• 제목/요약/키워드: district heating system

검색결과 235건 처리시간 0.026초

지역난방수 환수 승온방식의 태양열 지역냉난방 시스템 분석 (A Study on the Design and Analysis of District Solar Heating and Cooling System with Preheating of Returning District Heating Water)

  • 백남춘;신우철;이진국;윤응상;윤석만
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.433-437
    • /
    • 2005
  • This study was carried out the design and analysis of solar thermal system with preheating of returning district heating water for the Chung-ju district heating and cooling system. Two different types of solar collectors are used for this system. TRNSYS simulation program was used for the analysis. As a results, the solar system efficiency is $35.8\%$ for the plate type and $45.1\%$ for the evacuated type solar collector in the case of $50^{\circ}C$ for the returning district heating water temperature. The returning district heating water temperature is on of the very important factors that is influence on the system efficiency. So the effect of the returning district heating water temperature on the system efficiency is analyzed in this study.

  • PDF

중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석 (Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System)

  • 김규생;이상혁;홍경표;원영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

급탕 2단열교환방식 지역난방 열사용시설의 급탕부하 분배에 관한 연구 (Distribution of Hot Tap Water Load for District Heating Substation with Hot Tap Water 2-Stage Heat Exchanger)

  • 정동화;김주완;백영진;이영수;정대헌
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.297-302
    • /
    • 2011
  • According to the standards for district heating substation established by Korea District Heating Corporation, water heating supply systems at over 150 Mcal/h capacity must employ the 2-stage heat exchanger that improves the system efficiency by reusing the heat included in the return water of district heating system already used for space heating. In this paper, the operating characteristics of the system in accordance with the load distribution of two heat exchangers for pre-heating and re-heating cold city water are investigated. The results including mass flow rate, return temperature etc. help to manage district heating system economically.

중앙난방방식을 지역난방과 소형열병합난방 방식으로 전환 시 경제성 비교 분석 (Analysis of the Economic Efficiency of the District Heating and Gas Engine Co-Generation System Compared with the Central Heating System)

  • 김규생
    • 설비공학논문집
    • /
    • 제27권10호
    • /
    • pp.544-551
    • /
    • 2015
  • This study was conducted to determine the LCC of apartment complexes with district heating and a cogeneration system. For the purpose of analyzing LCC according to the size of the apartment complex, 500, 1,500, and 4,000-unit model apartments were selected. Analysis was performed on the design of the heating system and the life cycle cost including total construction cost, maintenance and operation cost for the duration of the project period (15 years). According to the calculated results, 1) The initial cost of the cogeneration system for 500, 1,500, and 4,000-unit apartments is higher than that of the district heating system by 20%, 13%, and 12%, respectively. 2) In the case of the cogeneration system, the payback period by electric generation was found to be 5.21, 4.92 and 4.47 years, and saving cost was calculated to be 29 billion won, 94 billion won and 262 billion won after the payback period for 500, 1,500, and 4,000-unit apartments, respectively. 3) The LCC values of the cogeneration system were 1.12, 1.07 and 1.06 times larger than those of the district system according to the size of the apartment complex. In this study, the district heating system was found to be more efficient than the cogeneration system in terms of LCC reduction. 4) District heating is affected by fuel bills, so energy efficiency should be improved through recovering waste heat (incineration heat, etc.). Also, district cooling should be provided according to heat use to keep the temperature high in winter and low in summer.

지역난방설비를 위한 IoT 기반 원격 관리 시스템 구축에 대한 연구 (A Study on Establishment of the IoT-Based Remote Management System for District Heating Facilities)

  • 김준혁;이상학;김병민
    • 한국통신학회논문지
    • /
    • 제42권3호
    • /
    • pp.698-701
    • /
    • 2017
  • 현재 우리나라의 130만여 가구는 지역난방 열에너지를 사용하고 있다. 이러한 지역난방 열에너지 시스템은 한국지역난방공사에서 공급하는 1차측과 이를 개별 가구에 공급하는 2차측으로 구분되어 있다. 본 논문에서는 체계적이지 않고, 전문인력에 대한 의존도가 높은 2차측의 관리 및 유지보수 시 문제점을 보완하기 위한 IoT 기반 열에너지 원격 관리시스템의 구축에 대하여 논의한다.

