DOI QR코드

DOI QR Code

Comparison of plan dosimetry on multi-targeted lung radiotherapy: A phantom-based computational study using IMRT and VMAT

  • Khan, Muhammad Isa (Department of Physics, University of Gujrat) ;
  • Rehman, Jalil ur (Department of Physics, Khawaja Farid University of Engineering and Information Technology) ;
  • Afzal, Muhammad (Department of Physics, The Islamia University Bahawalpur Pakistan) ;
  • Chow, James C.L. (Radiation Medicine Program, Princess Margaret Cancer Centre, University Health Network)
  • Received : 2021.12.13
  • Accepted : 2022.05.18
  • Published : 2022.10.25

Abstract

This work analyzed the dosimetric difference between the intensity modulated radiotherapy (IMRT), partial/single/double-arc volumetric modulated arc therapy (PA/SA/DA-VMAT) techniques in treatment planning for treating more than one target of lung cancer at different isocenters. IMRT and VMAT plans at different isocenters were created systematically using a Harold heterogeneous lung phantom. The conformity index (CI), homogeneity index (HI), gradient index (GI), dose-volume histogram and mean and maximum dose of the PTV were calculated and analyzed. Furthermore, the dose-volume histogram and mean and maximum doses of the OARs such as right lung, contralateral lung and non GTV were determined from the plans. The IMRT plans showed the superior target dose coverage, higher mean and maximum values than other VMAT techniques. PA-VMAT technique shows more lung sparing and DA-VMAT increases the V5/10/20 values of contralateral lung than other VMAT and IMRT techniques. The IMRT technique achieves highly conformal dose distribution to the target than other VMAT techniques. Comparing to the IMRT plans, the higher V5/10/20 and mean lung dose were observed in the contralateral lung in the DA-VMAT.

Keywords

Acknowledgement

Authors are thankful to the Higher Education Commission(HEC), Pakistan for providing a scholarship for Dr. Muhammad Isa Khan.

