• Title/Summary/Keyword: doppler ultrasound

Search Result 147, Processing Time 0.026 seconds

Comparison of Cerebral Blood Flow between Patients with Metabolic Syndrome and Normal Group to Evaluate Diagnostic Value of Transcranial Doppler Ultrasound (대사증후군 환자군과 정상군의 뇌혈류 측정 비교를 통한 뇌졸중 위험인자에 대한 TCD의 진단적 가치 고찰)

  • Um, Eun-Jin;Park, Woo-Rham;Kim, Ju-Sung;Lee, Beom-Joon;Na, Byung-Jo
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.14 no.2
    • /
    • pp.85-100
    • /
    • 2010
  • Objectives: The purpose of this study was to evaluate diagnostic value of Transcranial Doppler Ultrasound about risk factor of stroke by comparing blood flow between patients with metabolic syndrome(MS group) and Normal group. Methods: 62 metabolic syndrome patients and 106 healthy adults were selected who had no cerebrovascular diseases, cardiovascular diseases and other systemic diseases. We measured the mean velocity(Vm), peak systolic velocity(Vs) and pulsatility index(PI) of MCA, ACA, PCA, VA, ICA in two groups using TCD. All subjects were divided by gender and age. Results: In comparing Ms group with normal group, Vm in the MCA, ACA, PCA, ICA and Vs in the MCA, ICA were lower in MS group. In all vessels, PI of MS group were higher than that of Normal group. In all vessels, Vm and Vs revealed negative correlation with age and PI revealed positive correlation with age. In 20-39 year olds, there was decrease in the Vs and Vm and increase of PI of MS group in comparison with normal group. There was significant difference in the Vm of PCA, ICA, Vs of MCA, PCA, ICA and PI of MCA, ACA. In 40-59 year olds, Vm in the MCA, ACA, ICA and Vs in the MCA, ACA were lower in MS group. PI in the MCA, ACA, PCA, ICA were higher in MS group. In 60-79 year olds, Vm of MCA, PCA, ICA was decreased in MS group than Normal group with no statistical signification. Vs in the MCA was lower and PI in the PCA was higher in MS group. In male, Vm of PCA and Vs of MCA were lower and PI of MCA, ACA, PCA, ICA were higher in MS group. In female, Vm of MCA, PCA, ICA and Vs of MCA, ICA were lower and PI of ACA, PCA, VA, ICA were higher in MS group. Conclusions: The significant difference in Vm, Vs, PI between MS group and normal group suggests hemodynamic disorder. Screening and prognosing high risk group can be done through TCD and this can be used to prevent stroke. More detailed study will be needed.

Ultrasonographic Resistive Index of the Cranial Pancreaticoduodenal Artery in Normal Conscious Dogs (정상견에서 전방 췌장십이장 동맥의 초음파학적 혈관 저항지수)

  • Eom, Ki-Dong;Lee, Hae-oon;Seong, Yun-sang;Lee, Jeong-min;Lee, Jong-won;Oh, Tae-ho
    • Journal of Veterinary Clinics
    • /
    • v.20 no.3
    • /
    • pp.274-277
    • /
    • 2003
  • The purpose of this study was to determine the range of resistive index(RI) of the cranial pancreaticoduodenal artery(cPDA) in the normal dog's and to assess the possibility of clinical application of RI for diagnosing a pancreatitis. Five patients with acute pancreatitis and 17 healthy adult beagle dogs were used. Duplex color Doppler ultrasonographic examination was performed by using a real-time scanner with 11-MHz linear-array transducer. The dogs were restrained in dorsal recumbency without the use of chemical agent. The mean RI of the normal pancreas(0.63$\pm$0.04) was significantly(t = 5.79, p = 0.001) different from acute pancreatitis dog(0.75$\pm$0.04). Duplex color Doppler ultrasonography was an useful technique for detecting and measuring RI of the cPDA. The evaluation of RI of the cPDA may be a valuable supportive diagnostic procedure for evaluating the pancreatitis or suspected in dogs.

