• 제목/요약/키워드: dose control

검색결과 4,584건 처리시간 0.032초

Administrative dose control for occupationally-exposed workers in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Jung, Yoonhee;Kim, Jeong Mi;Cho, Moonhyung
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.351-356
    • /
    • 2021
  • Korean nuclear power plants (NPPs) have various radiation protection programs to attain radiation exposure as low as reasonably achievable (ALARA). In terms of ALARA, this paper provides a comprehensive overview of administrative dose control for occupationally-exposed workers in Korean NPPs. In addition to dose limits, administrative dose constraints are implemented to resolve an inequity of radiation exposure in which some individuals in NPPs receive relatively higher doses than others. Occupational dose constraints in Korean NPPs are presented in this paper with the background of how those values were determined. For pressurized water reactors, 80% and 90% of the annual average limit for an effective dose, 20 mSv/y, are set as the primary and secondary dose constraints, respectively. Pressurized heavy water reactors (PHWRs) have also established the primary and secondary dose constraints corresponding to 70% and 80% of the effective dose limit, and additional constraints for tritium concentration are provided to control internal exposure in PHWRs. Follow-up measures for exceeding these administrative dose constraints are also introduced compared to exceeding the dose limits. Finally, analysis results of dose distributions show how the implementation of administrative dose constraints impacted the occupational dose distributions in Korean NPPs during the years 2009-2018.

최소 효과 용량을 정하는 축차 검정법 (Parametric Sequential Test Procedure to Find the Minimum Effective Dose)

  • 박수진;김동재
    • 응용통계연구
    • /
    • 제22권5호
    • /
    • pp.1033-1046
    • /
    • 2009
  • 신약 개발 연구 또는 임상시험에서 개발된 약이 0용량 대조군과 비교해 유의한 효과 차이가 있어 신체에 반응할 수 있는 최소 복용량을 결정하는데, 이 최소 복용량을 최소 효과 용량(Minimum Effective Dose; MED)이라 한다. 이 논문에서는 최소 효과 용량을 확인하기 위하여 업데이티드 대조군을 이용한 모수적 축차 검정법을 제안하였다. 또한 모의 실험을 통하여 기존의 검정법과 제안한 검정법의 실험유의수준(experimental significance level)과 검정력(power)을 비교하였다.

An Analysis on Treatment Schedule of Carbon Ion Therapy to Early Stage Lung Cancer

  • Sakata, Suoh;Miyamoto, Tadaaki;Tujii, Hirohiko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.174-176
    • /
    • 2002
  • A total of 134 patients with stage 1 of non-small cell lung cancer treated by carbon ion beam of HIMAC NIRS were investigated for control rate and delivered dose. The delivered dose of every patient was converted to biological effective dose (BED) of LQ model using fraction number, dose per fraction and alpha beta ratio which shows the maximum correlation between BED and tumor control. The BED of every patient was classified to establish a BED response curve for control. Assuming fraction numbers, dose response curves were introduced from BED response curve. The total doses to realize several control rates were obtained for the treatment of small fraction number.

  • PDF

2006년 인천의 한 유치원에서 발생한 홍역 유행 역학조사 (Epidemiological Investigation of a Measles Outbreak in a Preschool in Incheon, Korea, 2006)

  • 소재성;고운영;이동한;박광숙;이종구
    • Journal of Preventive Medicine and Public Health
    • /
    • 제41권3호
    • /
    • pp.153-158
    • /
    • 2008
  • Objectives : This study describes a plan that was designed to prevent a measles outbreak that showed a changed outbreak pattern. This study is based on the epidemiological investigation of a measles outbreak in a preschool in Incheon, Korea, 2006. Methods : The subjects were 152 students at a preschool where a measles outbreak occurred. A questionnaire survey was conducted and serological testing for measles-specific IgM was preformed. Results : Of the fifteen confirmed, identified cases, eleven patients had been vaccinated with one dose, one patient had received two doses and three patients were unvaccinated. The three unvaccinated cases consisted of one 5-year-old child, one 3-year-old child and one 16-month-old infant. For the cases with one dose of the vaccination, there were 11 cases, which consisted of six 5-year-old children, two 4-year-old children, two 3-year-old children and one 2-year-old child. The case with two doses of the vaccination was one 4-year-old child. The attack rate of measles was 100% in the 0-dose group, 11.2% in the 1-dose group and 2.0% in the 2-dose group. The vaccine's efficacy was 88.8% in the 1-dose group and 98.0% in the 2-dose group. The vaccine effectiveness for the 2-dose group was higher than that of the 1-dose group. Conclusions : High coverage with a 2-dose vaccination should be maintained, and the vaccination should be given at the suitable time to prevent a measles outbreak with a changed outbreak pattern.