대기오염 방지대책으로서 지역난방의 효과분석에 관한 연구 (A Study on the Effects of the District Heating as an Air Pollution Control Strategy)

  • 전의찬;김정욱
    • 한국대기환경학회지
    • /
    • 제6권1호
    • /
    • pp.51-56
    • /
    • 1990
  • This Study shows the effect of the district heating on the $SO_2$ concentration reduction. In order to analyze the effect of the district heating, three alternatives were set up as follows; Alternative I represented present central heating system, and Alternative II and Alternative III represented district heating system of which the scale were different from. The concludions of this study are as follows; In case of the Alternative II and III, annual average $SO_2$ concentration are reduced by 9.0% and 14.6% respectively, and winter season $SO_2$ concentrations are reduced by 12.2% and 15.8% respectively, at the highest points. The average reduction rates of $SO_2$ concentration in the district heating area are about the same as the reduction rates at the highest points. Also, it was found that using the district heating system, the ground level $SO_2$ concentrations could be reduced within the area of 5 to 10 km radius.

  • PDF

Reduced LS-SVM을 이용한 지역난방 동절기 공동주택 난방부하의 모델링 (Modeling of Winter Time Apartment Heating Load in District Heating System Using Reduced LS-SVM)

  • 박영칠
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.283-292
    • /
    • 2015
  • A model of apartment heating load in a district heating system could be useful in the management and utilization of energy resources, since it could predict energy usage and so could assist in the efficient use of energy resources. The heating load in a district heating system varies in a highly nonlinear manner and is subject to many different factors, such as heating area, number of people living in that complex, and ambient temperature. Thus there are few published papers with accurate models of heating load, especially in domestic literature. This work is concerned with the modeling of apartment heating load in a district heating system in winter, using the reduced least square support vector machine (LS-SVM), and with the purpose of using the model to predict heating energy usage in domestic city area. We collected 23,856 pieces of data on heating energy usage over a 12-week period in winter, from 12 heat exchangers in five apartments. Half of the collected data were used to construct the heating load model, and the other half were used to test the model's accuracy. The model was able to predict the heating energy usage pattern rather accurately. It could also estimate the usage of heating energy within of mean absolute percentage error. This implies that the model prediction accuracy needs to be improved further, but it still could be considered as an acceptable model if we consider the nonlinearity and uncertainty of apartment heating energy usage in a district heating system.

지역난방의 환경개선효과 측정에 관한 연구 (A Study on the Enviromental Impact of District Heating System)

  • 손양훈;박주헌;조전혁
    • 자원ㆍ환경경제연구
    • /
    • 제10권3호
    • /
    • pp.367-386
    • /
    • 2001
  • In this paper we analyze the environmental advantages of district heating system. We construct three econometric models to analyze the energy consumption and economic cost as well as the emission of the major pollutants like $SO_x$, $NO_x$, DUST, and $CO_2$. As the size of heating supply is larger, the district heating system is evaluated to be better than other heating systems environmentally and costly in the long run. Especially, the district heating reduces $SO_x$ emission significantly when the size of heat production is large. But the advantages of district heating system are very sensitive to the fuel mix and heat source.

  • PDF

지역난방 태양열시스템의 열성능 해석 프로그램 개발 (Development of Thermal Performance Analysis Program of Solar Heating System for District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.64-69
    • /
    • 2008
  • In this study the thermal performance and economic analysis program of solar heating system for district heating was developed. This program, named SOLAN-DHS and based on TRNSYS, consisted of four modules like as user's interface for system input/output, library, and utilities and a calculating engine. SOLAN-DHS simplifies user's input data through the database of most system engineering data including weather data of 17 areas in Korea. Five different types of solar systems which can be applicable to district heating system were presented in this program. Due to the user-friendly layout, all design parameters can be changed quickly and easily for the influence on system efficiency. The reliability of SOLAN-DHS was finally verified by the experiments.

지역난방용 태양열시스템 (Solar District Heating System)

  • 백남춘;이진국;윤응상;윤석만;신우철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF