Comparison between Old and New Versions of Electron Monte Carlo (eMC) Dose Calculation

  • Seongmoon Jung;Jaeman Son;Hyeongmin Jin;Seonghee Kang;Jong Min Park;Jung-in Kim;Chang Heon Choi
    • 한국의학물리학회지:의학물리
    • /
    • 제34권2호
    • /
    • pp.15-22
    • /
    • 2023
  • This study compared the dose calculated using the electron Monte Carlo (eMC) dose calculation algorithm employing the old version (eMC V13.7) of the Varian Eclipse treatment-planning system (TPS) and its newer version (eMC V16.1). The eMC V16.1 was configured using the same beam data as the eMC V13.7. Beam data measured using the VitalBeam linear accelerator were implemented. A box-shaped water phantom (30×30×30 cm3) was generated in the TPS. Consequently, the TPS with eMC V13.7 and eMC V16.1 calculated the dose to the water phantom delivered by electron beams of various energies with a field size of 10×10 cm2. The calculations were repeated while changing the dose-smoothing levels and normalization method. Subsequently, the percentage depth dose and lateral profile of the dose distributions acquired by eMC V13.7 and eMC V16.1 were analyzed. In addition, the dose-volume histogram (DVH) differences between the two versions for the heterogeneous phantom with bone and lung inserted were compared. The doses calculated using eMC V16.1 were similar to those calculated using eMC V13.7 for the homogenous phantoms. However, a DVH difference was observed in the heterogeneous phantom, particularly in the bone material. The dose distribution calculated using eMC V16.1 was comparable to that of eMC V13.7 in the case of homogenous phantoms. The version changes resulted in a different DVH for the heterogeneous phantoms. However, further investigations to assess the DVH differences in patients and experimental validations for eMC V16.1, particularly for heterogeneous geometry, are required.

정류기형 다이오드를 이용한 반도체 방사선 검출 장치의 제작과 그 응용에 관한 연구 (The Construction of Solid State Detector System Using Commercially Available Diode and Its Application)

  • 신동오;홍성언;이병용;이명자
    • 한국의학물리학회지:의학물리
    • /
    • 제1권1호
    • /
    • pp.91-95
    • /
    • 1990
  • The solid state detector system was constructed using commercially available rectifier diode for the assessment of quality assurance in radiotherapy. Dosimetry system which consists of the electrometer and the water phanton was used for measuring small field size scanning. The measured results, which had linearity in accordance with variation of radiation dose for gamma-ray of Co- 60 and 6 and 10MV photons of linear accelerator, showed quite linear characteristics within 1% error. The percent depth dose of 10MV photon of Mevatron KD linear accelerator was measured in small field size using diode, and the results were compared with that of using ion chambers. The results show that the difference of percent depth dose between the value of diode and that of ion chamber was negligible in large field size. However, in small size less than 4$\times$4cm, the difference of percent depth dose estimated by diode and ion chamber was 4.7% by extrapolation to 0$\times$0cm. Considering the smaller volume of diode than that of ion chamber, it might be more reliable to use diode for estimating percent depth dose. Above results suggest that diode can be used for routine check such as beam profile, flatness, symmetry and energy

  • PDF

Prediction of drug-Drug Interaction During Oral Absorption of Carrier-Mediated Compounds in Humans

  • Oh, Doo-Man;Gordon L. Amidon
    • Archives of Pharmacal Research
    • /
    • 제17권5호
    • /
    • pp.364-370
    • /
    • 1994
  • A microscopic mass balance approach has been developed to estimate the extent and rate of absorption for camier-mediated comounds. For the case competitive inhibition in the presence of an inhibitor which shares the same camier, the fraction dose absorbed (F) and absorption rate constant ($K_a$) of a drug can be calculated from its concentration profile in the intestinal lumen. Absorption parameters obtained by single-pass perfusion experiments were used in the simultaion of the absorption of some aminopenicilins. Predicted fractions dose absorbed and absorption rate constants of ampicilin and amoxicilin were significantly reduced in the presence of a 6-times higher molar dose of cyclacilin. The drug-drug interactions on the competitive absroption of camier-mediated compounds were determined with regard to F and $K_a$. Predicted decreases in F for some aminopenicilins corrlated well with decrease in the urinary recovery in humans reported in the literature. Predicted decrease in the mean absorption rate constant ($\barK_a$) explain the delays in the time of peak plasma concentration ($T_{max}$) reported in humans.