디지털 방사선 시스템의 노출 유형에 따른 임상 적용 시 입사표면선량 및 Entropy 비교분석을 통한 자동노출제어장치의 유용성 평가 (Evaluation of Usefulness of Automatic Exposure Control (AEC) by Comparison Analysis of Entrance Surface Dose (ESD) and Entropy in Clinical Application of Digital Radiography (DR))

  • 최지안;황준호;이경배
    • 한국콘텐츠학회논문지
    • /
    • 제19권8호
    • /
    • pp.276-283
    • /
    • 2019
  • 본 연구는 자동노출제어장치(Automatic Exposure Control, AEC)와 수동노출 이용 시 입사표면선량(Entrance Surface Dose, ESD)과 Entropy를 분석하여 자동노출제어장치의 유용성에 대해 알아보고자 하였다. 실험방법은 Skull, Chest, Abdomen, Pelvis 부위에 대하여 란도팬텀(Rando Phantom)에 반도체 선량계를 위치시켜 선량을 측정하였고, 동시에 획득한 DICOM(Digital Imaging and Communications in Medicine) 파일을 Matlab으로 Entropy 분석을 하였다. 그 결과 자동노출제어장치 이용 시 모든 부위의 입사표면선량이 수동노출보다 낮았고 Entropy 수치는 높았으며, paired t-test는 p<0.05로 유의한 차이가 있음을 알 수 있었다. 결론적으로 자동노출제어장치의 사용은 X선 검사 시 발생할 수 있는 불필요한 방사선량과 정보의 손실량을 줄여서 피폭선량과 영상 화질의 최적화에 기여할 수 있는 유용한 방법이 될 수 있다.

제조사별 다중 검출기 컴퓨터단층촬영 장비의 관전류 자동노출조절 기법의 방사선량 감소 평가 (Evaluation of Radiation Dose Reduction from the Automatic Exposure Control Technique in Different Manufactures Multi-Detector Computed Tomography)

  • 김영옥;성열훈
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2011년도 추계학술대회
    • /
    • pp.563-571
    • /
    • 2011
  • The purpose of the study was to evaluation of the radiation dose reduction using various automatic exposure control (AEC) systems in different manufactures multi-detector computed tomography (MDCT). We used three different manufacturers for the study: General Electric Healthcare, Philips Medical systems and Siemens Medical Solutions. The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using body phantom. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the GE, 58.2% in the Philips, and 48.6% in the Siemens. This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

  • PDF

Optimal Scheduling of Drug Treatment for HIV Infection: Continuous Dose Control and Receding Horizon Control

  • Hyungbo Shim;Han, Seung-Ju;Chung, Chung-Choo;Nam, Sang-Won;Seo, Jin-Heon
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권3호
    • /
    • pp.282-288
    • /
    • 2003
  • It is known that HIV (Human Immunodeficiency Virus) infection, which causes AIDS after some latent period, is a dynamic process that can be modeled mathematically. Effects of available anti-viral drugs, which prevent HIV from infecting healthy cells, can also be included in the model. In this paper we illustrate control theory can be applied to a model of HIV infection. In particular, the drug dose is regarded as control input and the goal is to excite an immune response so that the symptom of infected patient should not be developed into AIDS. Finite horizon optimal control is employed to obtain the optimal schedule of drug dose since the model is highly nonlinear and we want maximum performance for enhancing the immune response. From the simulation studies, we found that gradual reduction of drug dose is important for the optimality. We also demonstrate the obtained open-loop optimal control is vulnerable to parameter variation of the model and measurement noise. To overcome this difficulty, we finally present nonlinear receding horizon control to incorporate feedback in the drug treatment.

