• 제목/요약/키워드: dose difference

검색결과 1,775건 처리시간 0.028초

어린이 부비동 엑스선 검사에서 검사자의 갑상선 차폐 효과성에 관한 연구 (Study on the Effectiveness of Radiological Technologist's Thyroid Shielding in Pediatric Paranasal Sinus X-ray Examination)

  • 곽창교;권정택;이광제;배일환;김혜정;이소미;이도병
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.197-203
    • /
    • 2024
  • During paranasal sinus X-ray examinations in children, the radiological technologist's thyroid shield is often not implemented to shorten the examination time. This study measured the radiation exposure before and after the implementation of thyroid shielding by analyzing the difference in radiation exposure, the radiological technologist's could receive depending on the actual thyroid shielding. In the left TLD, when thyroid shielding was not performed(N), the radiation exposure dose(mSv) was 2.869 for the depth dose[Hp(10)] and 2.886 for the surface dose[H(3)], and when thyroid shielding was performed(Y), the Hp(10) was 0.033 and the H(3) was 0.034. In the right TLD, when thyroid shielding was not performed(N), the radiation exposure dose was 3.149 for Hp(10) and 3.137 for H(3), and when thyroid shielding was performed, the Hp(10) of (Y) was 0.013 and the H(3) was 0.015. The differences in the overall exposure dose measurement values are all statistically significant (p<0.05). The difference in radiation dose between when thyroid shielding was not performed and when thyroid shielding was performed was more than 99.2% in both cases, indicating a high radiation shielding rate.

전산화단층촬영장치에서 환자피폭선량 (Patient Radiation Exposure Dose in Computed Tomography)

  • 조평곤
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.109-115
    • /
    • 2015
  • 전산화단층촬영장치(computed tomography, CT)을 이용한 검사의 경우 방사선량의 분포가 일반 X선 장치와 차이가 있고 검사로 인한 방사선 피폭이 많은 것으로 알려져 있다. 그러나 검사 결과의 정확성에 대한 신뢰도가 높아 그 이용도는 계속적으로 증가하고 있다. 이와 같은 상황을 고려하여 기존에 발표된 자료를 바탕으로 CT장치, CT검사에서 방사선량, 진단참고준위 그리고 검사 시 방사선량 감소 방안에 대해 알아보았다.

Dosimetric Evaluation of an Automatically Converted Radiation Therapy Plan between Radixact Machines

  • Lee, Mi Young;Kang, Dae Gyu;Kim, Jin Sung
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.153-162
    • /
    • 2020
  • Purpose: We aim to evaluate the accuracy and effectiveness of an automatically converted radiation therapy plan between Radixact machines by comparing the original plan with the transferred plan. Methods: The study involved a total of 20 patients for each randomly selected treatment site who received radiation treatment with Radixact. We set up the cheese phantom (Gammex RMI, Middleton, WI, USA) with an Exradin A1SL ion chamber (Standard Imaging, Madison, WI, USA) and GAFCHROMIC EBT3 film (International Specialty Products, Wayne, NJ, USA) inserted. We used three methods to evaluate an automatically converted radiation therapy plan using the features of the Plan transfer. First, we evaluated and compared Planning target volume (PTV) coverage (homogeneity index, HI; conformity index, CI) and organs at risk (OAR) dose statistics. Second, we compared the absolute dose using an ion chamber. Lastly, we analyzed gamma passing rates using film. Results: Our results showed that the difference in PTV coverage was 1.72% in HI and 0.17% in CI, and majority of the difference in OAR was within 1% across all sites. The difference (%) in absolute dose values was averaging 0.74%. In addition, the gamma passing rate was 99.64% for 3%/3 mm and 97.08% for 2%/2 mm. Conclusions: The Plan transfer function can be reliably used in appropriate situations.

Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상 (Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing)