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

Image Enhancement for Sub-Harmonic Phased Array by Removing Surface Wave Interference with Spatial Frequency Filter

  • Park, Choon-Su;Kim, Jun-Woo;Cho, Seung Hyun;Seo, Dae-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • Closed cracks are difficult to detect using conventional ultrasonic testing because most incident ultrasound passes completely through these cracks. Nonlinear ultrasound inspection using sub-harmonic frequencies a promising method for detecting closed cracks. To implement this method, a sub-harmonic phased array (PA) is proposed to visualize the length of closed cracks in solids. A sub-harmonic PA generally consists of a single transmitter and an array receiver, which detects sub-harmonic waves generated from closed cracks. The PA images are obtained using the total focusing method (TFM), which (with a transmitter and receiving array) employs a full matrix in the observation region to achieve fine image resolution. In particular, the receiving signals are measured using a laser Doppler vibrometer (LDV) to collect PA images for both fundamental and sub-harmonic frequencies. Oblique incidence, which is used to boost sub-harmonic generation, inevitably produces various surface waves that contaminate the signals measured in the receiving transducer. Surface wave interference often degrades PA images severely, and it becomes difficult to read the closed crack's position from the images. Various methods to prevent or eliminate this interference are possible. In particular, enhancing images with signal processing could be a highly cost-effective method. Because periodic patterns distributed in a PA image are the most frequent interference induced by surface waves, spatial frequency filtering is applicable for removing these waves. Experiments clearly demonstrate that the spatial frequency filter improves PA images.

Clinical Application of an Image-Guided Intervention in Three Dogs

  • Choi, Minsik;Kwon, Dohoon;Ahn, Jisoo;Ko, Minjung;Ahn, Jiyoung;Jung, Joohyun;Kim, Hakhyun;Kang, Ji-Houn;Chang, Dongwoo
    • Journal of Veterinary Clinics
    • /
    • v.37 no.2
    • /
    • pp.100-105
    • /
    • 2020
  • A 9-month-old, 11.3 kg, intact, male, mixed-breed dog was referred for treatment of cor triatriatum dexter (CTD); a 5-month-old, 1.9 kg, intact, male Maltese for pulmonic stenosis (PS); and a 3-year-old, 6.62 kg, intact, female West Highland white terrier for esophageal stricture with regurgitation. A balloon catheter intervention was performed in the dog with CTD, and subsequent color Doppler ultrasound and abdominal ultrasound showed normal blood flow across the perforated membrane dividing the right atrium and the disappearance of the severe ascites present before treatment. Balloon catheter intervention in the dog with PS reduced the blood flow through the stenosis from 5.82 m/s to 3.97 m/s. In the dog with esophageal stricture, balloon catheter intervention widened the esophagus and no subsequent regurgitation was observed. Balloon catheter intervention is an interventional radiology procedure that represents a definitive treatment option for various stenotic lesions in dogs, including CTD, PS, and esophageal stricture. Although interventional radiology procedures for these diseases have already been reported, details of procedures and successful outcome have not been reported in Korea.

Shear-wave elasticity imaging with axial sub-Nyquist sampling (축방향 서브 나이퀴스트 샘플링 기반의 횡탄성 영상 기법)

  • Woojin Oh;Heechul Yoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.42 no.5
    • /
    • pp.403-411
    • /
    • 2023
  • Functional ultrasound imaging, such as elasticity imaging and micro-blood flow Doppler imaging, enhances diagnostic capability by providing useful mechanical and functional information about tissues. However, the implementation of functional ultrasound imaging poses limitations such as the storage of vast amounts of data in Radio Frequency (RF) data acquisition and processing. In this paper, we propose a sub-Nyquist approach that reduces the amount of acquired axial samples for efficient shear-wave elasticity imaging. The proposed method acquires data at a sampling rate one-third lower than the conventional Nyquist sampling rate and tracks shear-wave signals through RF signals reconstructed using band-pass filtering-based interpolation. In this approach, the RF signal is assumed to have a fractional bandwidth of 67 %. To validate the approach, we reconstruct the shear-wave velocity images using shear-wave tracking data obtained by conventional and proposed approaches, and compare the group velocity, contrast-to-noise ratio, and structural similarity index measurement. We qualitatively and quantitatively demonstrate the potential of sub-Nyquist sampling-based shear-wave elasticity imaging, indicating that our approach could be practically useful in three-dimensional shear-wave elasticity imaging, where a massive amount of ultrasound data is required.