References

  1. B.E. Nelms, G. Robinson, J. Markham, K. Velasco, S. Boyd, S. Narayan, J. Wheeler, M.L. Sobczak, Variation in external beam treatment plan quality: an inter-institutional study of planners and planning systems, Pract. Radiat. Oncol. 2 (4) (2012) 296-305. https://doi.org/10.1016/j.prro.2011.11.012
  2. J.K. Kim, J.Y. Zhang, W. Wang, A. McCarthy, C. Oh, N.K. Gerber, A dosimetric comparison of IMRT and 3D-CRT using deep inspiratory breath hold (DIBH) and free-breathing (FB) techniques in gastric mucosa lymphoid tissue lymphoma (MALT), Int. J. Radiat. Oncol. Biol. Phys. 111 (3) (2021) e306-e307.
  3. K. Rastogi, S. Sharma, S. Gupta, N. Agarwal, S. Bhaskar, S. Jain, Dosimetric comparison of IMRT versus 3DCRT for post-mastectomy chest wall irradiation, Radiat. Oncol. J 36 (1) (2018) 71. https://doi.org/10.3857/roj.2017.00381
  4. L.T. Oanh, D.T. Tai, T.T. Loan, J.C. Chow, Calculation of Jaws-only IMRT (JOIMRT) dose distributions based on the AAPM TG-119 test cases using Monte Carlo simulation and Prowess Panther treatment planning system, Nucl. Eng. Technol. 53 (12) (2021) 4098-4105. https://doi.org/10.1016/j.net.2021.07.005
  5. J.K. Kim, J.Y. Zhang, W. Wang, A. McCarthy, C. Oh, N.K. Gerber, A dosimetric comparison of IMRT and 3D-CRT using deep inspiratory breath hold (DIBH) and free-breathing (FB) techniques in gastric mucosa lymphoid tissue lymphoma (MALT), Int. J. Radiat. Oncol. Biol. Phys. 111 (3) (2021) e306-e307.
  6. L.T. Oanh, D.T. Tai, T.T.H. Loan, J.C.L. Chow, Calculation of Jaws-only IMRT (JOIMRT) dose distributions based on the AAPM TG-119 test cases using Monte Carlo simulation and Prowess Panther treatment planning system, Nucl. Eng. Technol. 53 (12) (2021) 4098-4105. https://doi.org/10.1016/j.net.2021.07.005
  7. M. Isa, R. Jiang, A. Kiciak, J. Rehman, M. Afzal, J.C.L. Chow, Dosimetric and radiobiological characterizations of prostate IMRT and VMAT: a singleinstitution review of 90 cases, J. Med. Phys. 41 (2016) 162-168. https://doi.org/10.4103/0971-6203.189479
  8. A. Rashid, Z. Ahmad, M.A. Memon, A.S. Hashim, Volumetric Modulated Arc Therapy (VMAT): a modern radiotherapy technique-A single institutional experience, Pakistan J. Med. Sci. 37 (2) (2021) 355.
  9. J. Rehman, R.C. Tailor, M. Isa, M. Afzal, J.C.L. Chow, G.S. Ibbott, Evaluations of secondary cancer risk in spine radiotherapy using 3DCRT, IMRT and VMAT, Med. Dosim. 40 (2015) 70-75. https://doi.org/10.1016/j.meddos.2014.10.003
  10. J.C.L. Chow, R. Jiang, Comparison of dosimetric variation between prostate IMRT and VMAT due to patient's weight loss: patient and phantom study, Rep. Practical Oncol. Radiother. 18 (1) (2013) 272-278, 2013. https://doi.org/10.1016/j.rpor.2013.05.003
  11. B. Suresh, Rana. Volumetric intensity modulated arc therapy in lung cancer: current literature review, Clin. Can. Invest. J. 2 (2013) 9-13. https://doi.org/10.4103/2278-0513.110758
  12. Q. Peng, J. Shi, J. Zhang, Q. Li, Z. Li, Q. Zhang, Y. Peng, L. Chen, Comparison of combinations of irradiation techniques and jaw conditions in intensitymodulated radiotherapy for lung cancer, J. Appl. Clin. Med. Phys. 22 (10) (2021) 178-189.
  13. C.L. Ong, W.F. Verbakel, J.P. Cuijpers, B.J. Slotman, F.J. Lagerwaard, S. Senan, Stereotactic radiotherapy for peripheral lung tumors: a comparison of volumetric modulated arc therapy with 3 other delivery techniques, Radiother. Oncol. 97 (2010) 437-442. https://doi.org/10.1016/j.radonc.2010.09.027
  14. K.T. Afrin, S. Ahmad, Is IMRT or VMAT superior or inferior to 3D conformal therapy in the treatment of lung cancer? A brief literature review, J. Radiother. Pract. (2021) 1-5.
  15. W.F. Verbakel, E. van Reij, I. Ladenius-Lischer, J.P. Cuijpers, B.J. Slotman, S. Senan, Clinical application of a novel hybrid intensity-modulated radiotherapy technique for stage III lung cancer and dosimetric comparison with four other techniques, Int. J. Radiat. Oncol. Biol. Phys. 83 (2012) e297-e303. https://doi.org/10.1016/j.ijrobp.2011.12.059
  16. Z. Ouyang, T. Zhuang, G. Marwaha, M.D. Kolar, P. Qi, G.M. Videtic, K.L. Stephans, P. Xia, Evaluation of automated treatment planning and organ dose prediction for lung stereotactic body radiotherapy, Cureus 13 (10) (2021 Oct).
  17. A. Holt, C. van Vliet-Vroegindeweij, A. Mans, J.S. Belderbos, E.M. Damen, Volumetric-modulated arc therapy for stereotactic body radiotherapy of lung tumors: a comparison with intensity-modulated radiotherapy techniques, Int. J. Radiat. Oncol. Biol. Phys. 81 (2011) 1560-1567. https://doi.org/10.1016/j.ijrobp.2010.09.014
  18. G.G. Zhang, L. Ku, T.J. Dilling, C.W. Stevens, R.R. Zhang, W. Li, V. Feygelman, Volumetric modulated arc planning for lung stereotactic body radiotherapy using conventional and unflattened photon beams: a dosimetric comparison with 3D technique, Radiat. Oncol. 6 (2011) 152. https://doi.org/10.1186/1748-717X-6-152
  19. Temelli O, M. Demirtas, B.T. Ugurlu, Dosimetric comparison of helical tomotherapy and hybrid (3DCRT-VMAT) technique for locally advanced non-small cell lung cancer, J. Radiother. Pract. 20 (3) (2021) 300-305. https://doi.org/10.1017/S1460396920000357
  20. C.B. Chiarot, J.H. Siewerdsen, T. Haycocks, D.J. Moseley, D.A. Jaffray, An innovative phantom for quantitative and qualitative investigation of advanced x-ray imaging technologies, Phys. Med. Biol. 50 (2005) N287-N297. https://doi.org/10.1088/0031-9155/50/21/N01
  21. I. Paddick, B. Lippitz, A simple dose gradient measurement tool to complement the conformity index, J. Neurosurg. 105 (2006) 194-201. https://doi.org/10.3171/sup.2006.105.7.194
  22. X. Jiang, T. Li, Y. Liu, L. Zhou, Y. Xu, X. Zhou, Y. Gong, Planning analysis for locally advanced lung cancer: dosimetric and efficiency comparisons between intensity-modulated radiotherapy (IMRT), single-arc/partial-arc volumetric modulated arc therapy (SA/PA-VMAT), Radiat. Oncol. 6 (2011) 140. https://doi.org/10.1186/1748-717X-6-140
  23. M. Rao, W. Yang, F. Chen, K. Sheng, J. Ye, V. Mehta, D. Shepard, D. Cao, Comparison of Elekta VMAT with helical tomotherapy and fixed field IMRT: plan quality, delivery efficiency and accuracy, Med. Phys. 37 (2010) 1350-1359. https://doi.org/10.1118/1.3326965
  24. S.D. McGrath, M.M. Mathuszak, D. Yan, L.L. Kestin, A.A. Martinez, I.S. Grills, Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: a dosimetric and treatment efficiency analysis, Radiother. Oncol. 95 (2010) 153-157. https://doi.org/10.1016/j.radonc.2009.12.039