  • 김민주;조웅;강영남;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제23권1호
    • /
    • pp.62-69
    • /
    • 2012
  • 적응 방사선 치료(Adaptive Radiation Therapy, ART)를 실행하기 위한 매 치료 마다 획득되는 Megavoltage cone-beam CT (MVCBCT) 영상을 이용한 재 선량 계산 과정은 필수적이다. 본 연구의 목적은 intensity 보정 방법을 적용한 MVCBCT 영상 기반의 선량 계산 결과와 kilo-voltage CT (kV CT) 영상 기반의 선량 계산 결과의 비교 및 MVCBCT 영상 기반의 선량계산 정확성의 향상이다. MVCBCT 영상의 intensity 교정을 위해 kV CT와 MVCBCT을 이용하여 12 종류의 전자밀도 바를 제공하는 Cheese 팬텀 영상을 획득하고, Cheese 팬텀 영상의 동일한 전자밀도 바에서 표현되는 kV CT 영상과 MVCBCT 영상의 intensity 관계를 도출하였다. 이후 kV CT, MVCBCT를 이용한 Rando 팬텀 영상을 획득하여 MVCBCT 영상은 3차원 강체 정합을 수행하였고 본 과정을 통해 MVCBCT 영상은 kV CT 영상과 마치 동일한 모달리티에서 획득한 영상과 같은 위치 및 intensity 분포로 변환되었고, MVCBCT 영상의 잡음을 없애기 위한 Gaussian smoothing 필터를 적용하였다. 위의 과정을 거친 MVCBCT 영상을 토대로 intensity 교정을 적용한 영상과, intensity 교정을 적용하지 않은 영상, kV CT영상을 기반으로 방사선 치료 계획 시스템을 이용한 선량 계산을 시행 하였다. 선량 계산의 결과는 선량 분포의 차이 및 Percentage difference로 평가되었다. Intensity 보정을 적용한 MVCBCT 영상의 선량 계산 결과의 경우 kV CT 영상 기반의 선량 계산 결과와의 Percentage difference가 두경부 영상의 경우 1.08%, 흉부 영상의 경우 2.44%였다. 본 연구에서 적용한 intensity 변환을 통해 MVCBCT 영상을 이용한 선량 계산의 정확성이 향상됨을 확인하였고, 본 연구 방법은 실제 선량 계산에 적용 및 사용의 편리성을 확인하였다. 차후 연구 계획도 본 연구 내용에 의해 제안되었다.

인터벤션에서 자동노출제어장치 이용 시 내장형 면적 선량계와 이동형 면적 선량계의 면적선량 비교를 통한 선량계 오차분석과 교정지침 필요성 연구 (Analysis of Dosimeter Error and Need for Calibration Guideline by Comparing the Dose Area of the Built-in Dose Area Product and the Moving Dose Area Product when using Automatic Exposure Controller in Intervention)

  • 최지안;황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제18권11호
    • /
    • pp.508-515
    • /
    • 2018
  • 본 연구는 인터벤션 장비의 자동노출제어장치(Automatic Exposure Controller, AEC) 이용 시 내장형 면적 선량계와 교정된 이동형 면적 선량계의 오차를 분석하여 선량계 교정의 중요성과 교정지침의 필요성을 알아보고자 하였다. 실험방법은 NEMA 팬텀의 메뉴얼에 따라 팬텀을 Thin, Normal, Heavy Adult로 조립하고 내장형 면적 선량계와 이동형 면적 선량계로 면적선량을 측정하였다. 그 결과 모든 두께에서 내장형 면적 선량계가 이동형 면적 선량계보다 나타내는 선량 값이 높았고 두께가 두꺼울수록 그 차이가 커졌다. 또한 각 항목에 대하여 paired t-test를 시행하였고, 그 결과 각 항목은 p<0.05로 유의한 차이가 있었다. 결론적으로 피폭에 많이 노출되는 인터벤션 시술을 고려해 볼 때, 장비의 자동노출제어장치 사용 시 정확한 선량 파악 여부가 중요하고 현재 내장된 면적 선량계에 대한 교정지침이 없으므로 교정지침을 마련하는 것이 필요하다.

최소 효과 용량을 정하는 축차 검정법 (Parametric Sequential Test Procedure to Find the Minimum Effective Dose)

  • 박수진;김동재
    • 응용통계연구
    • /
    • 제22권5호
    • /
    • pp.1033-1046
    • /
    • 2009
  • 신약 개발 연구 또는 임상시험에서 개발된 약이 0용량 대조군과 비교해 유의한 효과 차이가 있어 신체에 반응할 수 있는 최소 복용량을 결정하는데, 이 최소 복용량을 최소 효과 용량(Minimum Effective Dose; MED)이라 한다. 이 논문에서는 최소 효과 용량을 확인하기 위하여 업데이티드 대조군을 이용한 모수적 축차 검정법을 제안하였다. 또한 모의 실험을 통하여 기존의 검정법과 제안한 검정법의 실험유의수준(experimental significance level)과 검정력(power)을 비교하였다.

Comparison of plan dosimetry on multi-targeted lung radiotherapy: A phantom-based computational study using IMRT and VMAT

  • Khan, Muhammad Isa;Rehman, Jalil ur;Afzal, Muhammad;Chow, James C.L.
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3816-3823
    • /
    • 2022
  • This work analyzed the dosimetric difference between the intensity modulated radiotherapy (IMRT), partial/single/double-arc volumetric modulated arc therapy (PA/SA/DA-VMAT) techniques in treatment planning for treating more than one target of lung cancer at different isocenters. IMRT and VMAT plans at different isocenters were created systematically using a Harold heterogeneous lung phantom. The conformity index (CI), homogeneity index (HI), gradient index (GI), dose-volume histogram and mean and maximum dose of the PTV were calculated and analyzed. Furthermore, the dose-volume histogram and mean and maximum doses of the OARs such as right lung, contralateral lung and non GTV were determined from the plans. The IMRT plans showed the superior target dose coverage, higher mean and maximum values than other VMAT techniques. PA-VMAT technique shows more lung sparing and DA-VMAT increases the V5/10/20 values of contralateral lung than other VMAT and IMRT techniques. The IMRT technique achieves highly conformal dose distribution to the target than other VMAT techniques. Comparing to the IMRT plans, the higher V5/10/20 and mean lung dose were observed in the contralateral lung in the DA-VMAT.