  • PDF

압박대 재질 비교를 통한 유방촬영의 피폭선량 감소 방안 (Reduction of Exposure Dose of Mammography by Comparison of Compression Paddle Material)

  • 홍동희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.455-460
    • /
    • 2019
  • This study compared the radiation transmission and image quality of polymethylmethacrylate (PMMA), polycarbonate (PC), and carbon, which are common components of the compression plates currently used during breast imaging. In addition to measuring the transmitted dose and the intensity without the use of a compression paddle, the four different compression paddles were evaluated according to the material and thickness of each paddle. Radiation transmittance, maximum intensity, and plot profile type w ere all evaluated for each material, and for each factor evaluated the follow ing order w as noted, from best to w orst: carbon 4 mm, PMMA 3 mm, PMMA 4 mm, and PC 4 mm. It is necessary to study a variety of materials and thicknesses in order to find the optimal combination of material and thickness, because not only does the material have a large influence in reducing the radiation exposure during mammography, but the thickness of the compression plate also has a great influence.

Antihyperlipidemic effects of alcoholic extract of Pongamia pinnata Linn. leaves on high fat diet fed rats

  • Tenpe, CR;Mane, G;Upaganlawar, AB;Ghule, BV;Yeole, PG
    • Advances in Traditional Medicine
    • /
    • 제8권3호
    • /
    • pp.311-315
    • /
    • 2008
  • The objective of the study was to investigate the antihyperlipidemic activity of alcoholic extract of Pongamia pinnata Linn. (PPAE) leaves in rats fed with high fat diet (HFD). PPAE was administered orally in the divided doses of 250 and 500 mg/kg/day for 30 days in HFD fed rats. Body weights were observed and the analysis of serum lipid profile was carried out on day 30. Marked decrease in the body weight, total cholesterol (TC), triglycerides (TG), low density lipoprotein (LDL) and very low density lipoprotein (VLDL) whereas significant increase in the levels of high density lipoprotein (HDL) were observed after treatment with PPAE. However, PPAE in a dose of 250 mg/kg did not show significant (P < 0.05) increase in HDL levels. The PPAE also lowered TC: HDL-c and LDL: HDL-c ratios significantly suggesting it's antihyperlipidemic and cardioprotective potential. The present work reveals that PPAE at the dose of 500 mg/kg/day exhibited significant (P < 0.01) antihyperlipidemic effects.

Impact of the Respiratory Motion and Longitudinal Profile on Helical Tomotherapy

  • Park, So Hyun;Choi, Jinhyun;Kim, JinSung;Ahn, Sohyun;Kim, Min Joo;Lee, Ho;Choi, Seo Hee;Park, Kwangwoo
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.1-7
    • /
    • 2018
  • The $TomoTherapy^{(R)}$ beam-delivery method creates helical beam-junctioning patterns in the dose distribution within the target. In addition, the dose discrepancy results in the particular region where the resonance by pattern of dose delivery occurs owing to the change in the position and shape of internal organs with a patient's respiration during long treatment times. In this study, we evaluated the dose pattern of the longitudinal profile with the change in respiration. The superior-inferior motion signal of the programmable respiratory motion phantom was obtained using AbChes as a four-dimensional computed tomography (4DCT) original moving signal. We delineated virtual targets in the phantom and planned to deliver the prescription dose of 300 cGy using field widths of 1.0 cm, 2.5 cm, and 5.0 cm. An original moving signal was fitted to reflecting the beam delivery time of the $TomoTherapy^{(R)}$. The EBT3 film was inserted into the phantom movement cassette, and static, without the movement and with the original movement, was measured with signal changes of 2.0 s, 4.0 s, and 5.0 s periods, and 2.0 mm and 4.0 mm amplitudes. It was found that a dose fluctuation within ${\pm}4.0%$ occurred in all longitudinal profiles. Compared with the original movement, the region of the gamma index above 1 partially appeared within the target and the border of the target when the period and amplitude were changed. Gamma passing rates were 95.00% or more. However, cases for a 5.0 s period and 4.0 mm amplitude at a field width of 2.5 cm and for 2.0 s and 5.0 s periods at a field width of 5.0 cm have gamma passing rates of 92.73%, 90.31%, 90.31%, and 93.60%. $TomoTherapy^{(R)}$ shows a small difference in dose distribution according to the changes of period and amplitude of respiration. Therefore, to treat a variable respiratory motion region, a margin reflecting the degree of change of respiration signal is required.

