DOI QR코드

DOI QR Code

Reduction of Exposure Dose of Mammography by Comparison of Compression Paddle Material

압박대 재질 비교를 통한 유방촬영의 피폭선량 감소 방안

  • Hong, Dong-Hee (Department of Radiological Science, Shinhan University)
  • 홍동희 (신한대학교 방사선학과)
  • Received : 2019.12.13
  • Accepted : 2019.12.26
  • Published : 2019.12.31

Abstract

This study compared the radiation transmission and image quality of polymethylmethacrylate (PMMA), polycarbonate (PC), and carbon, which are common components of the compression plates currently used during breast imaging. In addition to measuring the transmitted dose and the intensity without the use of a compression paddle, the four different compression paddles were evaluated according to the material and thickness of each paddle. Radiation transmittance, maximum intensity, and plot profile type w ere all evaluated for each material, and for each factor evaluated the follow ing order w as noted, from best to w orst: carbon 4 mm, PMMA 3 mm, PMMA 4 mm, and PC 4 mm. It is necessary to study a variety of materials and thicknesses in order to find the optimal combination of material and thickness, because not only does the material have a large influence in reducing the radiation exposure during mammography, but the thickness of the compression plate also has a great influence.

Keywords

References

  1. Ministry of Health & Welfare. Annual report of cancer statistics in Korea in 2013, Korea; 2015.
  2. Park JY. A study on the actual conditions and characteristics of mammographic units in some area. Department of Radiological Science, Graduate Sch ool of Life Sciences, Cath olic University of Pusan; 2010.
  3. Kang BS. Radiographic imaging. Daihak Publishing Company; 2014.
  4. Ministry of Health and Welfare, Korea Food & Drug Administration, The Korean Society of Radiology, The Korean Radiological Technologists Association. Patient dose recommendations guidelines in mammography. Radiation Safety Management Series. 2008;16:22.
  5. Choi JH, Jeon MJ, Kim YI, Choi JW. A study on radiation dose in mammography. Journal of Korean Society of Radiological Technology. 1981;4(1):31-6.
  6. Lee JS. Dose evaluation using mathematical simulation of radiation exposure body in mammography system. Journal of the Korean Radiological Society. 2014;8(4):155-61. https://doi.org/10.7742/jksr.2014.8.4.155
  7. Hong DH. Evaluation of radiolucent considering the compression paddle materials in mammography. The Korea Contents Association. 2016;4(4):11-6.
  8. Hong DH, Jung HR, Lim ChH, Choi JG, Kim GJ. A study on the compression paddle materials to reduce exposure during mammography. Indian Journal of Science and Technology. 2015;8(26):IPL0466.
  9. Kim YH. Patient exposure dose from medical X-ray examination in Korea. Radiological Technology. 2005;41(1):241-8.
  10. Kim MY, Kim HS. The evaluation of radiation dose by exposure method in digital magnification mammography. Korean Society of Radiological Science, 2012;35(4):293-8.
  11. Faul F, Erdfelder E, Buch ner A, Lang AG, Statistical power analyses using G*Power 3.1 : Tests for correlation and regression analyses. Behavior Research Methods. 2009;41:1149-60. https://doi.org/10.3758/BRM.41.4.1149
  12. Kang SG, Lee EN. Knowledge of radiation protection and the recognition and performance of radiation protection behavior among perioperative nurses. The Journal of Muscle and Joint Health. 2013;20(3):247-57. https://doi.org/10.5953/JMJH.2013.20.3.247
  13. Han EO, Kwon DM. Analysis of the trend of knowledge, attitude and behavior related to radiation safety management: Focused on radiation workers at medical institutions. Journal of Radiation Protection. 2007;30(2):89-96.
  14. Gist ME, Schwoerer C, Rosen B. Effects of alternative training methods on self-efficacy and performance in computer software training. Journal of Applied Psychology. 1989;74(6):884. https://doi.org/10.1037/0021-9010.74.6.884
  15. Yi CJ, Ha SW, Jung HW. Chromosome aberration in peripheral lymphocyte of radiation workers in hospital. J Radiat Prot. 1997;22:227-35.
  16. Hong DH. Analysis of radiation protection, awareness and attitude of radiological technologist in mammography room. Korean Society of Radiological Science. 2017;40(4):557-65.
  17. Kim JM, Lee KS, Kim YH. Correction method of Wiener Spectrum (WS) on digital medical imaging systems. Journal of Radiological Science and Technology. 2009;32(1):17-24.