SD(Sprague-Dawley) 랫드를 이용한 신바로 약침의 4주 반복 근육투여 독성시험 (Multiple-dose Intramuscular Toxicity Study of Shinbaro Pharmacopuncture in Sprague-Dawley Rats over a 4-week period)

  • 이진호;하인혁;김미령;김민정;이재웅;이인희;정화진;김은지
    • Journal of Acupuncture Research
    • /
    • 제32권4호
    • /
    • pp.77-89
    • /
    • 2015
  • Objectives : To evaluate the safety of multiple-dose intramuscular Shinbaro Pharmacopuncture in male and female Sprague-Dawley(SD) rats over a period of 4 weeks(12 sessions). Methods : In order to test the safety of multiple-dose intramuscular Shinbaro Pharmacopuncture we used 40 healthy male and female 6-week old SD rats(male weight 171.79~196.37 g, female weight 127.93~146.43 g). Shinbaro Pharmacopuncture was administered intramuscularly to male and female SD rats at doses of 4.6 (low dose group, n=10), 9.2 (moderate dose group, n=10), and 18.5 mg/kg(high dose group, n=10), respectively. General symptoms, body weight changes, blood tests, biochemical testing, necropsy, organ weight and histopathogical findings were examined over a 4-week period. Results : 1. No mortalities or adverse effects were caused by the investigational substance were observed during the study period. 2. There was no significant difference in body weight caused by the the investigational substance across all groups. 3. No significant between-group difference was found to be caused by the investigational substance in blood tests and biochemical testing. 4. No abnormalities were detected by a necropsy examination with the unaided eye at the macro level after treatment with the investigational substance. 5. Difference in organ weight between groups caused by the investigational substance was not found. 6. All groups did not exhibit pathological findings caused by the investigational substance in histopathogical examination. Conclusions : According to these results, Shinbaro Pharmacopuncture has no systemic or organ toxicity with multiple-dose intramuscular administrations in male and female SD rats over a 4-week period (12 sessions). These results imply that no adverse effects are observed at a level (NOAEL) of Shinbaro Pharmacopuncture of 18.5 mg/kg.

입체조형 동적회전조사 방사선치료의 선량 검증 (Dosimetric Verification of Dynamic Conformal Arc Radiotherapy)

  • 김태현;신동호;이두현;박성용;윤명근;신경환;표홍렬;김주영;김대용;조관호;양대식;김철용
    • 한국의학물리학회지:의학물리
    • /
    • 제16권4호
    • /
    • pp.166-175
    • /
    • 2005
  • 입체조형 동적회전조사 방사선치료(Dynamic Conformal Arc Radiotherapy, DCAR)에서 필름 선량계를 이용한 선량검증시 필름 회전중심점 이동 보정값을 최적화법으로 구하고 최적화 후 DCAR에 대한 선량 검증의 정량적 허용기준을 제시하고자 하였다. 정위방사선치료를 시행했던 7명의 전이성 뇌암 환자에서 DCAR 치료계획을 시행하고 필름 선량계로 선량을 측정하였다. 필름 선량계의 가장 큰 계통적 오차 요인인 회전중심점 이동 보정값을 최적화법으로 구하고 치료계획과 필름으로 측정된 선량분포를 비교하여 최적화 전후의 평균 선량오차와 점선량오차가 $5\%$ 이상인 지점의 비율을 얻었다. 모든 환자에서 필름 선량계의 회전중심점 이동 보정값은 1 mm 이내였다. 필름 회전중심점 이동 보정 최적화전, 후로 선량오차 결과를 산출하였다. 최적화 전, 후의 평균 선량오차의 평균은 각각 $1.70{\pm}0.36\%$, $1.34{\pm}0.20\%$이었고 점선량오차가 $5\%$ 이상인 지점 비율의 평균은 각각 $4.54{\pm}3.94\%$, $0.11{\pm}0.12\%$로서 최적화 후 선량오차가 현저히 감소하였다. 본 연구의 결과와 같이 최적화법을 이용한 필름의 회전중심점 이동값을 구하고 최적화 후의 평균 선량오차와 점선량오차가 $5\%$ 이상인 지점의 비율을 구하는 방법은 임상에서 DCAR에 대한 선량 검증 방법으로 유용하게 사용될 수 있을 것으로 기대된다.