Development of PC-based Radiation Therapy Planning System

  • Suh, Tae-Suk;P task group, R-T
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.121-122
    • /
    • 2002
  • The main principle of radiation therapy is to deliver optimum dose to tumor to increase tumor cure probability while minimizing dose to critical normal structure to reduce complications. RTP system is required for proper dose plan in radiation therapy treatment. The main goal of this research is to develop dose model for photon, electron, and brachytherapy, and to display dose distribution on patient images with optimum process. The main items developed in this research includes: (l) user requirements and quality control; analysis of user requirement in RTP, networking between RTP and relevant equipment, quality control using phantom for clinical application (2) dose model in RTP; photon, electron, brachytherapy, modifying dose model (3) image processing and 3D visualization; 2D image processing, auto contouring, image reconstruction, 3D visualization (4) object modeling and graphic user interface; development of total software structure, step-by-step planning procedure, window design and user-interface. Our final product show strong capability for routine and advance RTP planning.

  • PDF

과배란유도에서 GnRH Antagonist (Cetrorelix) Single 및 Multiple Dose Protocol의 임상적 효용성에 관한 연구 (A Study of Clinical Efficacy of GnRH Antagonist (Cetrorelix) Single and Multiple Dose Protocol for Controlled Ovarian Hyperstimulation)

  • 고상현;김동호;배도환;이상훈
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제29권4호
    • /
    • pp.259-267
    • /
    • 2002
  • Objective: This study was performed to compare the clinical outcomes of GnRH antagonist (Cetrorelix) single dose and multiple dose protocols for controlled ovarian hyperstimulation with GnRH agonist long protocol. Materials and Method: From September 2001 to March 2002, 48 patients (55 cycles) were performed controlled ovarian hyperstimulation for ART using by either GnRH antagonist and GnRH agonist. Single dose of 3 mg GnRH antagonist was administered in 15 patients (17 cycles, single dose group) at MCD #8 and multiple dose of 0.25 mg of GnRH antagonist was administered in 15 patients (18 cycles, multiple dose group) from MCD #7 to hCG injection day. GnRH agonist was administered in 18 patients (20 cycles, control group) by conventional GnRH agonist long protocol. We compared the implantation rate, number of embryos, and clinical pregnancy rate among three groups. Student-t test and Chi-square were used to determine statistical significance. Statistical significance was defined as p<0.05. Results: There were no significant differences in ampules of used gonadotropins, number of mature oocytes, obtained embryos between single and multiple dose group, but compared with control group, ampules of used gonadotropins, number of mature oocytes, obtained embryos were decreased significantly in both groups. Clinical pregnancy rate and implantation rate were not different in three groups. There were no premature LH surge and ovarian hyperstimulation syndrome in three groups. Multiple pregnancy were occurred 1 case in multiple dose group and 2 case in control group. Conclusions: GnRH antagonist is a safe, effective, and alternative method in the controlled ovarian hyperstimulation compared with GnRH agonist. Clinical outcomes and efficacy of both single and multiple dose protocol are similar between two groups.

Optimal Scheduling of Drug Treatment for HIV Infection;Continuous Dose Control and Receding Horizon Control

  • Shim, H.;Han, S.J.;Jeong, I.S.;Huh, Y.H.;Chung, C.C.;Nam, S.W.;Seo, J.H.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1951-1956
    • /
    • 2003
  • It is known that HIV (Human Immunodeficiency Virus) infection, which causes AIDS after some latent period, is a dynamic process that can be modeled mathematically. Effects of available anti-viral drugs, which prevent HIV from infecting healthy cells, can also be included in the model. In this paper we illustrate control theory can be applied to a model of HIV infection. In particular, the drug dose is regarded as control input and the goal is to excite an immune response so that the symptom of infected patient should not be developed into AIDS. Finite horizon optimal control is employed to obtain the optimal schedule of drug dose since the model is highly nonlinear and we want maximum performance for enhancing the immune response. From the simulation studies, we find that gradual reduction of drug dose is important for the optimality. We also demonstrate the obtained open-loop optimal control is vulnerable to parameter variation of the model and measurement noise. To overcome this difficulty, we finally present nonlinear receding horizon control to incorporate feedback in the drug treatment.

  • PDF