속중성자선의 선량분포에 관한 연구 (Fast Neutron Beam Dosimetry)

  • 지영훈;이동한;류성렬;권수일;신동오;박성용
    • 한국의학물리학회지:의학물리
    • /
    • 제8권2호
    • /
    • pp.45-57
    • /
    • 1997
  • 속중성자선을 임상에 이용하기 위해서는 속중성자선의 선량 및 선량분포를 정확히 측정하는 것이 매우 중요하다. 현재 속중성자선의 측정법은 크게 나누어 American Associations of Physicists in Medicine, European Clinical Neutron Dosimetry Group 및 International Commission on Radiation Units and Measurements에 의하여 제시되고 있으나 측정의 복잡함으로 인하여 서로 약간씩 다른 방법을 제시하고 있다. 따라서 본 연구에서는 중성자 치료장치에서 방출되는 속중성자선의 방출선량 및 물질 내 선량분포 등의 측정을 통하여 독자적인 측정기술을 확보하고, 우리 실정에 알맞은 표준측정법을 개발하고자 하였다. 속중성자선의 선량 및 물질 내 선량 분포 측정에는 조직등가물질인 A-150 플라스틱으로 제작된 IC-17 및 IC-18 이온함, 마그네슘으로 제작된 IC-17M 이온함, TE 기체, Ar 기체 및 RDM 2A electrometer 등을 사용하였다. 연구 결과 중성자선에 혼합되어 있는 ${\gamma}$선의 오염도는 기준조사면 깊이 5cm에서 약 13% 로 나타났으며, 깊이가 깊어질수록 증가하였다. 기준 조사면에 대하여 중심축선상의 최대 선량 깊이는 1.32cm 이었으며, 50% 선량 깊이는 14.8cm로 나타났다. 표면선량율은 전 조사면에 걸쳐서 41.6%~54.1%이었으며 조사면가 커질수록 증가하였다. Beam profile 은 2.5cm 깊이에서 7.5% 정도 horne effect가 나타났으며 10cm 깊이에서 가장 평탄하였다.