A study on the real time fetal heart rate monitoring system by high resolution pitch detection algorithm (고해상 피치 검출 알고리듬을 적용한 실시간 태아 심음 감시시스템에 관한 연구)

  • 이응구;이두수
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.2
    • /
    • pp.175-182
    • /
    • 1995
  • Despite the simplicity of processing, a conventional autocorrelation function (ACF) method for the precise determination of fetal heart rate (FHR) has many problems. In case of weak or noise corrupted Doppler ultrasound signal, the ACF method is very sensitive to the threshold level and data window length. It is very troublesome to extract FHR when there is a data loss. To overcome these problems, the high resolution pitch detection algorithm was adopted to estimate the FHR. This method is more accurate, robust and reliable than the ACF method. With a lot of calculation, however, it is impossible to process real time FHR estimation. This paper is presented a new FHR estimation algorithm for real time processing and studied the real time FHR monitoring system by high resolution pitch detection algorithm.

  • PDF

The Effects of Myofascial Relaxation on Blood Flow Velocity of the Cranial Artery and Pain Level in Cervicogenic Headache Patients (근막이완술이 경추성 두통환자의 뇌혈류와 통증수준에 미치는 영향)

  • Lee, Joon-Hee;Kang, Da-Haeng;Kang, Jeong-Il
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.5
    • /
    • pp.49-56
    • /
    • 2010
  • Purpose: The aim of this study was to evaluate a possible role for cranial artery velocity in cervicogenic headache. Methods: We studied 13 patients with cervicogenic headaches (M=9, F=4, age=$24.50{\pm}3.50\;y$) these were compared to 20 normal subjects (M=10, F=10, age=$23.30{\pm}2.90\;y$). Cervicogenic headache patients were divided into two groups (a myofascial relaxation group, a placebo group). Pain levels were measured using a visual analog scale (VAS). Transcranial Doppler (TCD) ultrasound recordings were used to measure blood flow velocity in the cranial artery. Results: Cervicogenic headache patients exhibited a significantly lower blood flow velocity in the middle cerebral artery. The patients who received an intervention had a significantly higher blood flow velocity in the left middle cerebral artery, right vertebral artery and basilar artery. Compared to the placebo group, the myofascial relaxation group exhibited a significantly decreased level of pain. Conclusion: Cervicogenic headache is pain referred to the head from a source in the cervical spine. Manual therapy affect to cervical spine and soft tissue as well as the passage of these vessels and nerves to recover because it is thought to be able to help.

Maximum exercise in 20 men Common carotid artery blood flow velocity impact (20대 남성에서 최대운동이 뇌로가는 혈관인 총경동맥 혈류 속도에 미치는 영향)

  • Kim, Ji-Won
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.5-12
    • /
    • 2009
  • Arterial blood from the heart chonggyeong passed directly to the cerebral arteries and the blood circulation is important, especially in arteries that prevent blood flow there are several variables. Among the variables the average flow velocity, pulse index, and blood flow resistance and which variables, double maekbakjisuna systolic and diastolic blood flow resistance index at the maximum rate and blood pressure associated with this because they are important variables, The change of variables such as speed noehyeolryu There are observations about the non-invasive ultrasound measurements using Doppler noehyeolryu uses. Up to 20 men in the exercise of noeroganeun hyeolryuin chonggyeong arteries to increase blood flow rates can be found.

  • PDF

A Case of Infantile Hemangioendothelioma of the Liver Treated with Hepatic Embolization and Lobectomy (간동맥 색전술과 간엽 절제술로 치료한 영아 간내 혈관내피종 1례)

  • Kim, Jae Seon;Moon, Soo Kyung;Yoon, Hye Seon;Lee, Tae Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.660-664
    • /
    • 2005
  • Infantile hemangioendothelioma(IHE) of the liver is the most common vascular tumor in infants before the age of 6 months. It is a histologically benign tumor with potentially life-threatening complications. The clinical manifestations are variable, ranging from asymptomatic forms to intractable high-output heart failure. In addition, abdominal mass, intraperitoneal hemorrhage due to rupture of mass, respiratory distress, hematologic abnormalities and jaundice can occur. Diagnostic work-up is through doppler ultrasound sonography, computed tomography scan, magnetic resonance imaging and angiography. Treatment consists of medical treatment, interventional therapy, surgical resection and liver transplantation. We experienced symptomatic IHE in a premature neonate who presented with high output heart failure and respiratory distress. Initial medical treatment and steroid therapy failed to improve his condition. Coil embolization of left hepatic artery resulted in improvement of respiratory symptoms. However, a left lobectomy was performed because the mass size was not decreased with development of collateral vessels. The infant was well, after a successful discharge from the hospital.