younghak;Bolotnikov, Aleksey;Lee, Wonho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.4080-4092
    • /
    • 2021
  • In this study, the performance of sequence tracking methods for multiple interaction events in specific CdZnTe Compton imagers was evaluated using Monte Carlo simulations. The Compton imager consisted of a 6 × 6 array of virtual Frisch-grid CZT crystals, where the dimensions of each crystal were 5 × 5 × 12 mm3. The sequence tracking methods for another Compton imager that consists of two identical CZT crystals arrays were also evaluated. When 662 keV radiation was incident on the detectors, the percentages of the correct sequences determined by the simple comparison and deterministic methods for two sequential interactions were identical (~80%), while those evaluated using the minimum squared difference method (55-59%) and Three Compton method (45-55%) for three sequential interactions, differed from each other. The reconstructed images of a 662 keV point source detected using single and double arrays were evaluated based on their angular resolution and signal-to-noise ratio, and the results showed that the double arrays outperformed single arrays.

RIESZ TRIPLE ALMOST LACUNARY χ3 SEQUENCE SPACES DEFINED BY A ORLICZ FUNCTION-I

  • SUBRAMANIAN, N.;Esi, Ayhan;AIYUB, M.
    • Journal of applied mathematics & informatics
    • /
    • v.37 no.1_2
    • /
    • pp.37-52
    • /
    • 2019
  • In this paper we introduce a new concept for Riesz almost lacunary ${\chi}^3$ sequence spaces strong P - convergent to zero with respect to an Orlicz function and examine some properties of the resulting sequence spaces. We introduce and study statistical convergence of Riesz almost lacunary ${\chi}^3$ sequence spaces and some inclusion theorems are discussed.

Morava K- theory of the double loop spaces of quaternionic stieffel manifolds

  • Park, Younggi
    • Bulletin of the Korean Mathematical Society
    • /
    • v.34 no.3
    • /
    • pp.359-370
    • /
    • 1997
  • In this paper we get the Morava K-theory of the double loop spaces of quarternionic Stiefel manifolds for an odd prime p by computing the Atiyah - Hirzebruch spectral sequence. We also get the homology with Z/(p) coefficients and analyze p torsion in the homology with Z coefficients.

  • PDF

TORSION IN THE HOMOLOGY OF THE DOUBLE LOOP SPACES OF COMPACT SIMPLE LIE GROUPS

  • Choi, Young-Gi;Yoon, Seong-Hee
    • Journal of the Korean Mathematical Society
    • /
    • v.39 no.1
    • /
    • pp.149-161
    • /
    • 2002
  • We study the torsions in the integral homology of the double loop space of the compact simple Lie groups by determining the higher Bockstein actions on the homology of those spaces through the Bockstein lemma and computing the Bockstein spectral sequence.

MARCINKIEWICZ-TYPE LAW OF LARGE NUMBERS FOR DOUBLE ARRAYS

  • Hong, Dug-Hun;Volodin, Andrei I.
    • Journal of the Korean Mathematical Society
    • /
    • v.36 no.6
    • /
    • pp.1133-1143
    • /
    • 1999
  • Chaterji strengthened version of a theorem for martin-gales which is a generalization of a theorem of Marcinkiewicz proving that if $X_n$ is a sequence of independent, identically distributed random variables with $E{\mid}X_n{\mid}^p\;<\;{\infty}$, 0 < P < 2 and $EX_1\;=\;1{\leq}\;p\;<\;2$ then $n^{-1/p}{\sum^n}_{i=1}X_i\;\rightarrow\;0$ a,s, and in $L^p$. In this paper, we probe a version of law of large numbers for double arrays. If ${X_{ij}}$ is a double sequence of random variables with $E{\mid}X_{11}\mid^log^+\mid X_{11}\mid^p\;<\infty$, 0 < P <2, then $lim_{m{\vee}n{\rightarrow}\infty}\frac{{\sum^m}_{i=1}{\sum^n}_{j=1}(X_{ij-a_{ij}}}{(mn)^\frac{1}{p}}\;=0$ a.s. and in $L^p$, where $a_{ij}$ = 0 if 0 < p < 1, and $a_{ij}\;=\;E[X_{ij}\midF_[ij}]$ if $1{\leq}p{\leq}2$, which is a generalization of Etemadi's marcinkiewicz-type SLLN for double arrays. this also generalize earlier results of Smythe, and Gut for double arrays of i.i.d. r.v's.

  • PDF

Fault Line Detection Methodology for Four Parallel Lines on the Same Tower

  • Li, Botong;Li, Yongli;Yao, Chuang
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1217-1228
    • /
    • 2014
  • A method for faulted line detection of four parallel lines on the same tower is presented, based on four-summing and double-differential sequences of one terminal current. Four-summing and double-differential sequences of fault current can be calculated using a certain transformation matrix for parameter decoupling of four parallel transmission lines. According to fault boundary conditions, the amplitude and phase characteristics of four-summing and double-differential sequences of fault current is studied under conditions of different types of fault. Through the analysis of the relationship of terminal current and fault current, a novel methodology for fault line detection of four parallel transmission line on the same tower is put forward, which can pick out the fault lines no matter the fault occurs in single line or cross double lines. Simulation results validate that the methodology is correct and reliable under conditions of different load currents, transient resistances and fault locations.

ON ALGEBRA OF LACUNARY STATISTICAL LIMIT OF DOUBLE SEQUENCES IN INTUITIONISTIC FUZZY NORMED SPACE

  • SHAILENDRA PANDIT;AYAZ AHMAD
    • Journal of applied mathematics & informatics
    • /
    • v.41 no.3
    • /
    • pp.541-552
    • /
    • 2023
  • In 2005, Patterson studied lacunary statistical convergence of double sequences of real numbers and, in 2009, Mursaleen introduced notion of lacunary statistical convergence of single sequences in intuitionistic fuzzy normed space. The current work intends to investigate the lacunary statistical convergence of double sequences and some significant conclusions on the algebra of the lacunary statistical limit of double sequences in intuitionistic fuzzy normed space. In addition, we have studied some examples to support the definitions.