  • PDF

Six-Dual 전자선 조사면에 의한 전신 피부 조사의 선량 특성 (Dose Characteristics of Total-Skin Electron-Beam Irradiation with Six-Dual Electron Fields)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제16권3호
    • /
    • pp.337-345
    • /
    • 1998
  • 목적 : 전신피부의 수 mm 깊이에 한정된 피부 종양의 전신전자선조사에서 균등선량을 얻기위해, 원거리 전자선조사면에 대한 선량특성을 얻고 상하6방향조사에 의한 전신피부선량분포를 조사하였다. 대상 및 방법 : 전신조사를 위한 실험적 선량분포는 전자선 타켓-피부간 거리 300 cm에서, 크기가 105*105 $cm^2$ (콜리메-터 35*35 $m^2$, TSD 100 cm) 인 조사면으로 4 MeV 전자선의 심부선량률, 공간선량분포, 에너지감쇠에 의한 선량률 변화 등의 선량특성이 정해졌다. 환자는 상하 6방향조사가 이루어지는 동안 안정된 위치를 유지하기 위하여 양손을 치켜들고 기둥막대를 잡을 수 있는 발판에 위에 표시해둔 위치에 서게 하였다. 4 MeV 전자선 에너지를 감쇠 시켜 산란선고 피부선량을 높이기 위해 전자선 통로상 환자 전면의 20 cm 거리에 0.5 cm 두께의 산란체인 아크릴판을 설치하였다. 전신피부의 흡수선량은 테프론혼합 CaSO4:Dy 열형광소자 (1 mm 직경 * 6 mm 길이)를 전신 74 곳에 부착하여 분할조사면에 의한 합성선량을 평가하였다. 결과 : 전자선 타켓-피부간 거리 300 cm에서 얻어진 105*105 $cm^2$ 의 큰 조사면의 선량 반치폭은 130 cm 였으며, 80$\%$ 폭은 86 cm 로 나타났으며, 두 조사면을 FWHM 만큼 이동하여 두 조사면을 25 cm 띄워 조사한 합성선량분포에서 선량률이 $100\pm10\%$ 인 균등조사면의 폭은 186 cm 로 확장되었다. 인체전면 20 cm 위체에 0.5 cm 아크릴판을 삽입한 결과, 4 MeV 전자선은 최대선량점 5 mm, 80$\%$ 깊이가 7 mm, 50$\%$ 깊이는 10.7 mm를 보여 감쇠된 전자선의 평균에너지는 2.5 MeV 였다. 큰 조사면의 선속 중심에서 50 cm 떨어진 위치의 심부선량률은 중심선속의 심부선량과 거의 동일 값을 보였다. 전신피부조사에 의한 환자의 선량분포는 인체의 돌출부와 굴곡부분을 제외하고는 비교적 균등한 선량이 도달되었으며, 돌출부와 분할조사면이 잘 이루어지지 않는 중첩조사부위는 각각 30$\%$ 와 60-100$\%$ 의 과다선량이 도달되어 치료중 차폐가 불가피한 반면, 인체구조상 전자선이 가리워지는 두정부, 회음부 및 대퇴부 내측은 선량이 거의 도달 되지 않는 곳이 생겨지므로 부가적 조사가 필요함을 알 수 있었다. 결론 : 전신피부조사는 2-3 MeV의 저에너지 전자선빔에 의해 피하 수 mm 깊이에 80$\%$ 의 선량을 도달시킬 수 있으며, 높은 에너지에서는 흡수체를 이용하여 적정에너지를 얻을 수 있다. 전신피부조사에서 전신균등선량은 전자선을 상하 각각 6문조사로 고정분할 조사하는 경우 전자선이 가리워지는 부위를 제외하고 대개 $\pm10\%$ 의 선량오차범위에 들었으나, 돌출부위의 선량과다부위에는 차폐가 필요하였으며, 전자선이 가리워지는 부위는 부가치료를 통해 임상에 적합한 균등선량분포를 얻을 수 있다.

  • PDF

Co-60에 의한 전신조사시 선량분포 (Dose Distribution of Co-60 Photon Beam in Total Body Irradiation)