  • PDF

가임기 여성의 방사선 치료 시 난소 선량 평가 (Evaluation of Ovary Dose of Childbearing age Woman with Breast cancer in Radiation therapy)

  • 박성준;이영철;김선명;김영범
    • 대한방사선치료학회지
    • /
    • 제33권
    • /
    • pp.145-153
    • /
    • 2021
  • 목 적: 본 연구에서는 가임기 여성의 유방암 방사선 치료 시 난소 선량에 대해 실험을 통하여 평가해보고자 한다. 치료기법에 따른 치료계획시스템에서 계산된 선량과 열형광선량계를 이용한 측정선량을 비교·분석하여 난소 선량을 평가하고 납(Pb) 앞치마의 사용유무에 따른 선량 분석을 통해 임상에서의 유용성을 알아보고자 한다. 대상 및 방법: 측정에는 Rando humanoid phantom을 이용하였고, 치료기법으로는 쐐기필터치료기법, 3차원 입체조형치료, 세기변조방사선치료를 사용하였다. CT simulator를 이용하여 얻은 Rando humanoid phantom 3D 영상의 우측 유방에 처방선량의 95%가 전달될 수 있도록 치료계획을 세웠고, TLD를 Rando hunmanoid phantom의 가상 표적의 표면 및 심부에 삽입하고 방사선을 조사하였다. 측정위치는 치료 중심점과 Rando humanoid phantom의 정중앙을 중심으로 반대쪽 유방으로 2cm 이동한 지점과 치료 중심축 및 하방으로 우측 유방의 경계면에서 5cm, 10cm, 12.5cm, 15cm, 17.5cm, 20cm, 우측 난소 위치의 표면과 중심점을 포함하여 총 9개 지점에서 측정하였다. 치료계획시스템의 선량 비교에서는 쐐기필터치료기법 2가지와 3차원 입체조형치료, 세기변조방사선치료 등 총 4개의 치료 계획을 수립하여 비교하였다. 그리고 TLD를 이용한 측정값 비교는 세기변조방사선치료와 쐐기필터를 이용한 치료를 비교하였고, 납 앞치마의 사용유무에 따라서 세기변조방사선치료의 선량차이를 측정하여 비교·분석하였다. 측정값은 각 포인트마다 3개의 TLD값 평균을 내고 TLD 교정값을 이용하여 환산하였으며 이를 Point dose mean값으로 계산하였다. 치료계획값과 실제 측정값을 비교하기 위해 각 지점마다 절대선량값을 측정하여 %Diff 값으로 계산하였다. 결 과: 치료 중심점인 Point A에서는 치료계획시스템에서 최대 201.7cGy가 나왔고, 실제 TLD 측정값은 최대 200.6cGy가 나왔다. 모든 치료계획시스템에서 유방 경계면으로부터 하방으로 17.5cm 떨어진 지점인 Point G 부터는 0cGy로 계산이 되었다. 실제 TLD 측정 결과 Point G에서는 최대 2.6cGy가 나왔고, 난소선량인 Point J에서는 최대 0.9cGy로 나타났으며 %Diff값은 0.3%~1.3%였다. 납 앞치마의 사용유무에 따른 선량 차이는 최대 2.1cGy에서 최소 0.1cGy로 나타났으며 %Diff값은 0.1%~1.1%였다. 결 론: 치료계획시스템에서 3가지 치료계획에 따른 선량차이는 최저 0.85%에서 최고 2.45%로 큰 격차를 보이지 않았다. 난소에서 Rando humanoid phantom의 치료계획과 실제 측정한 선량차이는 0.9% 이내로 나타났으나 실제 측정에서 조금 더 높게 측정되었다. 이는 치료계획시스템에서 산란선의 영향을 정확하게 반영하지 못하였고, 실제 측정에서는 TLD를 삽입한 상태로 CBCT를 촬영한 선량과 산란선량이 반영된 것으로 사료된다. 납 앞치마의 유무에 따른 선량측정에서 납 앞치마를 사용했을 경우에 치료범위에서 가까운 거리일수록 차폐의 효과가 있었으며, 치료범위에서 15cm 이상 거리가 있는 경우에는 거의 영향을 미치지 않는 것으로 나타났다. 임상적으로 방사선 치료 중에는 임신이나 인공수정을 하기에는 적절하지 않지만, 치료 중 난소에 조사된 선량은 방사선 치료 후 가임기 여성의 생식 기능에 크게 영향을 주지 않을 것으로 생각된다. 하지만 가임 여성의 경우에는 지속적인 불안감을 가지고 있으므로 이번 결과를 통한 데이터를 제시함으로써 심리적인 안정을 도모할 수 있을 것으로 사료된다.