The Study of Chanel in Coutume Jewelry (샤넬의 커스튬 주어리에 관한 연구)

  • 유송옥
    • Journal of the Korean Society of Costume
    • /
    • v.32
    • /
    • pp.45-56
    • /
    • 1997
  • The purpose of this study was to investigate the relationship between Chanel design and her Costume jewelry in 1920's-1930's through documentary studies. According to the study the result was as follows: 1. Chanel's esthetic in the field of Fashion Design bore the double stamp of "elegance" and 'simplicity' 2. Chanel changed the concept of costume jewelry. Chanel's great innovation was that she let 'fake' jewels always keep the intrinsic value of 'real' ones. 3. The simplicity of her perfectly tailored suit was Paradoxically overwhelmed by a fan-tastic array of jewels. The relationhship be-tween Chanel design and her costume jewelry was not able to be seperated. Chanel was a fashion leader fifty years ago and the name "Chanel" will be at the forefornt of fashon fifty years from now. The image of quality will always remain the same in the futures.

  • PDF

A Study on the Velocity Characteristics of the Spray Formed by Two Impinging Jets (충돌 제트로 형성되는 분무의 속도 특성에 대한 연구)

  • Choo, Yeon-Jun;Oh, Dai-Jin;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 2001
  • In this study, the velocity characteristics of liquid elements formed by two impinging jets is analysed using double pulse image capturing technique. For the droplets formed by low speed impinging jets, the droplet velocities are higher with smaller azimuthal and impingement angle. The maximum droplet velocities are about 25 % lower than jet velocity. With an increase of azimuthal angle, the shedding angles increases but remains lower than azimuthal angle. The velocities of ligaments formed by high speed impinging jets gradually decreases with an increase of azimuthal angle. The maximum ligament velocities are about 40% lower than jet velocity. Higher impingement angles produce lower ligament velocities. The shedding angles of ligament almost increases with the same value of azimuthal angle, which implies that the moving direction of ligaments is radial from the origin as the impingement point.

  • PDF

Parametric Analysis of Digital Particle Holography for Spray Droplets (분무 액적을 위한 디지털 입자 홀로그래피의 파라미터 해석)

  • Yang, Yan;Kang, Bo-Seon
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.191-197
    • /
    • 2007
  • This study presents in-line digital particle holography and its application to spray droplets to measure the characteristics of spray droplets. Several important parameters at the time of hologram recording such as the object distance and the region of laser beam used were verified. The correlation coefficient method with important parameters such as the reconstruction interval and the correlation interval was used for determination of the focal planes of particles. The optimal values of all these parameters are obtained by either numerical simulation of holograms or experiments. Using these optimal parameters, double pulse digital spray holograms in a short time interval were recorded with the synchronization system for the time control. The spatial positions of droplets that are used for the evaluation of the three dimensional droplet velocities can be easily located, which proves the feasibility of the digital holographic technology for measurements of several important features of spray droplets.

  • PDF

Second-Order Wave Resistance Calculation of Thin-Ship (얇은 배에 대한 고차 조파저항 계산)

  • Shin-Hyoung,Kang
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.16 no.3
    • /
    • pp.35-47
    • /
    • 1979
  • Wave resistance of a parabolic thin ship, with its boundary layer and wake taken into account, was calculated up to second order. In addition to the double-model source distribution on the centerplane, image sources of the wave potential were calculated to keep the body introduced boundary condition undisturbed. Boundary layer and wake effects on the wave-making resistance were included by generating an irrotational flow which matches that exterior to the boundary layer and wake. For this purpose, the boundary layer and wake were calculated. The wave resistance refined with second-order corrections are found to be very important for wave resistance calculations even at moderate Froude numbers($Fr=0.2{\sim}0.3$). Wave-potential corrections are dominate around the bow. On the other hand, Viscosity plays and important role at the stern with its boundary layer and wake development.

  • PDF

A design of single side-band filter for millimeter wave using martin-puplett interferometer (Martin-puplett 간섭계를 이용한 밀리미터파 대역의 단측파대 여파기 설계)

  • 한석태;김효령;이창훈;박종애;정현수;김광동;김태성;박동철
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.4
    • /
    • pp.98-105
    • /
    • 1996
  • The design method of 85 GHz-115 GHz band single side-band filter using the principle of martin-puplett inteferometer is described. It has been designed by this method and also manufactured and tested. From the test results, not only the ratio of image singal rejection of 19 dB is obtained, but also the theoretical and experimental results of center frequency of pass-band and rejection-band show the validity of the theory. This manufactured filter was installed on 100GHz band SiS (superconductor insulator superconductor ) receiver for observing cosmic radio waves and tested. We found that this filter can be used a single side-band as well as double side-band mode. The design method which is presented in this paper can be used a single side-band filter for a heterodyne type sub-milimeter wave receiver.

  • PDF

K-Band Low Noise Receiver Module Using MMIC Technology

  • Yu, Kyung-Wan;Uhm, Man-Seok;Yom, In-Bok;Chang, Dong-Pil;Lee, Jae-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.1
    • /
    • pp.110-115
    • /
    • 2000
  • A K-band GaAs MMIC receiver module has been developed using 0.15 ${\mu}{\textrm}{m}$ HEMT technology process. It incorporates two front end low noise amplifiers, a double balanced diode mixer, and filters. The RF input frequency ranges 20.1 to 21 GHz and the IF output 1.1 to 2 GHz. Test results show an overall conversion gain of more than 27 dB, and less than a 2.2 dB noise figure. The image-rejection ratio greater than 21 dB has been obtained. The isolation between RF and IF ports is better than 27 dB, and between LO and IF is more than 50 dB.

  • PDF

A Study on Residence S (언제나 쉼이 있는 주거)

  • Yeon, Sook-Hwang
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2004.11a
    • /
    • pp.175-176
    • /
    • 2004
  • Housing culture has rapidly changed since apartments were first introduced in the 1970's. Among our living spaces, particularly, the kitchen reflects our lifestyle and its changes are more remarkable. Activities in kitchen areas include a diverse range of behaviors such as greeting guests, conversation, and family gathering besides cooking and dining. kitchen areas would not be the dedicated housewives' area, but rather a space for all family members. Kitchen areas become a 'living center' where all family members get together and have various family activity. This housing project was designed for the double income family who is consisted of 4 persons. The total area of Apt was 237.6M2. A residence is always comfortable, resting, and consistent for the family. Intimacy image, functional equipments and space, healthy materials were used for this project.

  • PDF

Myocardial viability in acute myocardial infarction: Cardiac MR imaging vs T1 - 201 myocardiac spect

  • 김혜선;박충기;박동우;김용수;김영선;최요원;전석철;서흥석;함창곡
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.134-134
    • /
    • 2002
  • 목적: 심근경색의 가역성 여부 판단시 cardiac MR imaging(CMRI)와 myocardial SPECT의 정확성을 비교하기 위하여 대상 및 방법: 흉통을 주소로 내원한 환자 중 CMRI와 SPECT를 시행한 17를 대상으로 역행적으로 조사하였다. CMRI는 double and triple inversion recovery image(IR)에서 심벽의 고신호강도, 2D-FIESTA에서 심기능 분석을 조사하였다. 이어 gadopentetate를 주입하여 확산스캔에서 확산결손을 조사하였다. 연속하여 gadopentetate를 더 주입 후 5분 후 지연심근강조영상을 얻어 지연조영증강 유무와 미세혈류 폐쇄를 조사하였다. SPECT는 아데노신으로 stress 스캔을 얻은 후 T1-201을 재주사 후 rest 스캔하여 확산결손과 재분배를 조사하여 가역성을 판단하였다.

  • PDF

A Background Subtraction Algorithm for Fence Monitoring Surveillance Systems (담장 감시 시스템을 위한 배경 제거 알고리즘)

  • Lee, Bok Ju;Chu, Yeon Ho;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2015
  • In this paper, a new background subtraction algorithm for video based fence monitoring surveillance systems is proposed. We adopt the sampling based background subtraction technique and focus on the two main issues: handling highly dynamic environment and handling the flickering nature of pulse based IR (infrared) lamp. Natural scenes from fence monitoring system are usually composed of several dynamic entities such as swaying trees, moving water, waves and rain. To deal with such dynamic backgrounds, we utilize the confidence factor for each background value of the input image. For the flickering IR lamp, the original sampling based technique is extended to handle double background models. Experimental results revealed that our method works well in real fence monitoring surveillance systems.

LOCALIZATION TO THE PRODUCTION OF RADIOGRAPHIC IMAGE (X선상 형성과정에서 위치측정에 관하여)

  • Park T. W.
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.11 no.1
    • /
    • pp.75-78
    • /
    • 1981
  • The diagnostic value of a intra oral film is related to projecting technic and interpretation. The intra-oral film is a single plane representation of a three dimensional object, therefore superimposition is inevitablly present. The purpose of this article is to show how foreign objects in the jaw may be localized. The author used double exposure technics, that are changed angulation of vertical or horizontal to one film. The obtained results are as fallow: 1. In the upper anterior region, the moving distance of the labially impacted reference object was greater than that of the palatally impacted one. 2. In the upper molar region, the moving distance of the mesiobuccal root apex was the greatest and that of palatal root apex was the shortest. 3. In the lower molar region, the change of the alveolar bone level in the buccal side was greater than that of lingual side.

  • PDF