  • Kang, Wee-Saing
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.109-120
    • /
    • 1991
  • 골수이식을 받게 될 환자의 이상 골수를 완전히 죽이기 위해 MV 정도의 선질의 광자선에 의한 전신방사선요법이 시행되고 있다. 국소방사선요법에 이용되고 있는 방사선치료장치에 의한 일상적인 방법으로 환자의 전선에 걸쳐 방사선을 조사하기에는 조사면의 크기가 훨씬 미치지 못한다. 그래서 환자의 전선에 걸쳐 방사선을 조사할 수 있는 방법이 개발되어야 한다. 방사선 전신조사를 위한 여건이 병원에 따라 다를 것이기 때문에 병원에 따라 독특한 방법이 개발될 수 있다. 서울대학교병원에서는 코발트치료기 만이 두부를 기울일 수 있어서 전신조사에 이용될 수 있다. 코발트치료기의 두부를 밖으로 90$^{\circ}$ 기울일 때 선축은 수평이고 또한 맞은편 벽과 직각이 된다. 이 때 선원에서 맞은편 벽가지 거리는 319cm 이였다. 벽에서 환자의 중앙시상면까지 간격을 40cm라고 가정할 때, 중앙시상면에서 명목상 최대 조사면 크기가 122cm$\times$122em 이였고, 조사선량 분포를 측정한 결과로는 130cm$\times$129cm 이였으며 상하방향에서는 대칭이 아니였다. 환자가 쭈그리고 앉은 자세를 취한다면 조사면의 크기는 전신조사를 시행할 수 있을 정도로 충분히 크다. 환자 좌우폭의 평균을 30cm 라고 가정하고, 중앙시상면에서 선원쪽 15cm 위치에 기준표면 (SSD는 264cm, 명목상 조사면 크기 115.5cm$\times$155.5cm)을 두고 단면의 크기가 25cm$\times$25cm이고 두께가 30cm 인 폴리스티렌 팬톰에서 평판형 전리함으로 PDD를 측정하였다. 최대선량점의 깊이는 0.3cm 이였고 표면선량율은 82%, 50% 깊이는 16.9cm였다. 대향조사시 선축상 선량분포는 중점의 선량에서 10%이내로 일치하였다. SCD를 279cm. 최대 조사면, 기준깊이 15cm 에 대한 TPR 을 폴리스티렌 팬톰에서 깊이 10cm 에서 20cm 에 걸쳐 측정하였다 . 측정범위에서 TPR 은 직선성을 보였다. 인체팬톰의 최대 전단면(coronal plane) 에 있는 각 구멍에 TLD 조각을 넣고, 코발트 선원에서 팬톰의 시상면까지 거리를 279cm 되게 하고 선축은 팬톰의 27번 절편과 28번 절편의 접변과 최대 전단면의 교차선과 일치시켜 양방향에서 15분씩 조사하여 전단면에서 선량을 측정하였다. 팬톰내 선축상 중앙점의 선량을 기준으로 다른 부위의 선량을 비교하였다. 두경부와 복부, 폐의 하반에서 선량의 차이는 $\pm$ 10% 이내였고, 폐의 상반과 어깨와 골반 부위에서 선량은 10%이상 저선량을 보였다. 특히 어깨부위에는 30%이상 저선량을 보였다. 이로부터 서울대병원과 유사한 조건에서 코발트로 전신조사하는 경우에는 폐나 두경부에 대응하는 조직보상체를 이용하기보다는 어깨부위에 선량을 추가하는 것이 바람직할 것이라고 생각한다.

  • PDF

Effects of Oxidized Tallow on the Rabbit Serum Lipids and Antioxidant Activity of the In-vitro Lipids

  • Zeb, Alam;Rahman, Waheed Ur
    • Toxicological Research
    • /
    • 제28권3호
    • /
    • pp.151-157
    • /
    • 2012
  • This paper describes the effects of thermally oxidized tallow on the serum lipids profile and radical scavenging activity (RSA) of the lipids extracted from the different tissues of the rabbits. Tallow was thermally oxidized at $130^{\circ}C$ for 9, 18, 27, 36 and 45 h respectively. Thermally oxidized tallow was fed to the local strain of Himalayan rabbits for one week. Results show that oxidation increases the formation of hydroperoxides and decrease the level of radical scavenging activity of the tallow. The rabbit serum lipids profile showed a dose dependent increase in triglyceride, total cholesterol and LDL-cholesterol. However, no statistically significant increase was observed in the HDL-cholesterol with an increase of oxidation time. Serum glucose and rabbits body weight decrease significantly (p < 0.05) and was highly correlated with the serum lipids profile. The percent RSA of the lipids extracted from the liver, brain and muscles tissues showed a significant decrease with respect to 0.5, 1.0 and 1.5 g/body weight as well as oxidation time. Data suggests that thermal oxidation and use of thermally oxidized beef tallow is harmful and therefore an alternative way of cooking should be used.